For data-center links that specify Brocade 40G-QSFP-C-0201, this 2m (7ft) DAC assembly delivers 40G connectivity through QSFP+ to QSFP+. It removes separate module-and-patch-cord interfaces while retaining clear mechanical, power and compatibility details for high-density design and installation planning.
OEM Part Number: 40G-QSFP-C-0201HT Part Number: 40G-QSFP-C-0201
| HT Part Number | 40G-QSFP-C-0201 |
|---|---|
| Brocade Compatible | 40G-QSFP-C-0201 |
| Manufacturer | HT |
| Connector Type | QSFP+ to QSFP+ |
| Max Data Rate | 40Gbps |
| Minimum Bend Radius | 35mm |
| Wire AWG | 30AWG |
| Cable Length | 2m (6.56ft) |
| Jacket Material | PVC (OFNR) |
| Temperature | 0 to 70°C (32 to 158°F) |
| Protocols | SFF-8436, QSFP+ MSA and IEEE 802.3ba |
This assembly uses 30AWG conductors, PVC (OFNR) jacket, minimum bend radius 35mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.
Select the assembly by both reach and rack layout. A direct connection removes separate module-and-patch-cord interfaces, but it still needs a bend-safe pathway and clear connector access. Keep cable bundles from blocking front-panel airflow, account for the listed interface power where applicable and choose a length that supports maintenance without leaving an unmanaged coil. For this assembly, the listed conductor specification is 30AWG; the minimum bend radius is 35mm; the jacket material is PVC (OFNR).
The intended application is determined by the host interface and protocol support. Listed interface and protocol references include SFF-8436, QSFP+ MSA and IEEE 802.3ba. Confirm that the host firmware and port configuration support the same operating mode.
A passive DAC has no separate optical conversion stage. Its low-power, low-latency operation is useful for short equipment links, but the assembly must remain within the length and signaling mode accepted by both hosts.
40G-QSFP-C-0201 provides 2m (7ft) for connections between separated rack units or nearby equipment positions. Plan the route around cable managers and power cords, keeping the assembly free from connector strain while avoiding a large obstruction in the airflow path.
40G-QSFP-C-0201 occupies the middle of this family between 40G-QSFP-C-01501 at 1.5m (5ft) and 40G-QSFP-C-0301 at 3m (10ft). It adds 0.5m over the shorter option for extra routing clearance, while the next longer version adds another 1m. Measure the managed path and choose this version when its reach is sufficient without creating the slack associated with the longer assembly.
Each cable receives connector inspection and a functional link check before it is coiled with bend-safe slack and packed. Protective materials shield the connector housings during transport. Rack or project labels are available to keep length, part number and installation destination aligned. Neutral packaging and customer-specific packing documentation are available on request.
Provide the OEM reference, HT part number, fixed length and quantity, together with the intended host interfaces. Rack-based quantities and packaging instructions can be included for larger deployments. Other lengths are separate products and should be entered on their own order lines. This page’s fixed configuration is 2m (7ft); another length must be quoted under its corresponding part number.
Compatibility confirmation combines host identification with actual link establishment and diagnostic checks. The assembly is prepared for the stated OEM reference rather than selected only by connector shape. For a new data-center deployment, the equipment model, port mode and software release provide the most useful basis for a pre-order review. The check includes link stability and diagnostic indications, followed by a final inspection of both ends.
No. It is an HT-manufactured compatible alternative for equipment that specifies Brocade 40G-QSFP-C-0201.
Not necessarily. Both hosts must support the stated rate, identification, lane mapping and any required breakout configuration; mechanical compatibility alone is insufficient.
Provide the equipment manufacturer, model, port type, hardware revision and software release, together with the OEM reference, required length and quantity.
Protect both connector ends, keep the cable in a loose bend-safe coil and retain its part-number label so the length and compatibility identity remain traceable.
Available stock is generally dispatched within one to three working days after order confirmation, with production lead times advised for larger quantities. Delivery can be arranged by courier, air freight or sea freight, and goods may instead be handed to an appointed forwarder or shipped on the customer’s courier account.
800G TransceiversOSFP and QSFP-DD modules for AI data center networks
400G QSFP-DDSR8, DR4, FR4 and LR4 modules and cables
100G QSFP28SR4, CWDM4, LR4 and ER4 transceivers
DAC CablesDirect attach copper cables from 10G up to 800G
AOC CablesActive optical cables for rack-to-rack links
MTP/MPO Trunk Cables8F to 144F multi fiber trunk and harness cables
Fiber Patch CablesOS2, OM3, OM4, OM5 jumpers with LC, SC, FC, ST connectors
Armored Patch CablesStainless steel tube protected fiber patch cords
UAE office: Abu Dhabi,Al khaleej Al Arabi
Factory add: ZYT industrial area, Shiyan, Baoan district, Shenzhen, China 518000