
For data-center links that specify Generic QSFP-DD to QSFP-DD-400G-AEC-5M16FT, this 5m (16ft) AEC assembly delivers 400G connectivity through QSFP-DD to QSFP-DD. It removes separate module-and-patch-cord interfaces while retaining clear mechanical, power and compatibility details for high-density design and installation planning.
OEM Part Number: QSFP-DD to QSFP-DD-400G-AEC-5M16FTHT Part Number: QSFP-DD to QSFP-DD-400G-AEC-5M16FT
| HT Part Number | QSFP-DD to QSFP-DD-400G-AEC-5M16FT |
|---|---|
| Manufacturer | HT |
| Form Factor | QSFP-DD to QSFP-DD |
| Max. Data Rate | 400Gbps |
| Media | Copper |
| Cable Type | Active DAC (AEC) |
| Minimum Bend Radius | 53mm |
| Wire AWG | 28AWG |
| Cable Length | 5m (16ft) |
| Jacket Material | PET |
| Max. Power Consumption | 10W Per End |
| Modulation Format | 8x 50G-PAM4 |
| DDM/DOM | Supported |
| Commercial Temperature Range | 0 to 70°C (32 to 158°F) |
| Protocols | QSFP-DD MSA, IEEE 802.3cd, CMIS 5.0 |
The listed modulation format is 8x 50G-PAM4. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.
Select the assembly by both reach and rack layout. A direct connection removes separate module-and-patch-cord interfaces, but it still needs a bend-safe pathway and clear connector access. Keep cable bundles from blocking front-panel airflow, account for the listed interface power where applicable and choose a length that supports maintenance without leaving an unmanaged coil. For this assembly, the listed conductor specification is 28AWG; the minimum bend radius is 53mm; the stated power consumption is 10W Per End; the jacket material is PET.
The rated power consumption is 10W Per End. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.
This assembly uses 28AWG conductors, PET jacket, minimum bend radius 53mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.
The intended application is determined by the host interface and protocol support. Listed interface and protocol references include QSFP-DD MSA, IEEE 802.3cd, CMIS 5.0. Confirm that the host firmware and port configuration support the same operating mode.
The 5m (16ft) length gives QSFP-DD to QSFP-DD-400G-AEC-5M16FT more freedom for adjacent-rack and row-end deployments. Longer copper runs need particular attention to routing weight and bend control; the AEC specification and host support must still match the intended link.
QSFP-DD to QSFP-DD-400G-AEC-5M16FT is the longest of 4 verified length options in this family. Compared with QSFP-DD to QSFP-DD-400G-AEC-3M10FT at 3m (10ft), it provides 2m of additional reach for a longer vertical drop, a wider rack or an adjacent-cabinet route. Confirm that the complete path requires this length, because unused slack still needs supported, bend-safe storage.
Each cable receives connector inspection and a functional link check before it is coiled with bend-safe slack and packed. Protective materials shield the connector housings during transport. Rack or project labels are available to keep length, part number and installation destination aligned. Neutral packaging and customer-specific packing documentation are available on request.
Provide the OEM reference, HT part number, fixed length and quantity, together with the intended host interfaces. Rack-based quantities and packaging instructions can be included for larger deployments. Other lengths are separate products and should be entered on their own order lines. Quantity and any labeling instructions should be attached specifically to QSFP-DD to QSFP-DD-400G-AEC-5M16FT.
Compatibility confirmation combines host identification with actual link establishment and diagnostic checks. The assembly is prepared for the stated OEM reference rather than selected only by connector shape. For a new data-center deployment, the equipment model, port mode and software release provide the most useful basis for a pre-order review. Where supported by the host, link stability and diagnostic indications are reviewed together with the established link.
No. It is manufactured by HT under our own manufacturer identity.
No. This is one complete direct-attach assembly. The ends are not detachable modules and should not be separated from the cable.
No. Use a supported, bend-safe service loop and observe the listed minimum bend radius. Do not crease the cable or tighten ties around the connector boots.
Not necessarily. Both hosts must support the stated rate, identification, lane mapping and any required breakout configuration; mechanical compatibility alone is insufficient.
Standard configurations normally ship within one to three working days, while production quantities are confirmed with the order. Delivery can be arranged by courier, air freight or sea freight, and goods may instead be handed to an appointed forwarder or shipped on the customer’s courier account.
800G TransceiversOSFP and QSFP-DD modules for AI data center networks
400G QSFP-DDSR8, DR4, FR4 and LR4 modules and cables
100G QSFP28SR4, CWDM4, LR4 and ER4 transceivers
DAC CablesDirect attach copper cables from 10G up to 800G
AOC CablesActive optical cables for rack-to-rack links
MTP/MPO Trunk Cables8F to 144F multi fiber trunk and harness cables
Fiber Patch CablesOS2, OM3, OM4, OM5 jumpers with LC, SC, FC, ST connectors
Armored Patch CablesStainless steel tube protected fiber patch cords
UAE office: Abu Dhabi,Al khaleej Al Arabi
Factory add: ZYT industrial area, Shiyan, Baoan district, Shenzhen, China 518000