Juniper Networks OSFP-800G-AOC-30M Compatible 800G OSFP 8 x 100G PAM4 IHS/Finned Top Active Optical Cable, 30m (98ft)

Juniper Networks OSFP-800G-AOC-30M Compatible 800G OSFP 8 x 100G PAM4 IHS/Finned Top Active Optical Cable, 30m (98ft)

For data-center links that specify Juniper Networks OSFP-800G-AOC-30M, this 30m (98ft) AOC assembly delivers 800G connectivity through OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top). It removes separate module-and-patch-cord interfaces while retaining clear mechanical, power and compatibility details for high-density design and installation planning.

OEM Part Number: OSFP-800G-AOC-30MHT Part Number: OSFP-800G-AOC-30M

Product Highlights

  • Compatible alternative to Juniper Networks OSFP-800G-AOC-30M
  • 800G connectivity at 800Gbps
  • Interface configuration: OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)
  • Fixed length and part number: 30m (98ft), OSFP-800G-AOC-30M
  • Cable construction: Active Optical Cable
  • Maximum power consumption: 14W Per End
  • Minimum bend radius: 30mm
  • Operating temperature: 0 to 70°C (32 to 158°F)

Specifications

HT Part NumberOSFP-800G-AOC-30M
Juniper Networks CompatibleOSFP-800G-AOC-30M
ManufacturerHT
Form FactorOSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)
Max. Data Rate800Gbps
Cable Length30m (98ft)
Cable TypeActive Optical Cable
Wavelength850nm
Minimum Bend Radius30mm
Transmitter TypeVCSEL
Receiver TypePIN
Max. Power Consumption14W Per End
Modulation Format8x 100G-PAM4
CDR (Clock and Data Recovery)TX & RX Built-in CDR
Jacket MaterialOFNP
DDM/DOMSupported
Commercial Temperature Range0 to 70°C (32 to 158°F)
ProtocolsOSFP MSA, CMIS Rev 4.0, SFF-8679, IEEE 802.3bs

Juniper Deployment Reference

Juniper platform documentation distinguishes straight QSFP28 DAC or AOC connections from DACBO and AOCBO breakout operation. On channelized systems, the host port must be configured for the required breakout mode. Match this HT compatible cable to the exact Juniper part number and the intended platform configuration.

Data-Center Design and Airflow

Select the assembly by both reach and rack layout. A direct connection removes separate module-and-patch-cord interfaces, but it still needs a bend-safe pathway and clear connector access. Keep cable bundles from blocking front-panel airflow, account for the listed interface power where applicable and choose a length that supports maintenance without leaving an unmanaged coil. For this assembly, the minimum bend radius is 30mm; the stated power consumption is 14W Per End; the jacket material is OFNP.

Signal and Lane Configuration

The listed modulation format is 8x 100G-PAM4. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.

Power and Thermal Planning

The rated power consumption is 14W Per End. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.

Cable Construction and Routing

This assembly uses OFNP jacket, minimum bend radius 30mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.

Network and Protocol Considerations

The intended application is determined by the host interface and protocol support. Listed interface and protocol references include OSFP MSA, CMIS Rev 4.0, SFF-8679, IEEE 802.3bs. Confirm that the host firmware and port configuration support the same operating mode.

Integrated Optical Assembly

The optical engines and fiber are permanently integrated into this AOC. There are no detachable optical modules to clean or exchange. Handle the complete assembly by its connector housings and cable, and keep both ends matched to the same interface specification.

Length Selection and Installation Planning

Choose OSFP-800G-AOC-30M when the measured managed path justifies 30m (98ft), not simply to leave a large spare coil. Additional reach can simplify adjacent-rack routing, yet unused cable still needs bend-safe storage and ventilation clearance. Keep identification visible so this extended version is not confused with shorter spares. Within this family, OSFP-800G-AOC-25M is shorter at 25m (82ft), while OSFP-800G-AOC-50M is the next longer choice at 50m (164ft); comparing those two boundaries helps avoid both tension and unnecessary slack.

Position Within the Length Range

OSFP-800G-AOC-30M occupies the middle of this family between OSFP-800G-AOC-25M at 25m (82ft) and OSFP-800G-AOC-50M at 50m (164ft). It adds 5m over the shorter option for extra routing clearance, while the next longer version adds another 20m. Measure the managed path and choose this version when its reach is sufficient without creating the slack associated with the longer assembly.

Quality Assurance and Packaging

Each cable receives connector inspection and a functional link check before it is coiled with bend-safe slack and packed. Protective materials shield the connector housings during transport. Rack or project labels are available to keep length, part number and installation destination aligned. Standard protective packing is used by default, with project documentation arranged when requested.

Ordering Information

Provide the OEM reference, HT part number, fixed length and quantity, together with the intended host interfaces. Rack-based quantities and packaging instructions can be included for larger deployments. Other lengths are separate products and should be entered on their own order lines. Keep OSFP-800G-AOC-30M associated with 30m (98ft) throughout the order and receiving record.

Juniper Networks Compatibility and Factory Testing

Compatibility confirmation combines host identification with actual link establishment and diagnostic checks. The assembly is prepared for the stated OEM reference rather than selected only by connector shape. For a new data-center deployment, the equipment model, port mode and software release provide the most useful basis for a pre-order review. Where supported by the host, receive activity and diagnostic indications are reviewed together with the established link.

Frequently Asked Questions

Is this an original Juniper Networks cable?

No. It is an HT-manufactured compatible alternative for equipment that specifies Juniper Networks OSFP-800G-AOC-30M.

What details assist a compatibility review?

Provide the equipment manufacturer, model, port type, hardware revision and software release, together with the OEM reference, required length and quantity.

How should an unused assembly be stored?

Protect both connector ends, keep the cable in a loose bend-safe coil and retain its part-number label so the length and compatibility identity remain traceable.

Can different brands be connected with the same assembly?

Only where both hosts explicitly support the complete interface and compatibility arrangement. Document each end and select the appropriate brand-specific product when required.

Shipping and Lead Time

Available stock is generally dispatched within one to three working days after order confirmation, with production lead times advised for larger quantities. Worldwide courier services are available, with air or sea freight for consolidated shipments; freight-collect delivery and coordination with a customer’s logistics provider can be arranged.


Featured Products


UAE Fiber Optics

UAE office: Abu Dhabi,Al khaleej Al Arabi
Factory add: ZYT industrial area, Shiyan, Baoan district, Shenzhen, China 518000

Popular Products

  • Fiber Optic Patch Cord
  • Fiber Optic Pigtail
  • Fiber Optic Attenuator
  • Fiber Optic Patch Panel
  • Fiber Optic Adapter

Products Datasheet

PDF catalogues of our products to download or for general inquiry, please send an email to sales@huihongfiber.com for details.

Customer Support

For customer support, please leave email to sales@huihongfiber.com, we shall reply to you as soon as possible.