NVIDIA/Mellanox MFA7U10-H010-FLT Compatible 400G OSFP 8 x 50G PAM4 RHS/Flat Top to 2 x 200G QSFP56 4 x 50G PAM4 InfiniBand HDR Active Optical Breakout Cable, 10m (33ft)

NVIDIA/Mellanox MFA7U10-H010-FLT Compatible 400G OSFP 8 x 50G PAM4 RHS/Flat Top to 2 x 200G QSFP56 4 x 50G PAM4 InfiniBand HDR Active Optical Breakout Cable, 10m (33ft)

For data-center links that specify NVIDIA/Mellanox MFA7U10-H010-FLT, this 10m (33ft) AOC assembly delivers 400G connectivity through OSFP (RHS/Flat Top) to 2x QSFP56. It removes separate module-and-patch-cord interfaces while retaining clear mechanical, power and compatibility details for high-density design and installation planning.

OEM Part Number: MFA7U10-H010-FLTHT Part Number: MFA7U10-H010-FLT

Product Highlights

  • Compatible alternative to NVIDIA/Mellanox MFA7U10-H010-FLT
  • 400G connectivity at 400Gbps
  • Interface configuration: OSFP (RHS/Flat Top) to 2x QSFP56
  • Fixed length and part number: 10m (33ft), MFA7U10-H010-FLT
  • Cable construction: Breakout AOC
  • Maximum power consumption: 10W (OSFP End) 5.5W (QSFP56 Per End)
  • Minimum bend radius: 30mm
  • Operating temperature: 0 to 70°C (32 to 158°F)

Specifications

HT Part NumberMFA7U10-H010-FLT
NVIDIA/Mellanox InfiniBand CompatibleMFA7U10-H010-FLT
ManufacturerHT
Form FactorOSFP (RHS/Flat Top) to 2x QSFP56
Max. Data Rate400Gbps
Cable Length10m (33ft)
Cable TypeBreakout AOC
Wavelength850nm
Minimum Bend Radius30mm
Transmitter TypeVSCEL
Receiver TypePIN
Max. Power Consumption10W (OSFP End) 5.5W (QSFP56 Per End)
Jacket MaterialOFNP
CDR (Clock and Data Recovery)TX & RX Built-in CDR
Modulation Format8x 50G-PAM4 to Dual 4x 50G-PAM4
DDM/DOMSupported
Commercial Temperature Range0 to 70°C (32 to 158°F)
ProtocolsCMIS 4.0, SFF-8636,IEEE 802.3 bs-2*200GAUI-4, IEEE 802.3 bs-200GAUI-4, OSFP MSA, SFF-8679, SFF-8661

Signal and Lane Configuration

The listed modulation format is 8x 50G-PAM4 to Dual 4x 50G-PAM4. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.

Network and Protocol Considerations

The intended application is determined by the host interface and protocol support. Listed interface and protocol references include CMIS 4.0, SFF-8636,IEEE 802.3 bs-2*200GAUI-4, IEEE 802.3 bs-200GAUI-4, OSFP MSA, SFF-8679, SFF-8661. Confirm that the host firmware and port configuration support the same operating mode.

Breakout Port Mapping

The OSFP (RHS/Flat Top) to 2x QSFP56 configuration divides the high-speed interface into multiple lower-speed connections. Verify the upstream lane assignment, downstream port speeds and breakout setting on the host before connecting the assembly. Each branch must attach to the correct remote interface.

Integrated Optical Assembly

The optical engines and fiber are permanently integrated into this AOC. There are no detachable optical modules to clean or exchange. Handle the complete assembly by its connector housings and cable, and keep both ends matched to the same interface specification.

Length Selection and Installation Planning

The installation review for a 10m (33ft) link should include pathway length, support points, connector access and future maintenance. Route the integrated optical cable and both optical engines before attaching both ends, and avoid dragging it across connector panels. A final inspection should confirm that no latch, boot or jacket section carries unnecessary strain. Within this family, MFA7U10-H005-FLT is shorter at 5m (16ft), while MFA7U10-H015-FLT is the next longer choice at 15m (49ft); comparing those two boundaries helps avoid both tension and unnecessary slack.

Position Within the Length Range

MFA7U10-H010-FLT occupies the middle of this family between MFA7U10-H005-FLT at 5m (16ft) and MFA7U10-H015-FLT at 15m (49ft). It adds 5m over the shorter option for extra routing clearance, while the next longer version adds another 5m. Measure the managed path and choose this version when its reach is sufficient without creating the slack associated with the longer assembly.

Data-Center Design and Airflow

Select the assembly by both reach and rack layout. A direct connection removes separate module-and-patch-cord interfaces, but it still needs a bend-safe pathway and clear connector access. Keep cable bundles from blocking front-panel airflow, account for the listed interface power where applicable and choose a length that supports maintenance without leaving an unmanaged coil. For this assembly, the minimum bend radius is 30mm; the stated power consumption is 10W (OSFP End) 5.5W (QSFP56 Per End); the jacket material is OFNP.

Power and Thermal Planning

The rated power consumption is 10W (OSFP End) 5.5W (QSFP56 Per End). Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.

Cable Construction and Routing

This assembly uses OFNP jacket, minimum bend radius 30mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.

Quality Assurance and Packaging

Each cable receives connector inspection and a functional link check before it is coiled with bend-safe slack and packed. Protective materials shield the connector housings during transport. Rack or project labels are available to keep length, part number and installation destination aligned. Neutral packaging and customer-specific packing documentation are available on request.

Ordering Information

Provide the OEM reference, HT part number, fixed length and quantity, together with the intended host interfaces. Rack-based quantities and packaging instructions can be included for larger deployments. Other lengths are separate products and should be entered on their own order lines. Keep MFA7U10-H010-FLT associated with 10m (33ft) throughout the order and receiving record.

NVIDIA/Mellanox Compatibility and Factory Testing

Compatibility confirmation combines host identification with actual link establishment and diagnostic checks. The assembly is prepared for the stated OEM reference rather than selected only by connector shape. For a new data-center deployment, the equipment model, port mode and software release provide the most useful basis for a pre-order review. The check includes receive activity and diagnostic indications, followed by a final inspection of both ends.

Frequently Asked Questions

Is this an original NVIDIA/Mellanox cable?

No. It is an HT-manufactured compatible alternative for equipment that specifies NVIDIA/Mellanox MFA7U10-H010-FLT.

How should an unused assembly be stored?

Protect both connector ends, keep the cable in a loose bend-safe coil and retain its part-number label so the length and compatibility identity remain traceable.

Can different brands be connected with the same assembly?

Only where both hosts explicitly support the complete interface and compatibility arrangement. Document each end and select the appropriate brand-specific product when required.

Does this order code cover multiple lengths?

No. MFA7U10-H010-FLT refers here to 10m (33ft). Every other verified length has a separate part number and page in the length list.

Shipping and Lead Time

Standard configurations normally ship within one to three working days, while production quantities are confirmed with the order. International express, air cargo and sea freight can be selected according to destination and carton volume; customer courier accounts and nominated forwarders are also accepted.


Featured Products


UAE Fiber Optics

UAE office: Abu Dhabi,Al khaleej Al Arabi
Factory add: ZYT industrial area, Shiyan, Baoan district, Shenzhen, China 518000

Popular Products

  • Fiber Optic Patch Cord
  • Fiber Optic Pigtail
  • Fiber Optic Attenuator
  • Fiber Optic Patch Panel
  • Fiber Optic Adapter

Products Datasheet

PDF catalogues of our products to download or for general inquiry, please send an email to sales@huihongfiber.com for details.

Customer Support

For customer support, please leave email to sales@huihongfiber.com, we shall reply to you as soon as possible.