The product on this page is the 15m (49ft) version of NVIDIA/Mellanox MFA7U20-H015, built for 400G operation with OSFP (IHS/Finned Top) to 4x QSFP56. Its complete AOC construction simplifies the physical link, and the sections below cover the exact specification, rack-integration considerations and factory verification for this individual order code.
OEM Part Number: MFA7U20-H015HT Part Number: MFA7U20-H015
| HT Part Number | MFA7U20-H015 |
|---|---|
| NVIDIA/Mellanox InfiniBandCompatible | MFA7U20-H015 |
| Manufacturer | HT |
| Form Factor | OSFP (IHS/Finned Top) to 4x QSFP56 |
| Max. Data Rate | 400Gbps |
| Cable Length | 15m (49ft) |
| Cable Type | Breakout AOC |
| Wavelength | 850nm |
| Minimum Bend Radius | 30mm |
| Transmitter Type | VSCEL |
| Receiver Type | PIN |
| Max. Power Consumption | 10W (OSFP End) 5.5W (QSFP56 Per End) |
| Modulation Format | OSFP-8x 50G-PAM4QSFP56-2x 50G-PAM4 |
| CDR (Clock and Data Recovery) | TX & RX Built-in CDR |
| Jacket Material | OFNP |
| DDM/DOM | Supported |
| Commercial Temperature Range | 0 to 70°C (32 to 158°F) |
| Protocols | IEEE 802.3cd, CMIS 5.0, SFF-8661, SFF-8636 |
| Application | 400G to 4x 100G |
The listed modulation format is OSFP-8x 50G-PAM4QSFP56-2x 50G-PAM4. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.
The rated power consumption is 10W (OSFP End) 5.5W (QSFP56 Per End). Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.
This assembly uses OFNP jacket, minimum bend radius 30mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.
The intended application is 400G to 4x 100G. Listed interface and protocol references include IEEE 802.3cd, CMIS 5.0, SFF-8661, SFF-8636. Confirm that the host firmware and port configuration support the same operating mode.
The OSFP (IHS/Finned Top) to 4x QSFP56 configuration divides the high-speed interface into multiple lower-speed connections. Verify the upstream lane assignment, downstream port speeds and breakout setting on the host before connecting the assembly. Each branch must attach to the correct remote interface.
The optical engines and fiber are permanently integrated into this AOC. There are no detachable optical modules to clean or exchange. Handle the complete assembly by its connector housings and cable, and keep both ends matched to the same interface specification.
Measure twice before deploying this 15m (49ft) cable: once along the planned route and again after accounting for service access. The objective is adequate reach without a concealed surplus. Support the integrated optical cable and both optical engines, preserve front-panel clearance and check that nearby power cords or sharp hardware cannot damage the jacket. Within this family, MFA7U20-H010 is shorter at 10m (33ft), while MFA7U20-H020 is the next longer choice at 20m (66ft); comparing those two boundaries helps avoid both tension and unnecessary slack.
MFA7U20-H015 occupies the middle of this family between MFA7U20-H010 at 10m (33ft) and MFA7U20-H020 at 20m (66ft). It adds 5m over the shorter option for extra routing clearance, while the next longer version adds another 5m. Measure the managed path and choose this version when its reach is sufficient without creating the slack associated with the longer assembly.
Select the assembly by both reach and rack layout. A direct connection removes separate module-and-patch-cord interfaces, but it still needs a bend-safe pathway and clear connector access. Keep cable bundles from blocking front-panel airflow, account for the listed interface power where applicable and choose a length that supports maintenance without leaving an unmanaged coil. For this assembly, the minimum bend radius is 30mm; the stated power consumption is 10W (OSFP End) 5.5W (QSFP56 Per End); the jacket material is OFNP.
Each cable receives connector inspection and a functional link check before it is coiled with bend-safe slack and packed. Protective materials shield the connector housings during transport. Rack or project labels are available to keep length, part number and installation destination aligned. Volume orders can include customer references on the labels and carton list.
Provide the OEM reference, HT part number, fixed length and quantity, together with the intended host interfaces. Rack-based quantities and packaging instructions can be included for larger deployments. Other lengths are separate products and should be entered on their own order lines. This page’s fixed configuration is 15m (49ft); another length must be quoted under its corresponding part number.
Compatibility confirmation combines host identification with actual link establishment and diagnostic checks. The assembly is prepared for the stated OEM reference rather than selected only by connector shape. For a new data-center deployment, the equipment model, port mode and software release provide the most useful basis for a pre-order review. The check includes receive activity and diagnostic indications, followed by a final inspection of both ends.
No. It is an HT-manufactured compatible alternative for equipment that specifies NVIDIA/Mellanox MFA7U20-H015.
Provide the equipment manufacturer, model, port type, hardware revision and software release, together with the OEM reference, required length and quantity.
Protect both connector ends, keep the cable in a loose bend-safe coil and retain its part-number label so the length and compatibility identity remain traceable.
Only where both hosts explicitly support the complete interface and compatibility arrangement. Document each end and select the appropriate brand-specific product when required.
Standard configurations normally ship within one to three working days, while production quantities are confirmed with the order. International express, air cargo and sea freight can be selected according to destination and carton volume; customer courier accounts and nominated forwarders are also accepted.
800G TransceiversOSFP and QSFP-DD modules for AI data center networks
400G QSFP-DDSR8, DR4, FR4 and LR4 modules and cables
100G QSFP28SR4, CWDM4, LR4 and ER4 transceivers
DAC CablesDirect attach copper cables from 10G up to 800G
AOC CablesActive optical cables for rack-to-rack links
MTP/MPO Trunk Cables8F to 144F multi fiber trunk and harness cables
Fiber Patch CablesOS2, OM3, OM4, OM5 jumpers with LC, SC, FC, ST connectors
Armored Patch CablesStainless steel tube protected fiber patch cords
UAE office: Abu Dhabi,Al khaleej Al Arabi
Factory add: ZYT industrial area, Shiyan, Baoan district, Shenzhen, China 518000