Custom LC/SC Duplex FTTA Outdoor Patch Cable, OS2, 7.0mm LSZH
Custom LC/SC Duplex FTTA Outdoor Patch Cable, OS2, 7.0mm LSZH

For UAE project teams, the key is to match this exact configuration to the port schedule, optical budget and delivery documentation. The custom duplex FTTA program builds the standard outdoor base station jumper to the precise setup of the site: LC or SC connectors in any mix, the measured path length from a few meters to full tower runs, and armored breakout lengths matched to the hardware at every end. This cable platform is unchanged: two OS2 9/125µm single-mode fibers of Corning G.657.A1 glass in a 7.0mm LSZH outdoor jacket, with helical steel armored branches protecting the tails and a potted, strain-relieved breakout point.

Product Highlights

  • Duplex OS2 9/125µm single mode, connector mix to order
  • LC, SC and mixed LC/SC combinations on one platform
  • Corning G.657.A1 bend-insensitive fiber, 20/10D bend radius
  • Armored breakout length selectable: 0.03/0.34/0.2m
  • 7.0mm LSZH UV-stabilized outdoor jacket
  • Any project length manufactured to order

Specifications

Connector TypeLC/SC, mix to order
Polish TypeUPC
Fiber ModeOS2 9/125µm
Wavelength1310/1550nm
Fiber CountDuplex / 2 Fibers
Fiber GradeCorning G.657.A1
Min. Bend Radius (Fiber Cable)20/10D (Dynamic/Static)
Attenuation at 1310nm≤0.36dB/km
Attenuation at 1550nm≤0.22dB/km
Cable JacketLow Smoke Zero Halogen (LSZH)
Cable Diameter (Outer/Inner)7.0/2.0mm
Armored Breakout Length (End A/B)0.03/0.34/0.2m, selectable
Tensile Strength200/400N (Long/Short Term)
Crush Resistance1100/2200N (Long/Short Term)
Insertion Loss≤0.3dB
Return Loss≥50dB
Operating Temperature-20 to 70°C (-4 to 158°F)
Storage Temperature-40 to 80°C (-40 to 176°F)

Configured around the site, not the catalog

Base station sites differ in each dimension: tower height, shelter location, enclosure type and hardware generation. A custom FTTA jumper takes those dimensions as input. This connector mix follows the actual ports on the baseband and radio sides, the length follows the measured path with working slack, and the armored breakout at every end follows the location where this trunk separates into legs. The result installs without adaptors, without a service loop of surplus cable, and without field termination.

Selecting the armored breakout length

The breakout is the point where the 7.0mm trunk divides into two protected legs. A short 0.03m breakout suits a compact enclosure where the two connectors sit side by side; the standard 0.34m armored branch reaches separated ports inside a radio shroud or distribution box; a 0.2m intermediate choice covers layouts in between. Selecting the right breakout keeps each centimeter of exposed fiber inside the helical steel tube, which is where crush and rodent damage actually happen.

The same outdoor rating as the standard family

Customization changes the setup, not the engineering. This cable retains the 200/400N long and short-term tensile rating for pulling and vertical hanging, the 1100/2200N crush resistance, and the -20 to 70 degree Celsius operating range. G.657.A1 glass keeps the 10D static bend tolerance that congested enclosures demand, and remains compatible with existing G.652.D feeder plant.

Documentation and repeatability for rollouts

For multi-site deployments, the setup is recorded once and repeated exactly: connector mix, length, breakout, identification. Crews at site fifty install the identical cord that was validated at site one, which keeps commissioning time predictable and spares planning simple. The identification scheme may observe the customer document, with leg identification at the two ends printed to match the site record.

Length options and customization

State the measured path length with the inquiry, including the tray route and working slack at the two ends; the factory builds to that figure and confirms the manufacturable specification prior to production.

Quality control and testing

Each custom cord is terminated with precision zirconia ferrule connectors and optically tested as an entire unit: insertion loss is verified against the 0.3dB ceiling and return loss against the 50dB minimum on every leg. End-face geometry is inspected on each connector, and the delivered cord is ready to plug into service without on-site rework.

Ordering and Factory Support

Send the necessary connector mix, path length and breakout preference with the inquiry. The factory confirms the manufacturable specification prior to production and keeps the setup on record for repeat orders across the rollout. Our UAE project support can review the requirement with Shenzhen production before a formal quotation is issued.

 

Fiber Optic UAE supplies Custom LC/SC Duplex FTTA Outdoor Patch Cable, OS2, 7.0mm LSZH to data centers, ISPs and enterprises in Dubai, Abu Dhabi, Sharjah and across the Gulf region, with project support from our UAE office and production coordination from our Shenzhen factory.


UAE Fiber Optics

UAE office: Abu Dhabi,Al khaleej Al Arabi
Factory add: ZYT industrial area, Shiyan, Baoan district, Shenzhen, China 518000

Popular Products

  • Fiber Optic Patch Cord
  • Fiber Optic Pigtail
  • Fiber Optic Attenuator
  • Fiber Optic Patch Panel
  • Fiber Optic Adapter

Products Datasheet

PDF catalogues of our products to download or for general inquiry, please send an email to sales@huihongfiber.com for details.

Customer Support

For customer support, please leave email to sales@huihongfiber.com, we shall reply to you as soon as possible.