This 10GB-C0.5-SFPP compatible DAC cable provides a 10G direct connection for Extreme Networks equipment in a fixed 0.5m (2ft) configuration. The SFP+ to SFP+ assembly integrates both ends and the cable, giving data-center designers one defined product to evaluate for reach, rack layout, airflow and host compatibility.
OEM Part Number: 10GB-C0.5-SFPPHT Part Number: 10GB-C0.5-SFPP
| HT Part Number | 10GB-C0.5-SFPP |
|---|---|
| Extreme Compatible | SFP-H10GB-CU50CM |
| Manufacturer | HT |
| Connector Type | SFP+ to SFP+ |
| Max Data Rate | 10Gbps |
| Media | Copper |
| Application | 10G Ethernet |
| Minimum Bend Radius | 23mm |
| Wire AWG | 30AWG |
| Cable Length | 0.5m (1.64ft) |
| Jacket Material | PVC (OFNR) |
| Cable Type | Passive Twinax |
| Temperature | 0 to 70°C (32 to 158°F) |
| Power Consumption | ≤0.1W |
| Power Supply | 3.3V |
| Protocols | 1x InfiniBand QDR, DDR, SDR, 10 Gigabit Ethernet, Fibre Channel |
The rated power consumption is ≤0.1W. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.
A passive DAC has no separate optical conversion stage. Its low-power, low-latency operation is useful for short equipment links, but the assembly must remain within the length and signaling mode accepted by both hosts.
The 0.5m (2ft) length is suited to closely aligned ports where excessive slack would obstruct airflow or complicate dressing. Measure the actual port-to-port path before choosing 10GB-C0.5-SFPP; even a short assembly must retain the specified bend radius and should never be pulled tight behind the equipment.
10GB-C0.5-SFPP is the shortest of 9 verified length options in this family. It is the preferred choice when the port positions are close and cable slack must be kept to a minimum. The next option is 10304 at 1m (3ft), adding 0.5m for a less direct routing path; selecting it unnecessarily would leave more cable to dress.
Select the assembly by both reach and rack layout. A direct connection removes separate module-and-patch-cord interfaces, but it still needs a bend-safe pathway and clear connector access. Keep cable bundles from blocking front-panel airflow, account for the listed interface power where applicable and choose a length that supports maintenance without leaving an unmanaged coil. For this assembly, the listed conductor specification is 30AWG; the minimum bend radius is 23mm; the stated power consumption is ≤0.1W; the jacket material is PVC (OFNR).
This assembly uses 30AWG conductors, PVC (OFNR) jacket, minimum bend radius 23mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.
The intended application is 10G Ethernet. Listed interface and protocol references include 1x InfiniBand QDR, DDR, SDR, 10 Gigabit Ethernet, Fibre Channel. Confirm that the host firmware and port configuration support the same operating mode.
Each cable receives connector inspection and a functional link check before it is coiled with bend-safe slack and packed. Protective materials shield the connector housings during transport. Rack or project labels are available to keep length, part number and installation destination aligned. Neutral packaging and customer-specific packing documentation are available on request.
Provide the OEM reference, HT part number, fixed length and quantity, together with the intended host interfaces. Rack-based quantities and packaging instructions can be included for larger deployments. Other lengths are separate products and should be entered on their own order lines. This page’s fixed configuration is 0.5m (2ft); another length must be quoted under its corresponding part number.
Compatibility confirmation combines host identification with actual link establishment and diagnostic checks. The assembly is prepared for the stated OEM reference rather than selected only by connector shape. For a new data-center deployment, the equipment model, port mode and software release provide the most useful basis for a pre-order review. The check includes link stability and diagnostic indications, followed by a final inspection of both ends.
No. It is an HT-manufactured compatible alternative for equipment that specifies Extreme Networks 10GB-C0.5-SFPP.
Only where both hosts explicitly support the complete interface and compatibility arrangement. Document each end and select the appropriate brand-specific product when required.
No. 10GB-C0.5-SFPP refers here to 0.5m (2ft). Every other verified length has a separate part number and page in the length list.
No. This is one complete direct-attach assembly. The ends are not detachable modules and should not be separated from the cable.
Standard configurations normally ship within one to three working days, while production quantities are confirmed with the order. Delivery can be arranged by courier, air freight or sea freight, and goods may instead be handed to an appointed forwarder or shipped on the customer’s courier account.
800G TransceiversOSFP and QSFP-DD modules for AI data center networks
400G QSFP-DDSR8, DR4, FR4 and LR4 modules and cables
100G QSFP28SR4, CWDM4, LR4 and ER4 transceivers
DAC CablesDirect attach copper cables from 10G up to 800G
AOC CablesActive optical cables for rack-to-rack links
MTP/MPO Trunk Cables8F to 144F multi fiber trunk and harness cables
Fiber Patch CablesOS2, OM3, OM4, OM5 jumpers with LC, SC, FC, ST connectors
Armored Patch CablesStainless steel tube protected fiber patch cords
UAE office: Abu Dhabi,Al khaleej Al Arabi
Factory add: ZYT industrial area, Shiyan, Baoan district, Shenzhen, China 518000