
The product on this page is the 2m (7ft) version of Generic OSFP (RHS/Flat Top) to QSFP-DD-400G-DAC-2M7FT, built for 400G operation with OSFP (RHS/Flat Top) to QSFP-DD. Its complete DAC construction simplifies the physical link, and the sections below cover the exact specification, rack-integration considerations and factory verification for this individual order code.
OEM Part Number: OSFP (RHS/Flat Top) to QSFP-DD-400G-DAC-2M7FTHT Part Number: OSFP (RHS/Flat Top) to QSFP-DD-400G-DAC-2M7FT
| HT Part Number | OSFP (RHS/Flat Top) to QSFP-DD-400G-DAC-2M7FT |
|---|---|
| Manufacturer | HT |
| Form Factor | OSFP (RHS/Flat Top) to QSFP-DD |
| Max Data Rate | 400Gbps |
| Media | Copper |
| Cable Type | Passive Twinax |
| Cable Length | 2m (7ft) |
| Wire AWG | 28AWG |
| Minimum Bend Radius | 40.5mm |
| Power Consumption | ≤0.1W |
| Jacket Material | PVC |
| Temperature | 0 to 70°C (32 to 158°F) |
| Application | 400G Ethernet |
| Modulation Technology | OSFP-4x100GPAM4QDD-4x100GPAM4 |
| Protocols | IEEE 802.3cd, OSFP MSA, QSFP-DD MSA, CMIS Rev4.0, SFF-8417 |
The rated power consumption is ≤0.1W. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.
OSFP (RHS/Flat Top) to QSFP-DD-400G-DAC-2M7FT provides 2m (7ft) for connections between separated rack units or nearby equipment positions. Plan the route around cable managers and power cords, keeping the assembly free from connector strain while avoiding a large obstruction in the airflow path.
OSFP (RHS/Flat Top) to QSFP-DD-400G-DAC-2M7FT is the longest of 4 verified length options in this family. Compared with OSFP (RHS/Flat Top) to QSFP-DD-400G-DAC-1.5M5FT at 1.5m (5ft), it provides 0.5m of additional reach for a longer vertical drop, a wider rack or an adjacent-cabinet route. Confirm that the complete path requires this length, because unused slack still needs supported, bend-safe storage.
Select the assembly by both reach and rack layout. A direct connection removes separate module-and-patch-cord interfaces, but it still needs a bend-safe pathway and clear connector access. Keep cable bundles from blocking front-panel airflow, account for the listed interface power where applicable and choose a length that supports maintenance without leaving an unmanaged coil. For this assembly, the listed conductor specification is 28AWG; the minimum bend radius is 40.5mm; the stated power consumption is ≤0.1W; the jacket material is PVC.
This assembly uses 28AWG conductors, PVC jacket, minimum bend radius 40.5mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.
The intended application is 400G Ethernet. Listed interface and protocol references include IEEE 802.3cd, OSFP MSA, QSFP-DD MSA, CMIS Rev4.0, SFF-8417. Confirm that the host firmware and port configuration support the same operating mode.
A passive DAC has no separate optical conversion stage. Its low-power, low-latency operation is useful for short equipment links, but the assembly must remain within the length and signaling mode accepted by both hosts.
Each cable receives connector inspection and a functional link check before it is coiled with bend-safe slack and packed. Protective materials shield the connector housings during transport. Rack or project labels are available to keep length, part number and installation destination aligned. Standard protective packing is used by default, with project documentation arranged when requested.
Provide the OEM reference, HT part number, fixed length and quantity, together with the intended host interfaces. Rack-based quantities and packaging instructions can be included for larger deployments. Other lengths are separate products and should be entered on their own order lines. This page’s fixed configuration is 2m (7ft); another length must be quoted under its corresponding part number.
Compatibility confirmation combines host identification with actual link establishment and diagnostic checks. The assembly is prepared for the stated OEM reference rather than selected only by connector shape. For a new data-center deployment, the equipment model, port mode and software release provide the most useful basis for a pre-order review. The check includes link stability and diagnostic indications, followed by a final inspection of both ends.
No. It is manufactured by HT under our own manufacturer identity.
No. Use a supported, bend-safe service loop and observe the listed minimum bend radius. Do not crease the cable or tighten ties around the connector boots.
Not necessarily. Both hosts must support the stated rate, identification, lane mapping and any required breakout configuration; mechanical compatibility alone is insufficient.
Provide the equipment manufacturer, model, port type, hardware revision and software release, together with the OEM reference, required length and quantity.
Available stock is generally dispatched within one to three working days after order confirmation, with production lead times advised for larger quantities. Delivery can be arranged by courier, air freight or sea freight, and goods may instead be handed to an appointed forwarder or shipped on the customer’s courier account.
800G TransceiversOSFP and QSFP-DD modules for AI data center networks
400G QSFP-DDSR8, DR4, FR4 and LR4 modules and cables
100G QSFP28SR4, CWDM4, LR4 and ER4 transceivers
DAC CablesDirect attach copper cables from 10G up to 800G
AOC CablesActive optical cables for rack-to-rack links
MTP/MPO Trunk Cables8F to 144F multi fiber trunk and harness cables
Fiber Patch CablesOS2, OM3, OM4, OM5 jumpers with LC, SC, FC, ST connectors
Armored Patch CablesStainless steel tube protected fiber patch cords
UAE office: Abu Dhabi,Al khaleej Al Arabi
Factory add: ZYT industrial area, Shiyan, Baoan district, Shenzhen, China 518000