QSFP-DD to 8x SFP28-200G-DAC-3M10FT 200G QSFP-DD 8 x 25G NRZ to 8 x 25G SFP28 25G NRZ Passive Copper Breakout Cable, 3m (10ft)

QSFP-DD to 8x SFP28-200G-DAC-3M10FT 200G QSFP-DD 8 x 25G NRZ to 8 x 25G SFP28 25G NRZ Passive Copper Breakout Cable, 3m (10ft)

For data-center links that specify Generic QSFP-DD to 8x SFP28-200G-DAC-3M10FT, this 3m (10ft) DAC assembly delivers 200G connectivity through QSFP-DD to 8x SFP28. It removes separate module-and-patch-cord interfaces while retaining clear mechanical, power and compatibility details for high-density design and installation planning.

OEM Part Number: QSFP-DD to 8x SFP28-200G-DAC-3M10FTHT Part Number: QSFP-DD to 8x SFP28-200G-DAC-3M10FT

Product Highlights

  • HT-manufactured DAC assembly in 3m (10ft)
  • 200G connectivity at 200Gbps
  • Interface configuration: QSFP-DD to 8x SFP28
  • Fixed length and part number: 3m (10ft), QSFP-DD to 8x SFP28-200G-DAC-3M10FT
  • Cable construction: Passive Breakout DAC
  • Conductor specification: 28AWG
  • Maximum power consumption: 0.1W (QSFP-DD End)0.1W (SFP28 Per End)
  • Minimum bend radius: 22.5mm

Specifications

HT Part NumberQSFP-DD to 8x SFP28-200G-DAC-3M10FT
ManufacturerHT
Form FactorQSFP-DD to 8x SFP28
Max. Data Rate200Gbps
MediaCopper
Cable TypePassive Breakout DAC
Minimum Bend Radius22.5mm
Wire AWG28AWG
Cable Length3m (10ft)
Jacket MaterialPVC (OFNR)
Max. Power Consumption0.1W (QSFP-DD End)0.1W (SFP28 Per End)
Modulation FormatQSFP-DD-8x 25G-NRZSFP28-25G-NRZ
DDM/DOMNot Supported
Commercial TemperatureRange0 to 70°C (32 to 158°F)
ProtocolsQSFP-DD MSA, SFF-8432, IEEE 802.3bs-200GAUI-8, IEEE802.3by-25GAUI, CMIS 4.0, SFF-8472

Signal and Lane Configuration

The listed modulation format is QSFP-DD-8x 25G-NRZSFP28-25G-NRZ. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.

Position Within the Length Range

QSFP-DD to 8x SFP28-200G-DAC-3M10FT is the longest of 6 verified length options in this family. Compared with QSFP-DD to 8x SFP28-200G-DAC-2.5M8FT at 2.5m (8ft), it provides 0.5m of additional reach for a longer vertical drop, a wider rack or an adjacent-cabinet route. Confirm that the complete path requires this length, because unused slack still needs supported, bend-safe storage.

Data-Center Design and Airflow

Select the assembly by both reach and rack layout. A direct connection removes separate module-and-patch-cord interfaces, but it still needs a bend-safe pathway and clear connector access. Keep cable bundles from blocking front-panel airflow, account for the listed interface power where applicable and choose a length that supports maintenance without leaving an unmanaged coil. For this assembly, the listed conductor specification is 28AWG; the minimum bend radius is 22.5mm; the stated power consumption is 0.1W (QSFP-DD End)0.1W (SFP28 Per End); the jacket material is PVC (OFNR).

Power and Thermal Planning

The rated power consumption is 0.1W (QSFP-DD End)0.1W (SFP28 Per End). Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.

Cable Construction and Routing

This assembly uses 28AWG conductors, PVC (OFNR) jacket, minimum bend radius 22.5mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.

Network and Protocol Considerations

The intended application is determined by the host interface and protocol support. Listed interface and protocol references include QSFP-DD MSA, SFF-8432, IEEE 802.3bs-200GAUI-8, IEEE802.3by-25GAUI, CMIS 4.0, SFF-8472. Confirm that the host firmware and port configuration support the same operating mode.

Breakout Port Mapping

The QSFP-DD to 8x SFP28 configuration divides the high-speed interface into multiple lower-speed connections. Verify the upstream lane assignment, downstream port speeds and breakout setting on the host before connecting the assembly. Each branch must attach to the correct remote interface.

Passive Copper Operation

A passive DAC has no separate optical conversion stage. Its low-power, low-latency operation is useful for short equipment links, but the assembly must remain within the length and signaling mode accepted by both hosts.

Length Selection and Installation Planning

At 3m (10ft), this assembly can bridge non-aligned ports or adjacent racks while remaining a single direct-attach link. Support longer horizontal runs with suitable cable management and preserve space for cooling and future maintenance.

Quality Assurance and Packaging

Each cable receives connector inspection and a functional link check before it is coiled with bend-safe slack and packed. Protective materials shield the connector housings during transport. Rack or project labels are available to keep length, part number and installation destination aligned. Neutral packaging and customer-specific packing documentation are available on request.

Ordering Information

Provide the OEM reference, HT part number, fixed length and quantity, together with the intended host interfaces. Rack-based quantities and packaging instructions can be included for larger deployments. Other lengths are separate products and should be entered on their own order lines. Keep QSFP-DD to 8x SFP28-200G-DAC-3M10FT associated with 3m (10ft) throughout the order and receiving record.

Generic Compatibility and Factory Testing

Compatibility confirmation combines host identification with actual link establishment and diagnostic checks. The assembly is prepared for the stated OEM reference rather than selected only by connector shape. For a new data-center deployment, the equipment model, port mode and software release provide the most useful basis for a pre-order review. Where supported by the host, link stability and diagnostic indications are reviewed together with the established link.

Frequently Asked Questions

Is this an original equipment manufacturer cable?

No. It is manufactured by HT under our own manufacturer identity.

Are separate transceivers or patch leads required?

No. This is one complete direct-attach assembly. The ends are not detachable modules and should not be separated from the cable.

Can excess cable be folded into a compact bundle?

No. Use a supported, bend-safe service loop and observe the listed minimum bend radius. Do not crease the cable or tighten ties around the connector boots.

Will any matching connector operate at the same speed?

Not necessarily. Both hosts must support the stated rate, identification, lane mapping and any required breakout configuration; mechanical compatibility alone is insufficient.

Shipping and Lead Time

Standard configurations normally ship within one to three working days, while production quantities are confirmed with the order. Delivery can be arranged by courier, air freight or sea freight, and goods may instead be handed to an appointed forwarder or shipped on the customer’s courier account.


Featured Products


UAE Fiber Optics

UAE office: Abu Dhabi,Al khaleej Al Arabi
Factory add: ZYT industrial area, Shiyan, Baoan district, Shenzhen, China 518000

Popular Products

  • Fiber Optic Patch Cord
  • Fiber Optic Pigtail
  • Fiber Optic Attenuator
  • Fiber Optic Patch Panel
  • Fiber Optic Adapter

Products Datasheet

PDF catalogues of our products to download or for general inquiry, please send an email to sales@huihongfiber.com for details.

Customer Support

For customer support, please leave email to sales@huihongfiber.com, we shall reply to you as soon as possible.