Hardened SC APC to Hardened SC APC Fiber Drop Cable, OS2, IP68, Custom Length
Hardened SC APC to Hardened SC APC Fiber Drop Cable, OS2, IP68, Custom Length

For UAE project teams, the key is to match this exact configuration to the port schedule, optical budget and delivery documentation. This fiber drop cable carries a sealed optical interface at the two ends: hardened SC APC connectors, every IP68 rated, mate directly with the outdoor terminal ports at the two sides of the connection. It serves the spans where neither end is indoors: terminal to terminal, closure to pedestal, pole to facade box. This cable is the round 5.0mm outdoor build with one G.657.A2 bend-insensitive OS2 fiber, rated at 1200N tensile load and 1200N crush resistance, factory terminated and manufactured to the ordered length.

Product Highlights

  • Hardened SC APC (IP68) at both ends
  • Sealed tool-less mating with outdoor terminal ports
  • Round 5.0mm construction, 1200N tensile and crush rating
  • G.657.A2 bend-insensitive fiber, 20/10D cable bend radius
  • Insertion loss ≤0.3dB, return loss ≥60dB
  • Manufactured to the ordered route length

Specifications

Connector AHardened SC APC (IP68)
Connector BHardened SC APC (IP68)
Fiber ModeOS2 9/125µm
Wavelength1310/1550nm
Fiber Count1 Fiber
Fiber GradeG.657.A2
Min. Bend Radius (Optical Fiber)7.5mm
Min. Bend Radius (Fiber Cable)20/10D (Dynamic/Static)
Cable Outside Diameter (OD)5.0mm
Cable JacketLow Smoke Zero Halogen (LSZH)
Tensile Load1200N (Short Term)
Crush Resistance1200N/100mm (Short Term)
Insertion Loss≤0.3dB
Return Loss≥60dB
Attenuation at 1310nm≤0.36dB/km
Attenuation at 1550nm≤0.22dB/km
Operating Temperature-20 to 70°C (-4 to 158°F)
Storage Temperature-10 to 50°C (14 to 122°F)

Sealed at both ends for outdoor spans

Some drop routes never come indoors: a distribution terminal on the pole feeding a facade box across the street, a closure feeding a pedestal in a garden plot, a handhole connection between two sealed enclosures. On those spans the two connectors live outdoors, and the two need the sealed interface. Because the hardened-to-hardened drop cable offers exactly that: every end threads onto a matching terminal port and closes to IP68, the full link is environmentally sealed without a single field splice or enclosure seam.

The 1200N round construction

Spanning between structures asks more of a cable than a wall entry does. The round 5.0mm build carries its strength members around the core, rated at 1200N short-term tensile load and 1200N crush resistance per 100mm, roughly three times the rating of the flat drop build. This cable tolerates the tension of an aerial sag, the incidental pull while installing through conduit, and the crushing loads of duct sharing and ground work. The 20/10D cable bend radius keeps the glass safe at pole hardware and enclosure entries.

G.657.A2 glass in sealed hardware

Sealed terminals and pedestals are compact inside, and the fiber within them bends sharply around splice trays and port fields. G.657.A2 bend-insensitive glass tolerates a 7.5mm fiber bend radius, so the pigtail section inside the hardware may be dressed tightly without adding loss. The glass is fully compatible with the G.652.D feeder plant upstream, keeping the optical budget of the access network unchanged.

Repeatability for network builds

Terminal-to-terminal links repeat across a network by the hundreds. Specifying one cable build, one connector pair and a length plan per span type lets the factory build each connection identically, with the identical optical test record on every. Crews install the identical unit at each location, spares reduce to a handful of length variants, and the documentation for the whole rollout follows one template.

Length options and customization

Each drop cable in this series is manufactured to the length stated with the order rather than picked from fixed stock sizes, because last-mile routes differ from a few meters to well over a hundred. This cable is manufactured to the length stated with the order; measure the span including the sag allowance on aerial routes and the dressing slack inside the two enclosures. Specifying the measured path length avoids the two the slack storage problem of an overlong cable and the strain risk of one that is too short.

Quality control and testing

Each assembly is terminated with precision zirconia ferrule hardened connectors and optically tested as an entire cable: insertion loss is verified against the 0.3dB ceiling and return loss against the 60dB minimum. The two connectors are checked for seal integrity as well as optical behavior, so the delivered connection may be threaded onto the terminal ports and put into service without on-site rework.

Ordering and Factory Support

Refer to the hardened-to-hardened drop cable series when ordering a quotation and state the span length, terminal types and unit count per length. For mixed builds with a standard SC APC end for the subscriber side, or other hardened connector styles, send the site need with the inquiry and the factory will verify the manufacturable specification prior to production. Our UAE project support can review the requirement with Shenzhen production before a formal quotation is issued.

 

Fiber Optic UAE supplies Hardened SC APC to Hardened SC APC Fiber Drop Cable, OS2, IP68, Custom Length to data centers, ISPs and enterprises in Dubai, Abu Dhabi, Sharjah and across the Gulf region, with project support from our UAE office and production coordination from our Shenzhen factory.


UAE Fiber Optics

UAE office: Abu Dhabi,Al khaleej Al Arabi
Factory add: ZYT industrial area, Shiyan, Baoan district, Shenzhen, China 518000

Popular Products

  • Fiber Optic Patch Cord
  • Fiber Optic Pigtail
  • Fiber Optic Attenuator
  • Fiber Optic Patch Panel
  • Fiber Optic Adapter

Products Datasheet

PDF catalogues of our products to download or for general inquiry, please send an email to sales@huihongfiber.com for details.

Customer Support

For customer support, please leave email to sales@huihongfiber.com, we shall reply to you as soon as possible.