Cisco QDD-4ZQ100-CU1M Compatible 400G QSFP-DD 8 x 50G PAM4 to 4 x 100G QSFP56 2 x 50G PAM4 Passive Copper Breakout Cable, 1m (3ft)

Cisco QDD-4ZQ100-CU1M Compatible 400G QSFP-DD 8 x 50G PAM4 to 4 x 100G QSFP56 2 x 50G PAM4 Passive Copper Breakout Cable, 1m (3ft)

The product on this page is the 1m (3ft) version of Cisco QDD-4ZQ100-CU1M, built for 400G operation with QSFP-DD to 4x QSFP56. Its complete DAC construction simplifies the physical link, and the sections below cover the exact specification, rack-integration considerations and factory verification for this individual order code.

OEM Part Number: QDD-4ZQ100-CU1MHT Part Number: QDD-4ZQ100-CU1M

Product Highlights

  • Compatible alternative to Cisco QDD-4ZQ100-CU1M
  • 400G connectivity at 400Gbps
  • Interface configuration: QSFP-DD to 4x QSFP56
  • Fixed length and part number: 1m (3ft), QDD-4ZQ100-CU1M
  • Conductor specification: 30AWG
  • Maximum power consumption: 0.1W (QSFP-DD End)0.1W (QSFP56 Per End)
  • Minimum bend radius: 35mm
  • Operating temperature: 0 to 70°C (32 to 158°F)

Specifications

HT Part NumberQDD-4ZQ100-CU1M
Cisco CompatibleQDD-4ZQ100-CU1M
ManufacturerHT
Form FactorQSFP-DD to 4x QSFP56
Max. Data Rate400Gbps
Minimum Bend Radius35mm
Wire AWG30AWG
Cable Length1m (3ft)
Jacket MaterialPVC
MediaCopper
Modulation FormatQSFP-DD-8x 50G-PAM4QSFP56-2x 50G-PAM4
Commercial Temperature Range0 to 70°C (32 to 158°F)
Power Supply3.3V
ProtocolsSFF-8665, QSFP-DD MSA, IEEE802.3bj, IEEE802.3 cd
Max. Power Consumption0.1W (QSFP-DD End)0.1W (QSFP56 Per End)
Application400G Ethernet

Signal and Lane Configuration

The listed modulation format is QSFP-DD-8x 50G-PAM4QSFP56-2x 50G-PAM4. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.

Length Selection and Installation Planning

At 1m (3ft), QDD-4ZQ100-CU1M is a practical choice for direct connections within one rack. Route the cable along the intended management path rather than pulling it diagonally across adjacent connectors, and leave enough clearance for insertion, removal and front-panel airflow.

Position Within the Length Range

QDD-4ZQ100-CU1M occupies the middle of this family between QDD-4ZQ100-CU0.5M at 0.5m (2ft) and QDD-4ZQ100-CU1.5M at 1.5m (5ft). It adds 0.5m over the shorter option for extra routing clearance, while the next longer version adds another 0.5m. Measure the managed path and choose this version when its reach is sufficient without creating the slack associated with the longer assembly.

Data-Center Design and Airflow

Select the assembly by both reach and rack layout. A direct connection removes separate module-and-patch-cord interfaces, but it still needs a bend-safe pathway and clear connector access. Keep cable bundles from blocking front-panel airflow, account for the listed interface power where applicable and choose a length that supports maintenance without leaving an unmanaged coil. For this assembly, the listed conductor specification is 30AWG; the minimum bend radius is 35mm; the stated power consumption is 0.1W (QSFP-DD End)0.1W (QSFP56 Per End); the jacket material is PVC.

Power and Thermal Planning

The rated power consumption is 0.1W (QSFP-DD End)0.1W (QSFP56 Per End). Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.

Cable Construction and Routing

This assembly uses 30AWG conductors, PVC jacket, minimum bend radius 35mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.

Network and Protocol Considerations

The intended application is 400G Ethernet. Listed interface and protocol references include SFF-8665, QSFP-DD MSA, IEEE802.3bj, IEEE802.3 cd. Confirm that the host firmware and port configuration support the same operating mode.

Breakout Port Mapping

The QSFP-DD to 4x QSFP56 configuration divides the high-speed interface into multiple lower-speed connections. Verify the upstream lane assignment, downstream port speeds and breakout setting on the host before connecting the assembly. Each branch must attach to the correct remote interface.

Passive Copper Operation

A passive DAC has no separate optical conversion stage. Its low-power, low-latency operation is useful for short equipment links, but the assembly must remain within the length and signaling mode accepted by both hosts.

Quality Assurance and Packaging

Each cable receives connector inspection and a functional link check before it is coiled with bend-safe slack and packed. Protective materials shield the connector housings during transport. Rack or project labels are available to keep length, part number and installation destination aligned. Standard protective packing is used by default, with project documentation arranged when requested.

Ordering Information

Provide the OEM reference, HT part number, fixed length and quantity, together with the intended host interfaces. Rack-based quantities and packaging instructions can be included for larger deployments. Other lengths are separate products and should be entered on their own order lines. This page’s fixed configuration is 1m (3ft); another length must be quoted under its corresponding part number.

Cisco Compatibility and Factory Testing

Compatibility confirmation combines host identification with actual link establishment and diagnostic checks. The assembly is prepared for the stated OEM reference rather than selected only by connector shape. For a new data-center deployment, the equipment model, port mode and software release provide the most useful basis for a pre-order review. Both connectors are examined before the operating test, which includes link stability and diagnostic indications.

Frequently Asked Questions

Is this an original Cisco cable?

No. It is an HT-manufactured compatible alternative for equipment that specifies Cisco QDD-4ZQ100-CU1M.

Are separate transceivers or patch leads required?

No. This is one complete direct-attach assembly. The ends are not detachable modules and should not be separated from the cable.

Can excess cable be folded into a compact bundle?

No. Use a supported, bend-safe service loop and observe the listed minimum bend radius. Do not crease the cable or tighten ties around the connector boots.

Will any matching connector operate at the same speed?

Not necessarily. Both hosts must support the stated rate, identification, lane mapping and any required breakout configuration; mechanical compatibility alone is insufficient.

Shipping and Lead Time

Available stock is generally dispatched within one to three working days after order confirmation, with production lead times advised for larger quantities. International express, air cargo and sea freight can be selected according to destination and carton volume; customer courier accounts and nominated forwarders are also accepted.


Featured Products


UAE Fiber Optics

UAE office: Abu Dhabi,Al khaleej Al Arabi
Factory add: ZYT industrial area, Shiyan, Baoan district, Shenzhen, China 518000

Popular Products

  • Fiber Optic Patch Cord
  • Fiber Optic Pigtail
  • Fiber Optic Attenuator
  • Fiber Optic Patch Panel
  • Fiber Optic Adapter

Products Datasheet

PDF catalogues of our products to download or for general inquiry, please send an email to sales@huihongfiber.com for details.

Customer Support

For customer support, please leave email to sales@huihongfiber.com, we shall reply to you as soon as possible.