QSFP-DD to 4x QSFP28-200G-DAC-1.5M5FT 200G QSFP-DD 8 x 25G NRZ to 4 x 50G QSFP28 2 x 25G NRZ Passive Copper Breakout Cable, 1.5m (5ft)

QSFP-DD to 4x QSFP28-200G-DAC-1.5M5FT 200G QSFP-DD 8 x 25G NRZ to 4 x 50G QSFP28 2 x 25G NRZ Passive Copper Breakout Cable, 1.5m (5ft)

The product on this page is the 1.5m (5ft) version of Generic QSFP-DD to 4x QSFP28-200G-DAC-1.5M5FT, built for 200G operation with QSFP-DD to 4x QSFP28. Its complete DAC construction simplifies the physical link, and the sections below cover the exact specification, rack-integration considerations and factory verification for this individual order code.

OEM Part Number: QSFP-DD to 4x QSFP28-200G-DAC-1.5M5FTHT Part Number: QSFP-DD to 4x QSFP28-200G-DAC-1.5M5FT

Product Highlights

  • HT-manufactured DAC assembly in 1.5m (5ft)
  • 200G connectivity at 200G
  • Interface configuration: QSFP-DD to 4x QSFP28
  • Fixed length and part number: 1.5m (5ft), QSFP-DD to 4x QSFP28-200G-DAC-1.5M5FT
  • Conductor specification: 28 AWG
  • Minimum bend radius: 10mm
  • Operating temperature: 0 to 70°C (32 to 158°F)

Specifications

HT Part NumberQSFP-DD to 4x QSFP28-200G-DAC-1.5M5FT
ManufacturerHT
Connector TypeQSFP-DD to 4x QSFP28
Max Data Rate200G
Minimum Bend Radius10mm
Wire AWG28 AWG
Cable Length3m (10ft)
Jacket MaterialPVC
Operating Temperature0 to 70°C (32 to 158°F)
Storage Temperature-40°C to 85°C (-40°F to 185°F)
Modulation FormatNRZ
ProtocolsQSFP-DD MSA Rev. 5.0, CMIS Rev 4.0, IEEE 802.3cd

Signal and Lane Configuration

The listed modulation format is NRZ. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.

Passive Copper Operation

A passive DAC has no separate optical conversion stage. Its low-power, low-latency operation is useful for short equipment links, but the assembly must remain within the length and signaling mode accepted by both hosts.

Length Selection and Installation Planning

The additional half metre beyond a one-metre assembly gives QSFP-DD to 4x QSFP28-200G-DAC-1.5M5FT useful routing flexibility when the ports are not directly aligned. It can accommodate a different rack unit or a short service loop, but excess cable should be dressed loosely rather than folded into a tight coil.

Position Within the Length Range

QSFP-DD to 4x QSFP28-200G-DAC-1.5M5FT occupies the middle of this family between QSFP-DD to 4x QSFP28-200G-DAC-1M3FT at 1m (3ft) and QSFP-DD to 4x QSFP28-200G-DAC-2M7FT at 2m (7ft). It adds 0.5m over the shorter option for extra routing clearance, while the next longer version adds another 0.5m. Measure the managed path and choose this version when its reach is sufficient without creating the slack associated with the longer assembly.

Data-Center Design and Airflow

Select the assembly by both reach and rack layout. A direct connection removes separate module-and-patch-cord interfaces, but it still needs a bend-safe pathway and clear connector access. Keep cable bundles from blocking front-panel airflow, account for the listed interface power where applicable and choose a length that supports maintenance without leaving an unmanaged coil. For this assembly, the listed conductor specification is 28 AWG; the minimum bend radius is 10mm; the jacket material is PVC.

Cable Construction and Routing

This assembly uses 28 AWG conductors, PVC jacket, minimum bend radius 10mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.

Network and Protocol Considerations

The intended application is determined by the host interface and protocol support. Listed interface and protocol references include QSFP-DD MSA Rev. 5.0, CMIS Rev 4.0, IEEE 802.3cd. Confirm that the host firmware and port configuration support the same operating mode.

Breakout Port Mapping

The QSFP-DD to 4x QSFP28 configuration divides the high-speed interface into multiple lower-speed connections. Verify the upstream lane assignment, downstream port speeds and breakout setting on the host before connecting the assembly. Each branch must attach to the correct remote interface.

Quality Assurance and Packaging

Each cable receives connector inspection and a functional link check before it is coiled with bend-safe slack and packed. Protective materials shield the connector housings during transport. Rack or project labels are available to keep length, part number and installation destination aligned. Volume orders can include customer references on the labels and carton list.

Ordering Information

Provide the OEM reference, HT part number, fixed length and quantity, together with the intended host interfaces. Rack-based quantities and packaging instructions can be included for larger deployments. Other lengths are separate products and should be entered on their own order lines. This page’s fixed configuration is 1.5m (5ft); another length must be quoted under its corresponding part number.

Generic Compatibility and Factory Testing

Compatibility confirmation combines host identification with actual link establishment and diagnostic checks. The assembly is prepared for the stated OEM reference rather than selected only by connector shape. For a new data-center deployment, the equipment model, port mode and software release provide the most useful basis for a pre-order review. The check includes link stability and diagnostic indications, followed by a final inspection of both ends.

Frequently Asked Questions

Is this an original equipment manufacturer cable?

No. It is manufactured by HT under our own manufacturer identity.

Can different brands be connected with the same assembly?

Only where both hosts explicitly support the complete interface and compatibility arrangement. Document each end and select the appropriate brand-specific product when required.

Does this order code cover multiple lengths?

No. QSFP-DD to 4x QSFP28-200G-DAC-1.5M5FT refers here to 1.5m (5ft). Every other verified length has a separate part number and page in the length list.

Are separate transceivers or patch leads required?

No. This is one complete direct-attach assembly. The ends are not detachable modules and should not be separated from the cable.

Shipping and Lead Time

Available stock is generally dispatched within one to three working days after order confirmation, with production lead times advised for larger quantities. Worldwide courier services are available, with air or sea freight for consolidated shipments; freight-collect delivery and coordination with a customer’s logistics provider can be arranged.


Featured Products


UAE Fiber Optics

UAE office: Abu Dhabi,Al khaleej Al Arabi
Factory add: ZYT industrial area, Shiyan, Baoan district, Shenzhen, China 518000

Popular Products

  • Fiber Optic Patch Cord
  • Fiber Optic Pigtail
  • Fiber Optic Attenuator
  • Fiber Optic Patch Panel
  • Fiber Optic Adapter

Products Datasheet

PDF catalogues of our products to download or for general inquiry, please send an email to sales@huihongfiber.com for details.

Customer Support

For customer support, please leave email to sales@huihongfiber.com, we shall reply to you as soon as possible.