
This 10G-SFPP-TWX-P-0501 compatible DAC cable provides a 10G direct connection for Brocade equipment in a fixed 5m (16ft) configuration. The SFP+ to SFP+ assembly integrates both ends and the cable, giving data-center designers one defined product to evaluate for reach, rack layout, airflow and host compatibility.
OEM Part Number: 10G-SFPP-TWX-P-0501HT Part Number: 10G-SFPP-TWX-P-0501
| HT Part Number | 10G-SFPP-TWX-P-0501 |
|---|---|
| Brocade Compatible | SFP-H10GB-CU5M |
| Manufacturer | HT |
| Connector Type | SFP+ to SFP+ |
| Max Data Rate | 10Gbps |
| Media | Copper |
| Power Supply | 3.3V |
| Minimum Bend Radius | 30mm |
| Wire AWG | 24AWG |
| Cable Length | 5m (16.4ft) |
| Jacket Material | PVC (OFNR) |
| Cable Type | Passive Twinax |
| Temperature | 0 to 70°C (32 to 158°F) |
| Power Consumption | ≤0.1W |
| Application | 10G Ethernet |
| Protocols | 1x InfiniBand QDR, DDR, SDR, 10 Gigabit Ethernet, Fibre Channel |
The rated power consumption is ≤0.1W. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.
10G-SFPP-TWX-P-0501 occupies the middle of this family between 10G-SFPP-TWX-P-0301 at 3m (10ft) and XBR-TWX-0701 at 7m (23ft). It adds 2m over the shorter option for extra routing clearance, while the next longer version adds another 2m. Measure the managed path and choose this version when its reach is sufficient without creating the slack associated with the longer assembly.
Select the assembly by both reach and rack layout. A direct connection removes separate module-and-patch-cord interfaces, but it still needs a bend-safe pathway and clear connector access. Keep cable bundles from blocking front-panel airflow, account for the listed interface power where applicable and choose a length that supports maintenance without leaving an unmanaged coil. For this assembly, the listed conductor specification is 24AWG; the minimum bend radius is 30mm; the stated power consumption is ≤0.1W; the jacket material is PVC (OFNR).
This assembly uses 24AWG conductors, PVC (OFNR) jacket, minimum bend radius 30mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.
The intended application is 10G Ethernet. Listed interface and protocol references include 1x InfiniBand QDR, DDR, SDR, 10 Gigabit Ethernet, Fibre Channel. Confirm that the host firmware and port configuration support the same operating mode.
A passive DAC has no separate optical conversion stage. Its low-power, low-latency operation is useful for short equipment links, but the assembly must remain within the length and signaling mode accepted by both hosts.
The 5m (16ft) length gives 10G-SFPP-TWX-P-0501 more freedom for adjacent-rack and row-end deployments. Longer copper runs need particular attention to routing weight and bend control; the DAC specification and host support must still match the intended link.
Each cable receives connector inspection and a functional link check before it is coiled with bend-safe slack and packed. Protective materials shield the connector housings during transport. Rack or project labels are available to keep length, part number and installation destination aligned. Volume orders can include customer references on the labels and carton list.
Provide the OEM reference, HT part number, fixed length and quantity, together with the intended host interfaces. Rack-based quantities and packaging instructions can be included for larger deployments. Other lengths are separate products and should be entered on their own order lines. This page’s fixed configuration is 5m (16ft); another length must be quoted under its corresponding part number.
Compatibility confirmation combines host identification with actual link establishment and diagnostic checks. The assembly is prepared for the stated OEM reference rather than selected only by connector shape. For a new data-center deployment, the equipment model, port mode and software release provide the most useful basis for a pre-order review. Where supported by the host, link stability and diagnostic indications are reviewed together with the established link.
No. It is an HT-manufactured compatible alternative for equipment that specifies Brocade 10G-SFPP-TWX-P-0501.
Not necessarily. Both hosts must support the stated rate, identification, lane mapping and any required breakout configuration; mechanical compatibility alone is insufficient.
Provide the equipment manufacturer, model, port type, hardware revision and software release, together with the OEM reference, required length and quantity.
Protect both connector ends, keep the cable in a loose bend-safe coil and retain its part-number label so the length and compatibility identity remain traceable.
Available stock is generally dispatched within one to three working days after order confirmation, with production lead times advised for larger quantities. Delivery can be arranged by courier, air freight or sea freight, and goods may instead be handed to an appointed forwarder or shipped on the customer’s courier account.
800G TransceiversOSFP and QSFP-DD modules for AI data center networks
400G QSFP-DDSR8, DR4, FR4 and LR4 modules and cables
100G QSFP28SR4, CWDM4, LR4 and ER4 transceivers
DAC CablesDirect attach copper cables from 10G up to 800G
AOC CablesActive optical cables for rack-to-rack links
MTP/MPO Trunk Cables8F to 144F multi fiber trunk and harness cables
Fiber Patch CablesOS2, OM3, OM4, OM5 jumpers with LC, SC, FC, ST connectors
Armored Patch CablesStainless steel tube protected fiber patch cords
UAE office: Abu Dhabi,Al khaleej Al Arabi
Factory add: ZYT industrial area, Shiyan, Baoan district, Shenzhen, China 518000