
The QDD-800G-AE compatible series is designed for Arista Networks hosts requiring a 800G AEC connection. Its QSFP-DD to QSFP-DD arrangement is supplied as an active electrical assembly intended for hosts supporting the stated retimed interface. Use the specifications to assess the physical assembly, then follow the exact length and part-number links when preparing a bill of materials or requesting a compatibility check.
Series Part Number: QDD-800G-AEHT Part Number: QDD-800G-AE
The documented series configuration is 2m (7ft). Use the relevant OEM reference below together with the HT identity and required length when requesting a quotation. If another length carries a different OEM part number, it must be reviewed and ordered as that distinct configuration.
| HT Part Number | QDD-800G-AE |
|---|---|
| Manufacturer | HT |
| Form Factor | QSFP-DD to QSFP-DD |
| Max. Data Rate | 800Gbps |
| Media | Copper |
| Cable Type | Active DAC (AEC) |
| Cable Length Options Covered | 2m (7ft) |
| Jacket Material | PET |
| Minimum Bend Radius | 36.5 |
| Wire AWG | 32AWG |
| Max. Power Consumption | 12W Per End |
| Modulation Format | 8x100G-PAM4 |
| Commercial Temperature Range | 0 to 70°C (32 to 158°F) |
| Application | 800G Ethernet |
| Protocols | CMIS 5.0, IEEE 802.3ck, QSFP-DD MSA Rev6.3 |
For an AEC connection, matching the connector shape is only the first step. The host must support the electrical signaling, retiming behavior and aggregate rate of the complete assembly. Thermal planning is particularly important when many active ends populate adjacent ports. For this series, the listed interface is QSFP-DD to QSFP-DD and the aggregate rate is 800G. The stated application is 800G Ethernet.
Each cable receives connector inspection and a functional link check before it is coiled with bend-safe slack and packed. Protective materials shield the connector housings during transport. Rack or project labels are available to keep length, part number and installation destination aligned. Both connector ends are inspected as part of the complete assembly, and protective packing is selected to avoid tight bends during transport and storage.
The specification table records the conductor specification is 32AWG; the jacket material is PET; the minimum bend radius is 36.5; the operating temperature is 0 to 70°C (32 to 158°F); the power consumption is 12W Per End. Use those values when preparing the rack pathway and receiving checklist. Do not pull a connector by its cable, compress the run under tight ties or force excess length into a sharp coil. Connector protection should remain in place until the assembly is ready for insertion.
Select the assembly by both reach and rack layout. A direct connection removes separate module-and-patch-cord interfaces, but it still needs a bend-safe pathway and clear connector access. Keep cable bundles from blocking front-panel airflow, account for the listed interface power where applicable and choose a length that supports maintenance without leaving an unmanaged coil. For this series, keep the interface rate, AEC construction and length-specific OEM reference together throughout that review.
Provide the OEM reference, HT part number, fixed length and quantity, together with the intended host interfaces. Rack-based quantities and packaging instructions can be included for larger deployments. Other lengths are separate products and should be entered on their own order lines. For this series, follow the corresponding length link, quote that exact OEM part number and keep different lengths on separate order lines. HT part number QDD-800G-AE identifies the product family; the linked page provides the final length-specific identity.
Compatibility confirmation combines host identification with actual link establishment and diagnostic checks. The assembly is prepared for the stated OEM reference rather than selected only by connector shape. For a new data-center deployment, the equipment model, port mode and software release provide the most useful basis for a pre-order review. Series-level inspection is followed by the exact length and OEM configuration selected for dispatch. Functional verification includes link establishment and diagnostic indications where the host exposes them.
Standard configurations normally ship within one to three working days, with production lead times confirmed for larger quantities. International courier, air freight and sea freight are available; customer courier accounts and nominated forwarders are accepted.
No. It is an HT-manufactured compatible cable for equipment that specifies QDD-800G-AE, not an original Arista Networks-branded product.
Yes. Where a length has its own OEM reference, follow the corresponding link above and order that exact part number on its own line. Do not substitute another length only because the connector arrangement is the same.
No. The connector ends and cable form one complete direct-attach assembly. The ends are not detachable standalone transceivers, and the complete product is tested together.
Provide the equipment manufacturer and model, port type, hardware revision and software release, together with the required OEM reference, length and quantity. Breakout projects should also identify the intended lane configuration.
800G TransceiversOSFP and QSFP-DD modules for AI data center networks
400G QSFP-DDSR8, DR4, FR4 and LR4 modules and cables
100G QSFP28SR4, CWDM4, LR4 and ER4 transceivers
DAC CablesDirect attach copper cables from 10G up to 800G
AOC CablesActive optical cables for rack-to-rack links
MTP/MPO Trunk Cables8F to 144F multi fiber trunk and harness cables
Fiber Patch CablesOS2, OM3, OM4, OM5 jumpers with LC, SC, FC, ST connectors
Armored Patch CablesStainless steel tube protected fiber patch cords
UAE office: Abu Dhabi,Al khaleej Al Arabi
Factory add: ZYT industrial area, Shiyan, Baoan district, Shenzhen, China 518000