OSFP (IHS/Finned Top) to 2x QSFP56-400G-DAC-1.5M5FT 400G OSFP 8 x 50G PAM4 IHS/Finned Top to 2 x 200G QSFP56 4 x 50G PAM4 Passive Copper Breakout Cable, 1.5m (5ft)

OSFP (IHS/Finned Top) to 2x QSFP56-400G-DAC-1.5M5FT 400G OSFP 8 x 50G PAM4 IHS/Finned Top to 2 x 200G QSFP56 4 x 50G PAM4 Passive Copper Breakout Cable, 1.5m (5ft)

For data-center links that specify Generic OSFP (IHS/Finned Top) to 2x QSFP56-400G-DAC-1.5M5FT, this 1.5m (5ft) DAC assembly delivers 400G connectivity through OSFP (IHS/Finned Top) to 2x QSFP56. It removes separate module-and-patch-cord interfaces while retaining clear mechanical, power and compatibility details for high-density design and installation planning.

OEM Part Number: OSFP (IHS/Finned Top) to 2x QSFP56-400G-DAC-1.5M5FTHT Part Number: OSFP (IHS/Finned Top) to 2x QSFP56-400G-DAC-1.5M5FT

Product Highlights

  • HT-manufactured DAC assembly in 1.5m (5ft)
  • 400G connectivity at 400Gbps
  • Interface configuration: OSFP (IHS/Finned Top) to 2x QSFP56
  • Fixed length and part number: 1.5m (5ft), OSFP (IHS/Finned Top) to 2x QSFP56-400G-DAC-1.5M5FT
  • Cable construction: Passive Twinax
  • Conductor specification: 28AWG
  • Maximum power consumption: 0.1W (OSFP End) 0.1W (QSFP56 Per End)
  • Minimum bend radius: 40.5mm

Specifications

HT Part NumberOSFP (IHS/Finned Top) to 2x QSFP56-400G-DAC-1.5M5FT
ManufacturerHT
Form FactorOSFP (IHS/Finned Top) to 2x QSFP56
Max. Data Rate400Gbps
Cable Length1.5m (5ft)
Wire AWG28AWG
Minimum Bend Radius40.5mm
Max. Power Consumption0.1W (OSFP End) 0.1W (QSFP56 Per End)
Cable TypePassive Twinax
Jacket MaterialPVC
Commercial Temperature Range0 to 70°C (32 to 158°F)
ProtocolsOSFP MSA, CMISRev4.0, IEEE802.3cd, SFF-8436, SFF-8665, SFF-8679, SFF-8636
Application400G Ethernet
Modulation TechnologyPAM4

Power and Thermal Planning

The rated power consumption is 0.1W (OSFP End) 0.1W (QSFP56 Per End). Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.

Length Selection and Installation Planning

The additional half metre beyond a one-metre assembly gives OSFP (IHS/Finned Top) to 2x QSFP56-400G-DAC-1.5M5FT useful routing flexibility when the ports are not directly aligned. It can accommodate a different rack unit or a short service loop, but excess cable should be dressed loosely rather than folded into a tight coil.

Position Within the Length Range

OSFP (IHS/Finned Top) to 2x QSFP56-400G-DAC-1.5M5FT occupies the middle of this family between OSFP (IHS/Finned Top) to 2x QSFP56-400G-DAC-1M3FT at 1m (3ft) and CAB-O-2Q-400G-2M at 2m (7ft). It adds 0.5m over the shorter option for extra routing clearance, while the next longer version adds another 0.5m. Measure the managed path and choose this version when its reach is sufficient without creating the slack associated with the longer assembly.

Data-Center Design and Airflow

Select the assembly by both reach and rack layout. A direct connection removes separate module-and-patch-cord interfaces, but it still needs a bend-safe pathway and clear connector access. Keep cable bundles from blocking front-panel airflow, account for the listed interface power where applicable and choose a length that supports maintenance without leaving an unmanaged coil. For this assembly, the listed conductor specification is 28AWG; the minimum bend radius is 40.5mm; the stated power consumption is 0.1W (OSFP End) 0.1W (QSFP56 Per End); the jacket material is PVC.

Cable Construction and Routing

This assembly uses 28AWG conductors, PVC jacket, minimum bend radius 40.5mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.

Network and Protocol Considerations

The intended application is 400G Ethernet. Listed interface and protocol references include OSFP MSA, CMISRev4.0, IEEE802.3cd, SFF-8436, SFF-8665, SFF-8679, SFF-8636. Confirm that the host firmware and port configuration support the same operating mode.

Breakout Port Mapping

The OSFP (IHS/Finned Top) to 2x QSFP56 configuration divides the high-speed interface into multiple lower-speed connections. Verify the upstream lane assignment, downstream port speeds and breakout setting on the host before connecting the assembly. Each branch must attach to the correct remote interface.

Passive Copper Operation

A passive DAC has no separate optical conversion stage. Its low-power, low-latency operation is useful for short equipment links, but the assembly must remain within the length and signaling mode accepted by both hosts.

Quality Assurance and Packaging

Each cable receives connector inspection and a functional link check before it is coiled with bend-safe slack and packed. Protective materials shield the connector housings during transport. Rack or project labels are available to keep length, part number and installation destination aligned. Standard protective packing is used by default, with project documentation arranged when requested.

Ordering Information

Provide the OEM reference, HT part number, fixed length and quantity, together with the intended host interfaces. Rack-based quantities and packaging instructions can be included for larger deployments. Other lengths are separate products and should be entered on their own order lines. This page’s fixed configuration is 1.5m (5ft); another length must be quoted under its corresponding part number.

Generic Compatibility and Factory Testing

Compatibility confirmation combines host identification with actual link establishment and diagnostic checks. The assembly is prepared for the stated OEM reference rather than selected only by connector shape. For a new data-center deployment, the equipment model, port mode and software release provide the most useful basis for a pre-order review. Where supported by the host, link stability and diagnostic indications are reviewed together with the established link.

Frequently Asked Questions

Is this an original equipment manufacturer cable?

No. It is manufactured by HT under our own manufacturer identity.

Can different brands be connected with the same assembly?

Only where both hosts explicitly support the complete interface and compatibility arrangement. Document each end and select the appropriate brand-specific product when required.

Does this order code cover multiple lengths?

No. OSFP (IHS/Finned Top) to 2x QSFP56-400G-DAC-1.5M5FT refers here to 1.5m (5ft). Every other verified length has a separate part number and page in the length list.

Are separate transceivers or patch leads required?

No. This is one complete direct-attach assembly. The ends are not detachable modules and should not be separated from the cable.

Shipping and Lead Time

Standard configurations normally ship within one to three working days, while production quantities are confirmed with the order. International express, air cargo and sea freight can be selected according to destination and carton volume; customer courier accounts and nominated forwarders are also accepted.


Featured Products


UAE Fiber Optics

UAE office: Abu Dhabi,Al khaleej Al Arabi
Factory add: ZYT industrial area, Shiyan, Baoan district, Shenzhen, China 518000

Popular Products

  • Fiber Optic Patch Cord
  • Fiber Optic Pigtail
  • Fiber Optic Attenuator
  • Fiber Optic Patch Panel
  • Fiber Optic Adapter

Products Datasheet

PDF catalogues of our products to download or for general inquiry, please send an email to sales@huihongfiber.com for details.

Customer Support

For customer support, please leave email to sales@huihongfiber.com, we shall reply to you as soon as possible.