OSFP (IHS/Finned Top) to 2x OSFP (RHS/Flat Top)-800G-AEC-5M16FT 800G OSFP 8 x 100G PAM4 IHS/Finned Top to 2 x 400G OSFP 4 x 100G PAM4 RHS/Flat Top Active Electrical Copper Breakout Cable, 5m (16ft)

OSFP (IHS/Finned Top) to 2x OSFP (RHS/Flat Top)-800G-AEC-5M16FT 800G OSFP 8 x 100G PAM4 IHS/Finned Top to 2 x 400G OSFP 4 x 100G PAM4 RHS/Flat Top Active Electrical Copper Breakout Cable, 5m (16ft)

This OSFP (IHS/Finned Top) to 2x OSFP (RHS/Flat Top)-800G-AEC-5M16FT compatible AEC cable provides a 800G direct connection for Generic equipment in a fixed 5m (16ft) configuration. The OSFP (IHS/Finned Top) to 2x OSFP (RHS/Flat Top) assembly integrates both ends and the cable, giving data-center designers one defined product to evaluate for reach, rack layout, airflow and host compatibility.

OEM Part Number: OSFP (IHS/Finned Top) to 2x OSFP (RHS/Flat Top)-800G-AEC-5M16FTHT Part Number: OSFP (IHS/Finned Top) to 2x OSFP (RHS/Flat Top)-800G-AEC-5M16FT

Product Highlights

  • HT-manufactured AEC assembly in 5m (16ft)
  • 800G connectivity at 800Gbps
  • Interface configuration: OSFP (IHS/Finned Top) to 2x OSFP (RHS/Flat Top)
  • Fixed length and part number: 5m (16ft), OSFP (IHS/Finned Top) to 2x OSFP (RHS/Flat Top)-800G-AEC-5M16FT
  • Cable construction: Active Breakout DAC (AEC)
  • Conductor specification: 28AWG
  • Maximum power consumption: 12W (800G End)10W (400G Per End)
  • Minimum bend radius: 38mm

Specifications

HT Part NumberOSFP (IHS/Finned Top) to 2x OSFP (RHS/Flat Top)-800G-AEC-5M16FT
ManufacturerHT
Form FactorOSFP (IHS/Finned Top) to 2x OSFP (RHS/Flat Top)
Max. Data Rate800Gbps
MediaCopper
Cable TypeActive Breakout DAC (AEC)
Cable Length5m (16ft)
Jacket MaterialPET
Minimum Bend Radius38mm
Wire AWG28AWG
Max. Power Consumption12W (800G End)10W (400G Per End)
Modulation Format8x100G-PAM4 to Dual 4x100G-PAM4
Commercial Temperature Range0 to 70°C (32 to 158°F)
Application800G/400G Ethernet
ProtocolsOSFP MSA Rev5.1, IEEE 802.3ck, CMIS 5.0

Signal and Lane Configuration

The listed modulation format is 8x100G-PAM4 to Dual 4x100G-PAM4. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.

Power and Thermal Planning

The rated power consumption is 12W (800G End)10W (400G Per End). Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.

Cable Construction and Routing

This assembly uses 28AWG conductors, PET jacket, minimum bend radius 38mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.

Network and Protocol Considerations

The intended application is 800G/400G Ethernet. Listed interface and protocol references include OSFP MSA Rev5.1, IEEE 802.3ck, CMIS 5.0. Confirm that the host firmware and port configuration support the same operating mode.

Breakout Port Mapping

The OSFP (IHS/Finned Top) to 2x OSFP (RHS/Flat Top) configuration divides the high-speed interface into multiple lower-speed connections. Verify the upstream lane assignment, downstream port speeds and breakout setting on the host before connecting the assembly. Each branch must attach to the correct remote interface.

Length Selection and Installation Planning

The 5m (16ft) length gives OSFP (IHS/Finned Top) to 2x OSFP (RHS/Flat Top)-800G-AEC-5M16FT more freedom for adjacent-rack and row-end deployments. Longer copper runs need particular attention to routing weight and bend control; the AEC specification and host support must still match the intended link.

Position Within the Length Range

OSFP (IHS/Finned Top) to 2x OSFP (RHS/Flat Top)-800G-AEC-5M16FT is the longest of 5 verified length options in this family. Compared with OSFP (IHS/Finned Top) to 2x OSFP (RHS/Flat Top)-800G-AEC-4M13FT at 4m (13ft), it provides 1m of additional reach for a longer vertical drop, a wider rack or an adjacent-cabinet route. Confirm that the complete path requires this length, because unused slack still needs supported, bend-safe storage.

Data-Center Design and Airflow

Select the assembly by both reach and rack layout. A direct connection removes separate module-and-patch-cord interfaces, but it still needs a bend-safe pathway and clear connector access. Keep cable bundles from blocking front-panel airflow, account for the listed interface power where applicable and choose a length that supports maintenance without leaving an unmanaged coil. For this assembly, the listed conductor specification is 28AWG; the minimum bend radius is 38mm; the stated power consumption is 12W (800G End)10W (400G Per End); the jacket material is PET.

Quality Assurance and Packaging

Each cable receives connector inspection and a functional link check before it is coiled with bend-safe slack and packed. Protective materials shield the connector housings during transport. Rack or project labels are available to keep length, part number and installation destination aligned. Volume orders can include customer references on the labels and carton list.

Ordering Information

Provide the OEM reference, HT part number, fixed length and quantity, together with the intended host interfaces. Rack-based quantities and packaging instructions can be included for larger deployments. Other lengths are separate products and should be entered on their own order lines. This page’s fixed configuration is 5m (16ft); another length must be quoted under its corresponding part number.

Generic Compatibility and Factory Testing

Compatibility confirmation combines host identification with actual link establishment and diagnostic checks. The assembly is prepared for the stated OEM reference rather than selected only by connector shape. For a new data-center deployment, the equipment model, port mode and software release provide the most useful basis for a pre-order review. Where supported by the host, link stability and diagnostic indications are reviewed together with the established link.

Frequently Asked Questions

Is this an original equipment manufacturer cable?

No. It is manufactured by HT under our own manufacturer identity.

Are separate transceivers or patch leads required?

No. This is one complete direct-attach assembly. The ends are not detachable modules and should not be separated from the cable.

Can excess cable be folded into a compact bundle?

No. Use a supported, bend-safe service loop and observe the listed minimum bend radius. Do not crease the cable or tighten ties around the connector boots.

Will any matching connector operate at the same speed?

Not necessarily. Both hosts must support the stated rate, identification, lane mapping and any required breakout configuration; mechanical compatibility alone is insufficient.

Shipping and Lead Time

Available stock is generally dispatched within one to three working days after order confirmation, with production lead times advised for larger quantities. Delivery can be arranged by courier, air freight or sea freight, and goods may instead be handed to an appointed forwarder or shipped on the customer’s courier account.


Featured Products


UAE Fiber Optics

UAE office: Abu Dhabi,Al khaleej Al Arabi
Factory add: ZYT industrial area, Shiyan, Baoan district, Shenzhen, China 518000

Popular Products

  • Fiber Optic Patch Cord
  • Fiber Optic Pigtail
  • Fiber Optic Attenuator
  • Fiber Optic Patch Panel
  • Fiber Optic Adapter