Extreme Networks 25GB-4-C02-QSFP28 Compatible 100G QSFP28 4 x 25G NRZ to 4 x 25G SFP28 NRZ Passive Copper Breakout Cable, 2m (7ft)

Extreme Networks 25GB-4-C02-QSFP28 Compatible 100G QSFP28 4 x 25G NRZ to 4 x 25G SFP28 NRZ Passive Copper Breakout Cable, 2m (7ft)

The product on this page is the 2m (7ft) version of Extreme Networks 25GB-4-C02-QSFP28, built for 100G operation with QSFP28 to SFP28. Its complete DAC construction simplifies the physical link, and the sections below cover the exact specification, rack-integration considerations and factory verification for this individual order code.

OEM Part Number: 25GB-4-C02-QSFP28HT Part Number: 25GB-4-C02-QSFP28

Product Highlights

  • Compatible alternative to Extreme Networks 25GB-4-C02-QSFP28
  • 100G connectivity at 100Gbps
  • Interface configuration: QSFP28 to SFP28
  • Fixed length and part number: 2m (7ft), 25GB-4-C02-QSFP28
  • Cable construction: Passive Twinax
  • Conductor specification: 30AWG
  • Maximum power consumption: ≤0.125W
  • Minimum bend radius: 60mm

Specifications

HT Part Number25GB-4-C02-QSFP28
Extreme Networks Compatible25GB-4-C02-QSFP28
ManufacturerHT
Form FactorQSFP28 to SFP28
Max Data Rate100Gbps
Cable TypePassive Twinax
Cable Length2m (7ft)
Wire AWG30AWG
Minimum Bend Radius60mm
Power Consumption≤0.125W
Power Supply3.3V
MTBF=50 Million Hours
Jacket MaterialPVC (OFNR)
Commercial Temperature Range0 to 70°C (32 to 158°F)
Modulation FormatQSFP28-4x 25G-NRZ SFP28-1x 25G-NRZ
MediaCopper
Application100G to 4x 25G Ethernet, Data Centers
ProtocolsIEEE 802.3, QSFP28 MSA, SFF-8665

Signal and Lane Configuration

The listed modulation format is QSFP28-4x 25G-NRZ SFP28-1x 25G-NRZ. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.

Position Within the Length Range

25GB-4-C02-QSFP28 occupies the middle of this family between 10421 at 1m (3ft) and 10423 at 3m (10ft). It adds 1m over the shorter option for extra routing clearance, while the next longer version adds another 1m. Measure the managed path and choose this version when its reach is sufficient without creating the slack associated with the longer assembly.

Data-Center Design and Airflow

Select the assembly by both reach and rack layout. A direct connection removes separate module-and-patch-cord interfaces, but it still needs a bend-safe pathway and clear connector access. Keep cable bundles from blocking front-panel airflow, account for the listed interface power where applicable and choose a length that supports maintenance without leaving an unmanaged coil. For this assembly, the listed conductor specification is 30AWG; the minimum bend radius is 60mm; the stated power consumption is ≤0.125W; the jacket material is PVC (OFNR).

Power and Thermal Planning

The rated power consumption is ≤0.125W. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.

Cable Construction and Routing

This assembly uses 30AWG conductors, PVC (OFNR) jacket, minimum bend radius 60mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.

Network and Protocol Considerations

The intended application is 100G to 4x 25G Ethernet, Data Centers. Listed interface and protocol references include IEEE 802.3, QSFP28 MSA, SFF-8665. Confirm that the host firmware and port configuration support the same operating mode.

Breakout Port Mapping

The QSFP28 to SFP28 configuration divides the high-speed interface into multiple lower-speed connections. Verify the upstream lane assignment, downstream port speeds and breakout setting on the host before connecting the assembly. Each branch must attach to the correct remote interface.

Passive Copper Operation

A passive DAC has no separate optical conversion stage. Its low-power, low-latency operation is useful for short equipment links, but the assembly must remain within the length and signaling mode accepted by both hosts.

Length Selection and Installation Planning

25GB-4-C02-QSFP28 provides 2m (7ft) for connections between separated rack units or nearby equipment positions. Plan the route around cable managers and power cords, keeping the assembly free from connector strain while avoiding a large obstruction in the airflow path.

Quality Assurance and Packaging

Each cable receives connector inspection and a functional link check before it is coiled with bend-safe slack and packed. Protective materials shield the connector housings during transport. Rack or project labels are available to keep length, part number and installation destination aligned. Standard protective packing is used by default, with project documentation arranged when requested.

Ordering Information

Provide the OEM reference, HT part number, fixed length and quantity, together with the intended host interfaces. Rack-based quantities and packaging instructions can be included for larger deployments. Other lengths are separate products and should be entered on their own order lines. This page’s fixed configuration is 2m (7ft); another length must be quoted under its corresponding part number.

Extreme Networks Compatibility and Factory Testing

Compatibility confirmation combines host identification with actual link establishment and diagnostic checks. The assembly is prepared for the stated OEM reference rather than selected only by connector shape. For a new data-center deployment, the equipment model, port mode and software release provide the most useful basis for a pre-order review. Where supported by the host, link stability and diagnostic indications are reviewed together with the established link.

Frequently Asked Questions

Is this an original Extreme Networks cable?

No. It is an HT-manufactured compatible alternative for equipment that specifies Extreme Networks 25GB-4-C02-QSFP28.

What details assist a compatibility review?

Provide the equipment manufacturer, model, port type, hardware revision and software release, together with the OEM reference, required length and quantity.

How should an unused assembly be stored?

Protect both connector ends, keep the cable in a loose bend-safe coil and retain its part-number label so the length and compatibility identity remain traceable.

Can different brands be connected with the same assembly?

Only where both hosts explicitly support the complete interface and compatibility arrangement. Document each end and select the appropriate brand-specific product when required.

Shipping and Lead Time

Standard configurations normally ship within one to three working days, while production quantities are confirmed with the order. Worldwide courier services are available, with air or sea freight for consolidated shipments; freight-collect delivery and coordination with a customer’s logistics provider can be arranged.


Featured Products


UAE Fiber Optics

UAE office: Abu Dhabi,Al khaleej Al Arabi
Factory add: ZYT industrial area, Shiyan, Baoan district, Shenzhen, China 518000

Popular Products

  • Fiber Optic Patch Cord
  • Fiber Optic Pigtail
  • Fiber Optic Attenuator
  • Fiber Optic Patch Panel
  • Fiber Optic Adapter