LC/SC/FC/ST/LSH Single Mode Fixed Fiber Optic Attenuator, Female to Female, 3-15dB

LC/SC/FC/ST/LSH Single Mode Fixed Fiber Optic Attenuator, Female to Female, 3-15dB

For UAE project teams, the key is to match this exact configuration to the port schedule, optical budget and delivery documentation. LC/SC/FC/ST/LSH Single Mode Fixed Fiber Optic Attenuator inserts a precisely calibrated fixed loss into a fiber connection. The attenuating element is ion-doped fiber - the loss is spectrally flat and reflection-free, unlike air-gap or offset designs - so the connection sees exactly the rated attenuation at each operating wavelength. The female-to-female body works inline between two standard patch patch cords, adding attenuation without disturbing this connector plan of the plant.

Product Highlights

  • Available in a Variety of Connector Types
  • Standard Fixed Attenuation Values of 3/5/7/10/15dB
  • Applied for CWDM, DWDM, Test Equipment, CATV Systems, Point to Point Systems, etc.
  • Attenuating Material-ion Doped Fiber
  • 1260 to 1620nm Wavelength Singlemode Attenuators

Specifications

Connector GenderFixed Female to Female
Attenuation3/5/7/10/15dB
Operating Wavelength(nm)1260~1620(SM)
Operating Temperature Range-25 to 70°C (-13 to 158°F)
Storage Temperature Range-40 to 85°C (-40 to 185°F)
Application(1)Length(1)

Available Attenuation Values

This female-to-female attenuator is stocked in the standard inline values: 3dB, 5dB, 7dB, 10dB, 15dB. Each value is individually calibrated and marked on the housing.

3dB   5dB   7dB   10dB   15dB

Why links need attenuation at all

Optical links are engineered with a power budget: the transmitter launches, the fiber and connectors consume, and the receiver expects what remains inside a defined window. Short routes, dense wavelength plans and high-power transmitters may all deliver too much light, and an overloaded receiver distorts exactly like an overloaded amplifier - errors appear on a connection that tests perfectly on loss alone. A fixed attenuator brings the received power back inside the window, and the connection behaves as designed.

Ion-doped fiber as the attenuating element

The cleanest way to attenuate light is to absorb it inside the fiber itself. Ion-doped fiber attenuators do exactly that: a short section of doped glass absorbs a calibrated fraction of the optical power and converts it to negligible heat. Because the attenuation happens inside the core, the light that emerges keeps its mode profile and the device adds virtually no reflectance. The alternatives - air gaps, offsets and misaligned ferrules - all trade loss against reflections and modal noise, which is why precision attenuators abandoned them. For UAE procurement, record this requirement with the project documents so the supplied configuration can be checked on arrival.

Choosing the attenuation value

The right figure is the difference between what the connection delivers and what the receiver wants, plus a small margin. Measure or calculate the expected receive power first; then choose the nearest standard figure - 1, 2, 3, 5, 7, 10, 15, 20 or 25 dB - that lands the receiver inside its window. Too little attenuation leaves the receiver overloaded; too much eats the margin that aging and repairs will need later. When the need sits between standard figures, the custom platform covers the precise figure.

Fixed values versus a variable instrument

Fixed attenuators win on stability, size and price: once the necessary loss is known, a fixed device holds it permanently with no moving parts. Variable attenuators win when the loss itself is the question - receiver sensitivity testing, margin surveys, multi-wavelength leveling - where sweeping the figure is the whole point. Most plants need the two: fixed units existing in the links, and a variable instrument in the test kit.

Female-to-female inline attenuators

The female-to-female body sits between two standard patch patch cords like a coupler with a calibrated loss. That format suits test setups and temporary installations where the attenuator moves between links, and plants where this connector plan is fixed and the attenuation must be added inline. Either way, the attenuation figure, not the gender, is what the connection sees.

Return loss and the polish discipline

An attenuator sits in the middle of the connection, so its reflectance counts twice - once toward the transmitter and once toward the receiver. UPC versions hold return loss at 50 dB or better, and APC versions at 60 dB or better, which keeps reflected power far below anything a modern transmitter notices. The polish grade must be matched to the plant: an APC attenuator mated to a UPC connector through an adapter damages the two end faces and destroys the very return loss it was selected to protect.

Handling and cleaning attenuators

An attenuator is a connector with optics inside, and connector rules apply: keep the caps on until the moment of mating, clean each end face before insertion, and never mate a contaminated ferrule into the device - the dirt transfers to the attenuator end face and the next connector that touches it. Store spare units capped and bagged, and record which connection every existing unit serves so replacement orders match the original figure.

Selecting the right attenuator

Four decisions define the order: the attenuation figure must be matched to the connection calculation, this connector series must be matched to the port or the patch cords, the polish grade must be matched to the plant, and the body style - plug or inline - must suit the deployment. Fixed figures cover permanent installations; the variable instruments cover testing; the test cable covers transceiver qualification. Getting all four right at order time is what turns a small component into a dependable part of the connection.

Quality Control and Testing

Each attenuator is optically verified before packing: the attenuation figure is measured at the operating wavelengths and checked against its rated tolerance, return loss is verified to its polish grade, and this connector end faces are inspected for scratches and contamination. Units ship capped and bagged.

Ordering and Factory Support

Refer to this attenuator by attenuation figure, connector series, polish grade and body style when ordering a quotation. For figures or configurations outside the listed options - non-standard dB figures, mixed connector pairings or project packing - send the need with the inquiry and the factory will verify the manufacturable specification. Our UAE project support can review the requirement with Shenzhen production before a formal quotation is issued.

 

Fiber Optic UAE supplies LC/SC/FC/ST/LSH Single Mode Fixed Fiber Optic Attenuator, Female to Female, 3-15dB to data centers, ISPs and enterprises in Dubai, Abu Dhabi, Sharjah and across the Gulf region, with project support from our UAE office and production coordination from our Shenzhen factory.


UAE Fiber Optics

UAE office: Abu Dhabi,Al khaleej Al Arabi
Factory add: ZYT industrial area, Shiyan, Baoan district, Shenzhen, China 518000

Popular Products

  • Fiber Optic Patch Cord
  • Fiber Optic Pigtail
  • Fiber Optic Attenuator
  • Fiber Optic Patch Panel
  • Fiber Optic Adapter

Products Datasheet

PDF catalogues of our products to download or for general inquiry, please send an email to sales@huihongfiber.com for details.

Customer Support

For customer support, please leave email to sales@huihongfiber.com, we shall reply to you as soon as possible.