LC UPC to Unterminated Fiber Pigtail, 12 Fibers, Bunch, OS2 |
![]() For UAE project teams, the key is to match this exact configuration to the port schedule, optical budget and delivery documentation. This fiber pigtail terminates outside-plant or backbone cable into a connectorized panel: LC UPC to Unterminated Fiber Pigtail, OS2 glass, with a factory-polished LC UPC connector on one end and a prepared fiber strand on the other. Fusion-spliced onto the incoming cable, it turns a raw fiber path into a documented, testable port. Product Highlights
Specifications
From raw fiber route to documented portEach structured cabling plant ends the identical way: a cable arrives at a frame, and its fibers must become ports. The pigtail is the component that makes that conversion. Spliced into a tray and presented on a panel, every strand gains a connector with a known optical signature, a location in the documentation and a place in the test record. That conversion - cable to port - is where connection quality is won or lost. Mechanical splicing as the field fallbackWhere a fusion splicer is not offered, mechanical splices get the connection up: the strand cleaves, seats in the mechanical splice body and locks against the field fiber. The loss is higher than a fusion joint and the reflectance worse, so the practice is a fallback rather than a standard - but for urgent restoration work a pigtail that supports the two methods keeps the choice open. Keeping twelve-fiber splices organizedMulti-fiber splicing rewards method: entire one color fully - strip, clean, cleave, splice, sleeve - before starting the next, and dress every finished strand into the tray in sequence. The color-coded set makes the pairing unambiguous, and the tray stays readable for the next technician who opens it. A tray that reads unambiguously is a tray that gets re-entered without new faults. Color coding as a working disciplineTwelve fibers, twelve colors, one order: the TIA-598 sequence is the only thing standing between a tidy splice tray and a crossed plant. The strands in this set observe the standard sequence, so the splicer matches colors between cable and pigtail without guesswork. When the documentation follows the identical sequence, a fault on location seven months from now is found in minutes rather than traced strand by strand. Unjacketed and bunch constructions comparedThe unjacketed color-coded set presents twelve distinct 0.9mm strands for direct tray work - the lightest build and the easiest to dress. The bunch build gathers the twelve strands under a shared jacket that breaks out near this connector end, adding handling protection on the path between this panel and the tray. Select unjacketed where the strands stay inside a protected enclosure; select bunch where this assembly crosses open space between frames. Bend-insensitive glass in dense traysSplice trays and panel rear spaces punish fiber: tight routing, crowded dressing and the occasional hurried re-entry all bend strands beyond what legacy single-mode tolerated. The bend-insensitive grade used in this pigtail holds attenuation stable at bend radii that would fog conventional glass, which keeps the connection margin intact after the tenth tray opening, not just at commissioning. Sparing and kit planning for termination workPigtails belong in the termination kit in counted sets with spares: strands break, connectors get contaminated beyond recovery, and a missing spare converts a ten-minute task into a second visit. Plan one spare set per frame location, keep spare strands capped and bagged, and record which set went into which tray so replacement stock may be ordered to the identical specification. A splicing workflow that scalesProductive termination crews work to a fixed routine: mount the tray, dress this cable, splice the pigtails color by color, protect every joint, test every completed port, then close and label. With the routine fixed, a two-person crew terminates a full frame location in a predictable time, and the test record maps cleanly onto the documentation. The consistency additionally makes quality auditable - identical materials, identical sequence, identical pass criteria across each site. Selecting the right pigtail for the jobFive decisions define the order: this connector series must be matched to this panel, the polish must be matched to the plant, the fiber mode must be matched to this cable, the build must be matched to the path, and the count must be matched to the tray capacity. Getting all five right at order time is what turns a box of strands into a dependable termination. Where the need sits outside the standard configurations, the custom platforms cover the remaining combinations. Quality Control and TestingEach pigtail is optically tested before packing: insertion loss and return loss are verified on every terminated leg, and the ferrule end faces are inspected for scratches and contamination. The strands ship coiled, capped and bagged, with the test results offered on specify. Ordering and Factory SupportRefer to this pigtail by connector, polish, fiber mode, fiber count and build when ordering a quotation. For configurations outside the listed options - mixed connector families, jacket ratings, lengths or project packing - send the need with the inquiry and the factory will verify the manufacturable specification. Our UAE project support can review the requirement with Shenzhen production before a formal quotation is issued. |
|||||||||||||||||||||||||||||||||||||||||
Fiber Optic UAE supplies LC UPC to Unterminated Fiber Pigtail, 12 Fibers, Bunch, OS2 to data centers, ISPs and enterprises in Dubai, Abu Dhabi, Sharjah and across the Gulf region, with project support from our UAE office and production coordination from our Shenzhen factory.
UAE office: Abu Dhabi,Al khaleej Al Arabi
Factory add: ZYT industrial area, Shiyan, Baoan district, Shenzhen, China 518000