OSFP (IHS/Finned Top) to 2x QSFP56-400G-AOC-30M98FT 400G OSFP 8 x 50G PAM4 IHS/Finned Top to 2 x 200G QSFP56 4 x 50G PAM4 Active Optical Breakout Cable, 30m (98ft)

OSFP (IHS/Finned Top) to 2x QSFP56-400G-AOC-30M98FT 400G OSFP 8 x 50G PAM4 IHS/Finned Top to 2 x 200G QSFP56 4 x 50G PAM4 Active Optical Breakout Cable, 30m (98ft)

For data-center links that specify Generic OSFP (IHS/Finned Top) to 2x QSFP56-400G-AOC-30M98FT, this 30m (98ft) AOC assembly delivers 400G connectivity through OSFP (IHS/Finned Top) to 2x QSFP56. It removes separate module-and-patch-cord interfaces while retaining clear mechanical, power and compatibility details for high-density design and installation planning.

OEM Part Number: OSFP (IHS/Finned Top) to 2x QSFP56-400G-AOC-30M98FTHT Part Number: OSFP (IHS/Finned Top) to 2x QSFP56-400G-AOC-30M98FT

Product Highlights

  • HT-manufactured AOC assembly in 30m (98ft)
  • 400G connectivity at 400Gbps
  • Interface configuration: OSFP (IHS/Finned Top) to 2x QSFP56
  • Fixed length and part number: 30m (98ft), OSFP (IHS/Finned Top) to 2x QSFP56-400G-AOC-30M98FT
  • Cable construction: Breakout AOC
  • Maximum power consumption: 10W (OSFP End) 5.5W (QSFP56 Per End)
  • Minimum bend radius: 30mm
  • Operating temperature: 0 to 70°C (32 to 158°F)

Specifications

HT Part NumberOSFP (IHS/Finned Top) to 2x QSFP56-400G-AOC-30M98FT
ManufacturerHT
Form FactorOSFP (IHS/Finned Top) to 2x QSFP56
Max. Data Rate400Gbps
Cable Length30m (98ft)
Cable TypeBreakout AOC
Wavelength850nm
Minimum Bend Radius30mm
Transmitter TypeVSCEL
Receiver TypePIN
Max. Power Consumption10W (OSFP End) 5.5W (QSFP56 Per End)
Jacket MaterialOFNP
Commercial Temperature Range0 to 70°C (32 to 158°F)
Modulation FormatOSFP-8x 50G-PAM4QSFP56-4x 50G-PAM4
Host FECPre-FEC BER 2.4E-4, Post-FEC BER 1E-12
Application400G/200G Ethernet
ProtocolsIEEE 802.3cd, CMIS Rev. 4.0, SFF-8679, SFF-8661, SFF-8636

Signal and Lane Configuration

The listed modulation format is OSFP-8x 50G-PAM4QSFP56-4x 50G-PAM4. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.

Network and Protocol Considerations

The intended application is 400G/200G Ethernet. Listed interface and protocol references include IEEE 802.3cd, CMIS Rev. 4.0, SFF-8679, SFF-8661, SFF-8636. Confirm that the host firmware and port configuration support the same operating mode.

Breakout Port Mapping

The OSFP (IHS/Finned Top) to 2x QSFP56 configuration divides the high-speed interface into multiple lower-speed connections. Verify the upstream lane assignment, downstream port speeds and breakout setting on the host before connecting the assembly. Each branch must attach to the correct remote interface.

Integrated Optical Assembly

The optical engines and fiber are permanently integrated into this AOC. There are no detachable optical modules to clean or exchange. Handle the complete assembly by its connector housings and cable, and keep both ends matched to the same interface specification.

Length Selection and Installation Planning

The installation review for a 30m (98ft) link should include pathway length, support points, connector access and future maintenance. Route the integrated optical cable and both optical engines before attaching both ends, and avoid dragging it across connector panels. A final inspection should confirm that no latch, boot or jacket section carries unnecessary strain. The next shorter verified assembly is OSFP (IHS/Finned Top) to 2x QSFP56-400G-AOC-20M66FT at 20m (66ft), which is the better comparison when the managed route leaves substantial unused cable.

Position Within the Length Range

OSFP (IHS/Finned Top) to 2x QSFP56-400G-AOC-30M98FT is the longest of 6 verified length options in this family. Compared with OSFP (IHS/Finned Top) to 2x QSFP56-400G-AOC-20M66FT at 20m (66ft), it provides 10m of additional reach for a longer vertical drop, a wider rack or an adjacent-cabinet route. Confirm that the complete path requires this length, because unused slack still needs supported, bend-safe storage.

Data-Center Design and Airflow

Select the assembly by both reach and rack layout. A direct connection removes separate module-and-patch-cord interfaces, but it still needs a bend-safe pathway and clear connector access. Keep cable bundles from blocking front-panel airflow, account for the listed interface power where applicable and choose a length that supports maintenance without leaving an unmanaged coil. For this assembly, the minimum bend radius is 30mm; the stated power consumption is 10W (OSFP End) 5.5W (QSFP56 Per End); the jacket material is OFNP.

Power and Thermal Planning

The rated power consumption is 10W (OSFP End) 5.5W (QSFP56 Per End). Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.

Cable Construction and Routing

This assembly uses OFNP jacket, minimum bend radius 30mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.

Quality Assurance and Packaging

Each cable receives connector inspection and a functional link check before it is coiled with bend-safe slack and packed. Protective materials shield the connector housings during transport. Rack or project labels are available to keep length, part number and installation destination aligned. Standard protective packing is used by default, with project documentation arranged when requested.

Ordering Information

Provide the OEM reference, HT part number, fixed length and quantity, together with the intended host interfaces. Rack-based quantities and packaging instructions can be included for larger deployments. Other lengths are separate products and should be entered on their own order lines. Keep OSFP (IHS/Finned Top) to 2x QSFP56-400G-AOC-30M98FT associated with 30m (98ft) throughout the order and receiving record.

Generic Compatibility and Factory Testing

Compatibility confirmation combines host identification with actual link establishment and diagnostic checks. The assembly is prepared for the stated OEM reference rather than selected only by connector shape. For a new data-center deployment, the equipment model, port mode and software release provide the most useful basis for a pre-order review. Where supported by the host, receive activity and diagnostic indications are reviewed together with the established link.

Frequently Asked Questions

Is this an original equipment manufacturer cable?

No. It is manufactured by HT under our own manufacturer identity.

Can excess cable be folded into a compact bundle?

No. Use a supported, bend-safe service loop and observe the listed minimum bend radius. Do not crease the cable or tighten ties around the connector boots.

Will any matching connector operate at the same speed?

Not necessarily. Both hosts must support the stated rate, identification, lane mapping and any required breakout configuration; mechanical compatibility alone is insufficient.

What details assist a compatibility review?

Provide the equipment manufacturer, model, port type, hardware revision and software release, together with the OEM reference, required length and quantity.

Shipping and Lead Time

Standard configurations normally ship within one to three working days, while production quantities are confirmed with the order. Worldwide courier services are available, with air or sea freight for consolidated shipments; freight-collect delivery and coordination with a customer’s logistics provider can be arranged.


Featured Products


UAE Fiber Optics

UAE office: Abu Dhabi,Al khaleej Al Arabi
Factory add: ZYT industrial area, Shiyan, Baoan district, Shenzhen, China 518000

Popular Products

  • Fiber Optic Patch Cord
  • Fiber Optic Pigtail
  • Fiber Optic Attenuator
  • Fiber Optic Patch Panel
  • Fiber Optic Adapter

Products Datasheet

PDF catalogues of our products to download or for general inquiry, please send an email to sales@huihongfiber.com for details.

Customer Support

For customer support, please leave email to sales@huihongfiber.com, we shall reply to you as soon as possible.