QSFP-DD to 8x SFP28-200G-DAC-1M3FT 200G QSFP-DD 8 x 25G NRZ to 8 x 25G SFP28 25G NRZ Passive Copper Breakout Cable, 1m (3ft)

QSFP-DD to 8x SFP28-200G-DAC-1M3FT 200G QSFP-DD 8 x 25G NRZ to 8 x 25G SFP28 25G NRZ Passive Copper Breakout Cable, 1m (3ft)

For data-center links that specify Generic QSFP-DD to 8x SFP28-200G-DAC-1M3FT, this 1m (3ft) DAC assembly delivers 200G connectivity through QSFP-DD to 8x SFP28. It removes separate module-and-patch-cord interfaces while retaining clear mechanical, power and compatibility details for high-density design and installation planning.

OEM Part Number: QSFP-DD to 8x SFP28-200G-DAC-1M3FTHT Part Number: QSFP-DD to 8x SFP28-200G-DAC-1M3FT

Product Highlights

  • HT-manufactured DAC assembly in 1m (3ft)
  • 200G connectivity at 200Gbps
  • Interface configuration: QSFP-DD to 8x SFP28
  • Fixed length and part number: 1m (3ft), QSFP-DD to 8x SFP28-200G-DAC-1M3FT
  • Cable construction: Passive Breakout DAC
  • Conductor specification: 30AWG
  • Maximum power consumption: 0.1W (QSFP-DD End)0.1W (SFP28 Per End)
  • Minimum bend radius: 20.5mm

Specifications

HT Part NumberQSFP-DD to 8x SFP28-200G-DAC-1M3FT
ManufacturerHT
Form FactorQSFP-DD to 8x SFP28
Max. Data Rate200Gbps
MediaCopper
Cable TypePassive Breakout DAC
Minimum Bend Radius20.5mm
Wire AWG30AWG
Cable Length1m (3ft)
Jacket MaterialPVC (OFNR)
Max. Power Consumption0.1W (QSFP-DD End)0.1W (SFP28 Per End)
Modulation FormatQSFP-DD-8x 25G-NRZSFP28-25G-NRZ
DDM/DOMNot Supported
Commercial TemperatureRange0 to 70°C (32 to 158°F)
ProtocolsQSFP-DD MSA, SFF-8432, IEEE 802.3bs-200GAUI-8, IEEE802.3by-25GAUI, CMIS 4.0, SFF-8472

Signal and Lane Configuration

The listed modulation format is QSFP-DD-8x 25G-NRZSFP28-25G-NRZ. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.

Position Within the Length Range

QSFP-DD to 8x SFP28-200G-DAC-1M3FT occupies the middle of this family between QSFP-DD to 8x SFP28-200G-DAC-0.5M2FT at 0.5m (2ft) and QSFP-DD to 8x SFP28-200G-DAC-1.5M5FT at 1.5m (5ft). It adds 0.5m over the shorter option for extra routing clearance, while the next longer version adds another 0.5m. Measure the managed path and choose this version when its reach is sufficient without creating the slack associated with the longer assembly.

Data-Center Design and Airflow

Select the assembly by both reach and rack layout. A direct connection removes separate module-and-patch-cord interfaces, but it still needs a bend-safe pathway and clear connector access. Keep cable bundles from blocking front-panel airflow, account for the listed interface power where applicable and choose a length that supports maintenance without leaving an unmanaged coil. For this assembly, the listed conductor specification is 30AWG; the minimum bend radius is 20.5mm; the stated power consumption is 0.1W (QSFP-DD End)0.1W (SFP28 Per End); the jacket material is PVC (OFNR).

Power and Thermal Planning

The rated power consumption is 0.1W (QSFP-DD End)0.1W (SFP28 Per End). Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.

Cable Construction and Routing

This assembly uses 30AWG conductors, PVC (OFNR) jacket, minimum bend radius 20.5mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.

Network and Protocol Considerations

The intended application is determined by the host interface and protocol support. Listed interface and protocol references include QSFP-DD MSA, SFF-8432, IEEE 802.3bs-200GAUI-8, IEEE802.3by-25GAUI, CMIS 4.0, SFF-8472. Confirm that the host firmware and port configuration support the same operating mode.

Breakout Port Mapping

The QSFP-DD to 8x SFP28 configuration divides the high-speed interface into multiple lower-speed connections. Verify the upstream lane assignment, downstream port speeds and breakout setting on the host before connecting the assembly. Each branch must attach to the correct remote interface.

Passive Copper Operation

A passive DAC has no separate optical conversion stage. Its low-power, low-latency operation is useful for short equipment links, but the assembly must remain within the length and signaling mode accepted by both hosts.

Length Selection and Installation Planning

At 1m (3ft), QSFP-DD to 8x SFP28-200G-DAC-1M3FT is a practical choice for direct connections within one rack. Route the cable along the intended management path rather than pulling it diagonally across adjacent connectors, and leave enough clearance for insertion, removal and front-panel airflow.

Quality Assurance and Packaging

Each cable receives connector inspection and a functional link check before it is coiled with bend-safe slack and packed. Protective materials shield the connector housings during transport. Rack or project labels are available to keep length, part number and installation destination aligned. Volume orders can include customer references on the labels and carton list.

Ordering Information

Provide the OEM reference, HT part number, fixed length and quantity, together with the intended host interfaces. Rack-based quantities and packaging instructions can be included for larger deployments. Other lengths are separate products and should be entered on their own order lines. Keep QSFP-DD to 8x SFP28-200G-DAC-1M3FT associated with 1m (3ft) throughout the order and receiving record.

Generic Compatibility and Factory Testing

Compatibility confirmation combines host identification with actual link establishment and diagnostic checks. The assembly is prepared for the stated OEM reference rather than selected only by connector shape. For a new data-center deployment, the equipment model, port mode and software release provide the most useful basis for a pre-order review. Both connectors are examined before the operating test, which includes link stability and diagnostic indications.

Frequently Asked Questions

Is this an original equipment manufacturer cable?

No. It is manufactured by HT under our own manufacturer identity.

How should an unused assembly be stored?

Protect both connector ends, keep the cable in a loose bend-safe coil and retain its part-number label so the length and compatibility identity remain traceable.

Can different brands be connected with the same assembly?

Only where both hosts explicitly support the complete interface and compatibility arrangement. Document each end and select the appropriate brand-specific product when required.

Does this order code cover multiple lengths?

No. QSFP-DD to 8x SFP28-200G-DAC-1M3FT refers here to 1m (3ft). Every other verified length has a separate part number and page in the length list.

Shipping and Lead Time

Available stock is generally dispatched within one to three working days after order confirmation, with production lead times advised for larger quantities. Worldwide courier services are available, with air or sea freight for consolidated shipments; freight-collect delivery and coordination with a customer’s logistics provider can be arranged.


Featured Products


UAE Fiber Optics

UAE office: Abu Dhabi,Al khaleej Al Arabi
Factory add: ZYT industrial area, Shiyan, Baoan district, Shenzhen, China 518000

Popular Products

  • Fiber Optic Patch Cord
  • Fiber Optic Pigtail
  • Fiber Optic Attenuator
  • Fiber Optic Patch Panel
  • Fiber Optic Adapter

Products Datasheet

PDF catalogues of our products to download or for general inquiry, please send an email to sales@huihongfiber.com for details.

Customer Support

For customer support, please leave email to sales@huihongfiber.com, we shall reply to you as soon as possible.