OSFP (IHS/Finned Top) to 4x QSFP56-400G-DAC-2.5M8FT 400G OSFP IHS/Finned Top to 4 x 100G QSFP56 2 x 50G PAM4 Passive Copper Breakout Cable, 2.5m (8ft)

OSFP (IHS/Finned Top) to 4x QSFP56-400G-DAC-2.5M8FT 400G OSFP IHS/Finned Top to 4 x 100G QSFP56 2 x 50G PAM4 Passive Copper Breakout Cable, 2.5m (8ft)

The product on this page is the 2.5m (8ft) version of Generic OSFP (IHS/Finned Top) to 4x QSFP56-400G-DAC-2.5M8FT, built for 400G operation with OSFP (IHS/Finned Top) to 4x QSFP56. Its complete DAC construction simplifies the physical link, and the sections below cover the exact specification, rack-integration considerations and factory verification for this individual order code.

OEM Part Number: OSFP (IHS/Finned Top) to 4x QSFP56-400G-DAC-2.5M8FTHT Part Number: OSFP (IHS/Finned Top) to 4x QSFP56-400G-DAC-2.5M8FT

Product Highlights

  • HT-manufactured DAC assembly in 2.5m (8ft)
  • 400G connectivity at 400Gbps
  • Interface configuration: OSFP (IHS/Finned Top) to 4x QSFP56
  • Fixed length and part number: 2.5m (8ft), OSFP (IHS/Finned Top) to 4x QSFP56-400G-DAC-2.5M8FT
  • Cable construction: Passive Twinax
  • Conductor specification: 28AWG
  • Maximum power consumption: 0.1W (OSFP End) 0.1W (QSFP56 Per End)
  • Minimum bend radius: 30mm

Specifications

HT Part NumberOSFP (IHS/Finned Top) to 4x QSFP56-400G-DAC-2.5M8FT
ManufacturerHT
Form FactorOSFP (IHS/Finned Top) to 4x QSFP56
Max. Data Rate400Gbps
Cable Length2.5m (8ft)
Wire AWG28AWG
Minimum Bend Radius30mm
Max. Power Consumption0.1W (OSFP End) 0.1W (QSFP56 Per End)
MediaCopper
Cable TypePassive Twinax
Modulation Format8x 50G-PAM4 to Quad 2x 50G-PAM4
Jacket MaterialPVC (OFNR)
Temperature Range0 to 70°C (32 to 158°F)
ProtocolsOSFP MSA, IEEE 802.3cd, CMIS v4.0

Signal and Lane Configuration

The listed modulation format is 8x 50G-PAM4 to Quad 2x 50G-PAM4. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.

Cable Construction and Routing

This assembly uses 28AWG conductors, PVC (OFNR) jacket, minimum bend radius 30mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.

Network and Protocol Considerations

The intended application is determined by the host interface and protocol support. Listed interface and protocol references include OSFP MSA, IEEE 802.3cd, CMIS v4.0. Confirm that the host firmware and port configuration support the same operating mode.

Breakout Port Mapping

The OSFP (IHS/Finned Top) to 4x QSFP56 configuration divides the high-speed interface into multiple lower-speed connections. Verify the upstream lane assignment, downstream port speeds and breakout setting on the host before connecting the assembly. Each branch must attach to the correct remote interface.

Passive Copper Operation

A passive DAC has no separate optical conversion stage. Its low-power, low-latency operation is useful for short equipment links, but the assembly must remain within the length and signaling mode accepted by both hosts.

Length Selection and Installation Planning

The 2.5m (8ft) version is useful when a two-metre run would leave insufficient working slack. Before installation, check the complete horizontal and vertical path so that OSFP (IHS/Finned Top) to 4x QSFP56-400G-DAC-2.5M8FT reaches both ports without tension at either connector.

Position Within the Length Range

OSFP (IHS/Finned Top) to 4x QSFP56-400G-DAC-2.5M8FT occupies the middle of this family between OSFP (IHS/Finned Top) to 4x QSFP56-400G-DAC-2M7FT at 2m (7ft) and OSFP (IHS/Finned Top) to 4x QSFP56-400G-DAC-3M10FT at 3m (10ft). It adds 0.5m over the shorter option for extra routing clearance, while the next longer version adds another 0.5m. Measure the managed path and choose this version when its reach is sufficient without creating the slack associated with the longer assembly.

Data-Center Design and Airflow

Select the assembly by both reach and rack layout. A direct connection removes separate module-and-patch-cord interfaces, but it still needs a bend-safe pathway and clear connector access. Keep cable bundles from blocking front-panel airflow, account for the listed interface power where applicable and choose a length that supports maintenance without leaving an unmanaged coil. For this assembly, the listed conductor specification is 28AWG; the minimum bend radius is 30mm; the stated power consumption is 0.1W (OSFP End) 0.1W (QSFP56 Per End); the jacket material is PVC (OFNR).

Power and Thermal Planning

The rated power consumption is 0.1W (OSFP End) 0.1W (QSFP56 Per End). Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.

Quality Assurance and Packaging

Each cable receives connector inspection and a functional link check before it is coiled with bend-safe slack and packed. Protective materials shield the connector housings during transport. Rack or project labels are available to keep length, part number and installation destination aligned. Neutral packaging and customer-specific packing documentation are available on request.

Ordering Information

Provide the OEM reference, HT part number, fixed length and quantity, together with the intended host interfaces. Rack-based quantities and packaging instructions can be included for larger deployments. Other lengths are separate products and should be entered on their own order lines. Keep OSFP (IHS/Finned Top) to 4x QSFP56-400G-DAC-2.5M8FT associated with 2.5m (8ft) throughout the order and receiving record.

Generic Compatibility and Factory Testing

Compatibility confirmation combines host identification with actual link establishment and diagnostic checks. The assembly is prepared for the stated OEM reference rather than selected only by connector shape. For a new data-center deployment, the equipment model, port mode and software release provide the most useful basis for a pre-order review. The check includes link stability and diagnostic indications, followed by a final inspection of both ends.

Frequently Asked Questions

Is this an original equipment manufacturer cable?

No. It is manufactured by HT under our own manufacturer identity.

Does this order code cover multiple lengths?

No. OSFP (IHS/Finned Top) to 4x QSFP56-400G-DAC-2.5M8FT refers here to 2.5m (8ft). Every other verified length has a separate part number and page in the length list.

Are separate transceivers or patch leads required?

No. This is one complete direct-attach assembly. The ends are not detachable modules and should not be separated from the cable.

Can excess cable be folded into a compact bundle?

No. Use a supported, bend-safe service loop and observe the listed minimum bend radius. Do not crease the cable or tighten ties around the connector boots.

Shipping and Lead Time

Standard configurations normally ship within one to three working days, while production quantities are confirmed with the order. Delivery can be arranged by courier, air freight or sea freight, and goods may instead be handed to an appointed forwarder or shipped on the customer’s courier account.


Featured Products


UAE Fiber Optics

UAE office: Abu Dhabi,Al khaleej Al Arabi
Factory add: ZYT industrial area, Shiyan, Baoan district, Shenzhen, China 518000

Popular Products

  • Fiber Optic Patch Cord
  • Fiber Optic Pigtail
  • Fiber Optic Attenuator
  • Fiber Optic Patch Panel
  • Fiber Optic Adapter

Products Datasheet

PDF catalogues of our products to download or for general inquiry, please send an email to sales@huihongfiber.com for details.

Customer Support

For customer support, please leave email to sales@huihongfiber.com, we shall reply to you as soon as possible.