QSFP28 to 4 duplex LC-100G-AOC-70M230FT 100G QSFP28 4 x 25G NRZ to 4 Duplex LC 25G NRZ Active Optical Breakout Cable, 70m (230ft)

QSFP28 to 4 duplex LC-100G-AOC-70M230FT 100G QSFP28 4 x 25G NRZ to 4 Duplex LC 25G NRZ Active Optical Breakout Cable, 70m (230ft)

The product on this page is the 70m (230ft) version of Generic QSFP28 to 4 duplex LC-100G-AOC-70M230FT, built for 100G operation with QSFP28 to 4 duplex LC. Its complete AOC construction simplifies the physical link, and the sections below cover the exact specification, rack-integration considerations and factory verification for this individual order code.

OEM Part Number: QSFP28 to 4 duplex LC-100G-AOC-70M230FTHT Part Number: QSFP28 to 4 duplex LC-100G-AOC-70M230FT

Product Highlights

  • HT-manufactured AOC assembly in 70m (230ft)
  • 100G connectivity at 100Gbps
  • Interface configuration: QSFP28 to 4 duplex LC
  • Fixed length and part number: 70m (230ft), QSFP28 to 4 duplex LC-100G-AOC-70M230FT
  • Cable construction: Breakout AOC
  • Maximum power consumption: 2.2W
  • Minimum bend radius: 20mm
  • Operating temperature: 0 to 70°C (32 to 158°F)

Specifications

HT Part NumberQSFP28 to 4 duplex LC-100G-AOC-70M230FT
ManufacturerHT
Form FactorQSFP28 to 4 duplex LC
Max. Data Rate100Gbps
Cable Length70m (230ft)
Cable TypeBreakout AOC
Wavelength850nm
Minimum Bend Radius20mm
Transmitter TypeVCSEL
Receiver TypePIN
Max. Power Consumption2.2W
Modulation FormatQSFP28-4x 25G-NRZ Duplex LC-1x 25G-NRZ
CDR (Clock and Data Recovery)TX & RX Built-in CDR
Jacket MaterialOFNP
DDM/DOMSupported
Commercial Temperature Range0 to 70°C (32 to 158°F)
ProtocolsSFF-8436, SFF-8431

Signal and Lane Configuration

The listed modulation format is QSFP28-4x 25G-NRZ Duplex LC-1x 25G-NRZ. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.

Cable Construction and Routing

This assembly uses OFNP jacket, minimum bend radius 20mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.

Network and Protocol Considerations

The intended application is determined by the host interface and protocol support. Listed interface and protocol references include SFF-8436, SFF-8431. Confirm that the host firmware and port configuration support the same operating mode.

Breakout Port Mapping

The QSFP28 to 4 duplex LC configuration divides the high-speed interface into multiple lower-speed connections. Verify the upstream lane assignment, downstream port speeds and breakout setting on the host before connecting the assembly. Each branch must attach to the correct remote interface.

Integrated Optical Assembly

The optical engines and fiber are permanently integrated into this AOC. There are no detachable optical modules to clean or exchange. Handle the complete assembly by its connector housings and cable, and keep both ends matched to the same interface specification.

Length Selection and Installation Planning

Longer assemblies require disciplined cable dressing. For QSFP28 to 4 duplex LC-100G-AOC-70M230FT at 70m (230ft), use the intended managers rather than a diagonal route across the rack, and leave enough space to release each connector. Any service allowance should be loose and supported, with the integrated optical cable and both optical engines protected throughout the path. The next shorter verified assembly is QSFP28 to 4 duplex LC-100G-AOC-50M164FT at 50m (164ft), which is the better comparison when the managed route leaves substantial unused cable.

Position Within the Length Range

QSFP28 to 4 duplex LC-100G-AOC-70M230FT is the longest of 11 verified length options in this family. Compared with QSFP28 to 4 duplex LC-100G-AOC-50M164FT at 50m (164ft), it provides 20m of additional reach for a longer vertical drop, a wider rack or an adjacent-cabinet route. Confirm that the complete path requires this length, because unused slack still needs supported, bend-safe storage.

Data-Center Design and Airflow

Select the assembly by both reach and rack layout. A direct connection removes separate module-and-patch-cord interfaces, but it still needs a bend-safe pathway and clear connector access. Keep cable bundles from blocking front-panel airflow, account for the listed interface power where applicable and choose a length that supports maintenance without leaving an unmanaged coil. For this assembly, the minimum bend radius is 20mm; the stated power consumption is 2.2W; the jacket material is OFNP.

Power and Thermal Planning

The rated power consumption is 2.2W. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.

Quality Assurance and Packaging

Each cable receives connector inspection and a functional link check before it is coiled with bend-safe slack and packed. Protective materials shield the connector housings during transport. Rack or project labels are available to keep length, part number and installation destination aligned. Volume orders can include customer references on the labels and carton list.

Ordering Information

Provide the OEM reference, HT part number, fixed length and quantity, together with the intended host interfaces. Rack-based quantities and packaging instructions can be included for larger deployments. Other lengths are separate products and should be entered on their own order lines. This page’s fixed configuration is 70m (230ft); another length must be quoted under its corresponding part number.

Generic Compatibility and Factory Testing

Compatibility confirmation combines host identification with actual link establishment and diagnostic checks. The assembly is prepared for the stated OEM reference rather than selected only by connector shape. For a new data-center deployment, the equipment model, port mode and software release provide the most useful basis for a pre-order review. The check includes receive activity and diagnostic indications, followed by a final inspection of both ends.

Frequently Asked Questions

Is this an original equipment manufacturer cable?

No. It is manufactured by HT under our own manufacturer identity.

Can excess cable be folded into a compact bundle?

No. Use a supported, bend-safe service loop and observe the listed minimum bend radius. Do not crease the cable or tighten ties around the connector boots.

Will any matching connector operate at the same speed?

Not necessarily. Both hosts must support the stated rate, identification, lane mapping and any required breakout configuration; mechanical compatibility alone is insufficient.

What details assist a compatibility review?

Provide the equipment manufacturer, model, port type, hardware revision and software release, together with the OEM reference, required length and quantity.

Shipping and Lead Time

Standard configurations normally ship within one to three working days, while production quantities are confirmed with the order. International express, air cargo and sea freight can be selected according to destination and carton volume; customer courier accounts and nominated forwarders are also accepted.


Featured Products


UAE Fiber Optics

UAE office: Abu Dhabi,Al khaleej Al Arabi
Factory add: ZYT industrial area, Shiyan, Baoan district, Shenzhen, China 518000

Popular Products

  • Fiber Optic Patch Cord
  • Fiber Optic Pigtail
  • Fiber Optic Attenuator
  • Fiber Optic Patch Panel
  • Fiber Optic Adapter

Products Datasheet

PDF catalogues of our products to download or for general inquiry, please send an email to sales@huihongfiber.com for details.

Customer Support

For customer support, please leave email to sales@huihongfiber.com, we shall reply to you as soon as possible.