800G OSFP (IHS/Finned Top) to 2x 400G OSFP (RHS/Flat Top)-800G-ACC-1M3FT 800G OSFP 8 x 100G PAM4 IHS/Finned Top to 2 x 400G OSFP 4 x 100G PAM4 RHS/Flat Top Active Copper Breakout Cable, 1m (3ft)

800G OSFP (IHS/Finned Top) to 2x 400G OSFP (RHS/Flat Top)-800G-ACC-1M3FT 800G OSFP 8 x 100G PAM4 IHS/Finned Top to 2 x 400G OSFP 4 x 100G PAM4 RHS/Flat Top Active Copper Breakout Cable, 1m (3ft)

This 800G OSFP (IHS/Finned Top) to 2x 400G OSFP (RHS/Flat Top)-800G-ACC-1M3FT compatible ACC cable provides a 800G direct connection for Generic equipment in a fixed 1m (3ft) configuration. The 800G OSFP (IHS/Finned Top) to 2x 400G OSFP (RHS/Flat Top) assembly integrates both ends and the cable, giving data-center designers one defined product to evaluate for reach, rack layout, airflow and host compatibility.

OEM Part Number: 800G OSFP (IHS/Finned Top) to 2x 400G OSFP (RHS/Flat Top)-800G-ACC-1M3FTHT Part Number: 800G OSFP (IHS/Finned Top) to 2x 400G OSFP (RHS/Flat Top)-800G-ACC-1M3FT

Product Highlights

  • HT-manufactured ACC assembly in 1m (3ft)
  • 800G connectivity at 800Gbps
  • Interface configuration: 800G OSFP (IHS/Finned Top) to 2x 400G OSFP (RHS/Flat Top)
  • Fixed length and part number: 1m (3ft), 800G OSFP (IHS/Finned Top) to 2x 400G OSFP (RHS/Flat Top)-800G-ACC-1M3FT
  • Cable construction: Active Breakout DAC (ACC)
  • Conductor specification: 30AWG
  • Maximum power consumption: 1.5W (800G End)/0.6W (400G Per End)
  • Minimum bend radius: 32.5mm

Specifications

HT Part Number800G OSFP (IHS/Finned Top) to 2x 400G OSFP (RHS/Flat Top)-800G-ACC-1M3FT
ManufacturerHT
Form Factor800G OSFP (IHS/Finned Top) to 2x 400G OSFP (RHS/Flat Top)
Max. Data Rate800Gbps
MediaCopper
Cable TypeActive Breakout DAC (ACC)
Cable Length1m (3ft)
Jacket MaterialPET
Minimum Bend Radius32.5mm
Wire AWG30AWG
Max. Power Consumption1.5W (800G End)/0.6W (400G Per End)
Modulation Format8x 100G-PAM4 to Dual 4x 100G-PMA4
Commercial Temperature Range0 to 70°C (32 to 158°F)
Application800G/400G Ethernet
ProtocolsOSFP MSA, CMIS 5.0, IEEE 802.3 ck

Signal and Lane Configuration

The listed modulation format is 8x 100G-PAM4 to Dual 4x 100G-PMA4. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.

Length Selection and Installation Planning

At 1m (3ft), 800G OSFP (IHS/Finned Top) to 2x 400G OSFP (RHS/Flat Top)-800G-ACC-1M3FT is a practical choice for direct connections within one rack. Route the cable along the intended management path rather than pulling it diagonally across adjacent connectors, and leave enough clearance for insertion, removal and front-panel airflow.

Position Within the Length Range

800G OSFP (IHS/Finned Top) to 2x 400G OSFP (RHS/Flat Top)-800G-ACC-1M3FT is the shortest of 5 verified length options in this family. It is the preferred choice when the port positions are close and cable slack must be kept to a minimum. The next option is 800G OSFP (IHS/Finned Top) to 2x 400G OSFP (RHS/Flat Top)-800G-ACC-2M7FT at 2m (7ft), adding 1m for a less direct routing path; selecting it unnecessarily would leave more cable to dress.

Data-Center Design and Airflow

Select the assembly by both reach and rack layout. A direct connection removes separate module-and-patch-cord interfaces, but it still needs a bend-safe pathway and clear connector access. Keep cable bundles from blocking front-panel airflow, account for the listed interface power where applicable and choose a length that supports maintenance without leaving an unmanaged coil. For this assembly, the listed conductor specification is 30AWG; the minimum bend radius is 32.5mm; the stated power consumption is 1.5W (800G End)/0.6W (400G Per End); the jacket material is PET.

Power and Thermal Planning

The rated power consumption is 1.5W (800G End)/0.6W (400G Per End). Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.

Cable Construction and Routing

This assembly uses 30AWG conductors, PET jacket, minimum bend radius 32.5mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.

Network and Protocol Considerations

The intended application is 800G/400G Ethernet. Listed interface and protocol references include OSFP MSA, CMIS 5.0, IEEE 802.3 ck. Confirm that the host firmware and port configuration support the same operating mode.

Breakout Port Mapping

The 800G OSFP (IHS/Finned Top) to 2x 400G OSFP (RHS/Flat Top) configuration divides the high-speed interface into multiple lower-speed connections. Verify the upstream lane assignment, downstream port speeds and breakout setting on the host before connecting the assembly. Each branch must attach to the correct remote interface.

Quality Assurance and Packaging

Each cable receives connector inspection and a functional link check before it is coiled with bend-safe slack and packed. Protective materials shield the connector housings during transport. Rack or project labels are available to keep length, part number and installation destination aligned. Volume orders can include customer references on the labels and carton list.

Ordering Information

Provide the OEM reference, HT part number, fixed length and quantity, together with the intended host interfaces. Rack-based quantities and packaging instructions can be included for larger deployments. Other lengths are separate products and should be entered on their own order lines. This page’s fixed configuration is 1m (3ft); another length must be quoted under its corresponding part number.

Generic Compatibility and Factory Testing

Compatibility confirmation combines host identification with actual link establishment and diagnostic checks. The assembly is prepared for the stated OEM reference rather than selected only by connector shape. For a new data-center deployment, the equipment model, port mode and software release provide the most useful basis for a pre-order review. The check includes link stability and diagnostic indications, followed by a final inspection of both ends.

Frequently Asked Questions

Is this an original equipment manufacturer cable?

No. It is manufactured by HT under our own manufacturer identity.

How should an unused assembly be stored?

Protect both connector ends, keep the cable in a loose bend-safe coil and retain its part-number label so the length and compatibility identity remain traceable.

Can different brands be connected with the same assembly?

Only where both hosts explicitly support the complete interface and compatibility arrangement. Document each end and select the appropriate brand-specific product when required.

Does this order code cover multiple lengths?

No. 800G OSFP (IHS/Finned Top) to 2x 400G OSFP (RHS/Flat Top)-800G-ACC-1M3FT refers here to 1m (3ft). Every other verified length has a separate part number and page in the length list.

Shipping and Lead Time

Standard configurations normally ship within one to three working days, while production quantities are confirmed with the order. Worldwide courier services are available, with air or sea freight for consolidated shipments; freight-collect delivery and coordination with a customer’s logistics provider can be arranged.


Featured Products


UAE Fiber Optics

UAE office: Abu Dhabi,Al khaleej Al Arabi
Factory add: ZYT industrial area, Shiyan, Baoan district, Shenzhen, China 518000

Popular Products

  • Fiber Optic Patch Cord
  • Fiber Optic Pigtail
  • Fiber Optic Attenuator
  • Fiber Optic Patch Panel
  • Fiber Optic Adapter

Products Datasheet

PDF catalogues of our products to download or for general inquiry, please send an email to sales@huihongfiber.com for details.

Customer Support

For customer support, please leave email to sales@huihongfiber.com, we shall reply to you as soon as possible.