The product on this page is the 15m (49ft) version of NVIDIA/Mellanox MFA7A50-C015, built for 100G operation with QSFP28 to 4x SFP28. Its complete AOC construction simplifies the physical link, and the sections below cover the exact specification, rack-integration considerations and factory verification for this individual order code.
OEM Part Number: MFA7A50-C015HT Part Number: MFA7A50-C015
| HT Part Number | MFA7A50-C015 |
|---|---|
| NVIDIA/Mellanox Ethernet Compatible | MFA7A50-C015 |
| Manufacturer | HT |
| Form Factor | QSFP28 to 4x SFP28 |
| Max. Data Rate | 100Gbps |
| Cable Length | 15m (49ft) |
| Cable Type | Breakout AOC |
| Wavelength | 850nm |
| Minimum Bend Radius | 30mm |
| Transmitter Type | VCSEL |
| Receiver Type | PIN |
| Max. Power Consumption | 2.2W (QSFP28 End)0.8W (SFP28 Per End) |
| Modulation Format | QSFP28-4x 25G-NRZ SFP28-1x 25G-NRZ |
| CDR (Clock and Data Recovery) | TX & RX Built-in CDR |
| Jacket Material | OFNP |
| DDM/DOM | Supported |
| Commercial Temperature Range | 0 to 70°C (32 to 158°F) |
| Protocols | QSFP28 MSA, SFP28 MSA |
The listed modulation format is QSFP28-4x 25G-NRZ SFP28-1x 25G-NRZ. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.
This assembly uses OFNP jacket, minimum bend radius 30mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.
The intended application is determined by the host interface and protocol support. Listed interface and protocol references include QSFP28 MSA, SFP28 MSA. Confirm that the host firmware and port configuration support the same operating mode.
The QSFP28 to 4x SFP28 configuration divides the high-speed interface into multiple lower-speed connections. Verify the upstream lane assignment, downstream port speeds and breakout setting on the host before connecting the assembly. Each branch must attach to the correct remote interface.
The optical engines and fiber are permanently integrated into this AOC. There are no detachable optical modules to clean or exchange. Handle the complete assembly by its connector housings and cable, and keep both ends matched to the same interface specification.
Measure twice before deploying this 15m (49ft) cable: once along the planned route and again after accounting for service access. The objective is adequate reach without a concealed surplus. Support the integrated optical cable and both optical engines, preserve front-panel clearance and check that nearby power cords or sharp hardware cannot damage the jacket. Within this family, MFA7A50-C010 is shorter at 10m (33ft), while MFA7A50-C020 is the next longer choice at 20m (66ft); comparing those two boundaries helps avoid both tension and unnecessary slack.
MFA7A50-C015 occupies the middle of this family between MFA7A50-C010 at 10m (33ft) and MFA7A50-C020 at 20m (66ft). It adds 5m over the shorter option for extra routing clearance, while the next longer version adds another 5m. Measure the managed path and choose this version when its reach is sufficient without creating the slack associated with the longer assembly.
Select the assembly by both reach and rack layout. A direct connection removes separate module-and-patch-cord interfaces, but it still needs a bend-safe pathway and clear connector access. Keep cable bundles from blocking front-panel airflow, account for the listed interface power where applicable and choose a length that supports maintenance without leaving an unmanaged coil. For this assembly, the minimum bend radius is 30mm; the stated power consumption is 2.2W (QSFP28 End)0.8W (SFP28 Per End); the jacket material is OFNP.
The rated power consumption is 2.2W (QSFP28 End)0.8W (SFP28 Per End). Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.
Each cable receives connector inspection and a functional link check before it is coiled with bend-safe slack and packed. Protective materials shield the connector housings during transport. Rack or project labels are available to keep length, part number and installation destination aligned. Standard protective packing is used by default, with project documentation arranged when requested.
Provide the OEM reference, HT part number, fixed length and quantity, together with the intended host interfaces. Rack-based quantities and packaging instructions can be included for larger deployments. Other lengths are separate products and should be entered on their own order lines. Quantity and any labeling instructions should be attached specifically to MFA7A50-C015.
Compatibility confirmation combines host identification with actual link establishment and diagnostic checks. The assembly is prepared for the stated OEM reference rather than selected only by connector shape. For a new data-center deployment, the equipment model, port mode and software release provide the most useful basis for a pre-order review. Both connectors are examined before the operating test, which includes receive activity and diagnostic indications.
No. It is an HT-manufactured compatible alternative for equipment that specifies NVIDIA/Mellanox MFA7A50-C015.
Protect both connector ends, keep the cable in a loose bend-safe coil and retain its part-number label so the length and compatibility identity remain traceable.
Only where both hosts explicitly support the complete interface and compatibility arrangement. Document each end and select the appropriate brand-specific product when required.
No. MFA7A50-C015 refers here to 15m (49ft). Every other verified length has a separate part number and page in the length list.
Available stock is generally dispatched within one to three working days after order confirmation, with production lead times advised for larger quantities. Delivery can be arranged by courier, air freight or sea freight, and goods may instead be handed to an appointed forwarder or shipped on the customer’s courier account.
800G TransceiversOSFP and QSFP-DD modules for AI data center networks
400G QSFP-DDSR8, DR4, FR4 and LR4 modules and cables
100G QSFP28SR4, CWDM4, LR4 and ER4 transceivers
DAC CablesDirect attach copper cables from 10G up to 800G
AOC CablesActive optical cables for rack-to-rack links
MTP/MPO Trunk Cables8F to 144F multi fiber trunk and harness cables
Fiber Patch CablesOS2, OM3, OM4, OM5 jumpers with LC, SC, FC, ST connectors
Armored Patch CablesStainless steel tube protected fiber patch cords
UAE office: Abu Dhabi,Al khaleej Al Arabi
Factory add: ZYT industrial area, Shiyan, Baoan district, Shenzhen, China 518000