This OSFP (IHS/Finned Top) to 4x OSFP (IHS/Finned Top)-800G-DAC-1.5M5FT compatible DAC cable provides a 800G direct connection for Generic equipment in a fixed 1.5m (5ft) configuration. The OSFP (IHS/Finned Top) to 4x OSFP (IHS/Finned Top) assembly integrates both ends and the cable, giving data-center designers one defined product to evaluate for reach, rack layout, airflow and host compatibility.
OEM Part Number: OSFP (IHS/Finned Top) to 4x OSFP (IHS/Finned Top)-800G-DAC-1.5M5FTHT Part Number: OSFP (IHS/Finned Top) to 4x OSFP (IHS/Finned Top)-800G-DAC-1.5M5FT
| HT Part Number | OSFP (IHS/Finned Top) to 4x OSFP (IHS/Finned Top)-800G-DAC-1.5M5FT |
|---|---|
| Manufacturer | HT |
| Form Factor | OSFP (IHS/Finned Top) to 4x OSFP (IHS/Finned Top) |
| Max. Data Rate | 800Gbps |
| Media | Copper |
| Cable Type | Passive Breakout DAC |
| Cable Length | 1.5m (5ft) |
| Wire AWG | 28AWG |
| Minimum Bend Radius | 31mm |
| Max. Power Consumption | 0.1W (800G End), 0.1W (200G Per End) |
| Jacket Material | PVC (OFNR) |
| Commercial Temperature Range | 0 to 70°C (32 to 158°F) |
| Modulation Format | 8x100G-PAM4 to Quad 2x100G-PAM4 |
| Application | 800G/200G Ethernet |
| Protocols | OSFP MSA, CMIS Rev4.0, IEEE 802.3ck |
The listed modulation format is 8x100G-PAM4 to Quad 2x100G-PAM4. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.
The OSFP (IHS/Finned Top) to 4x OSFP (IHS/Finned Top) configuration divides the high-speed interface into multiple lower-speed connections. Verify the upstream lane assignment, downstream port speeds and breakout setting on the host before connecting the assembly. Each branch must attach to the correct remote interface.
A passive DAC has no separate optical conversion stage. Its low-power, low-latency operation is useful for short equipment links, but the assembly must remain within the length and signaling mode accepted by both hosts.
The additional half metre beyond a one-metre assembly gives OSFP (IHS/Finned Top) to 4x OSFP (IHS/Finned Top)-800G-DAC-1.5M5FT useful routing flexibility when the ports are not directly aligned. It can accommodate a different rack unit or a short service loop, but excess cable should be dressed loosely rather than folded into a tight coil.
OSFP (IHS/Finned Top) to 4x OSFP (IHS/Finned Top)-800G-DAC-1.5M5FT occupies the middle of this family between OSFP (IHS/Finned Top) to 4x OSFP (IHS/Finned Top)-800G-DAC-1M3FT at 1m (3ft) and OSFP (IHS/Finned Top) to 4x OSFP (IHS/Finned Top)-800G-DAC-2M7FT at 2m (7ft). It adds 0.5m over the shorter option for extra routing clearance, while the next longer version adds another 0.5m. Measure the managed path and choose this version when its reach is sufficient without creating the slack associated with the longer assembly.
Select the assembly by both reach and rack layout. A direct connection removes separate module-and-patch-cord interfaces, but it still needs a bend-safe pathway and clear connector access. Keep cable bundles from blocking front-panel airflow, account for the listed interface power where applicable and choose a length that supports maintenance without leaving an unmanaged coil. For this assembly, the listed conductor specification is 28AWG; the minimum bend radius is 31mm; the stated power consumption is 0.1W (800G End), 0.1W (200G Per End); the jacket material is PVC (OFNR).
The rated power consumption is 0.1W (800G End), 0.1W (200G Per End). Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.
This assembly uses 28AWG conductors, PVC (OFNR) jacket, minimum bend radius 31mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.
The intended application is 800G/200G Ethernet. Listed interface and protocol references include OSFP MSA, CMIS Rev4.0, IEEE 802.3ck. Confirm that the host firmware and port configuration support the same operating mode.
Each cable receives connector inspection and a functional link check before it is coiled with bend-safe slack and packed. Protective materials shield the connector housings during transport. Rack or project labels are available to keep length, part number and installation destination aligned. Standard protective packing is used by default, with project documentation arranged when requested.
Provide the OEM reference, HT part number, fixed length and quantity, together with the intended host interfaces. Rack-based quantities and packaging instructions can be included for larger deployments. Other lengths are separate products and should be entered on their own order lines. Quantity and any labeling instructions should be attached specifically to OSFP (IHS/Finned Top) to 4x OSFP (IHS/Finned Top)-800G-DAC-1.5M5FT.
Compatibility confirmation combines host identification with actual link establishment and diagnostic checks. The assembly is prepared for the stated OEM reference rather than selected only by connector shape. For a new data-center deployment, the equipment model, port mode and software release provide the most useful basis for a pre-order review. Where supported by the host, link stability and diagnostic indications are reviewed together with the established link.
No. It is manufactured by HT under our own manufacturer identity.
No. This is one complete direct-attach assembly. The ends are not detachable modules and should not be separated from the cable.
No. Use a supported, bend-safe service loop and observe the listed minimum bend radius. Do not crease the cable or tighten ties around the connector boots.
Not necessarily. Both hosts must support the stated rate, identification, lane mapping and any required breakout configuration; mechanical compatibility alone is insufficient.
Standard configurations normally ship within one to three working days, while production quantities are confirmed with the order. International express, air cargo and sea freight can be selected according to destination and carton volume; customer courier accounts and nominated forwarders are also accepted.
800G TransceiversOSFP and QSFP-DD modules for AI data center networks
400G QSFP-DDSR8, DR4, FR4 and LR4 modules and cables
100G QSFP28SR4, CWDM4, LR4 and ER4 transceivers
DAC CablesDirect attach copper cables from 10G up to 800G
AOC CablesActive optical cables for rack-to-rack links
MTP/MPO Trunk Cables8F to 144F multi fiber trunk and harness cables
Fiber Patch CablesOS2, OM3, OM4, OM5 jumpers with LC, SC, FC, ST connectors
Armored Patch CablesStainless steel tube protected fiber patch cords
UAE office: Abu Dhabi,Al khaleej Al Arabi
Factory add: ZYT industrial area, Shiyan, Baoan district, Shenzhen, China 518000