
This QSFP28 to 4 duplex LC-100G-AOC-7M23FT compatible AOC cable provides a 100G direct connection for Generic equipment in a fixed 7m (23ft) configuration. The QSFP28 to 4 duplex LC assembly integrates both ends and the cable, giving data-center designers one defined product to evaluate for reach, rack layout, airflow and host compatibility.
OEM Part Number: QSFP28 to 4 duplex LC-100G-AOC-7M23FTHT Part Number: QSFP28 to 4 duplex LC-100G-AOC-7M23FT
| HT Part Number | QSFP28 to 4 duplex LC-100G-AOC-7M23FT |
|---|---|
| Manufacturer | HT |
| Form Factor | QSFP28 to 4 duplex LC |
| Max. Data Rate | 100Gbps |
| Cable Length | 7m (23ft) |
| Cable Type | Breakout AOC |
| Wavelength | 850nm |
| Minimum Bend Radius | 20mm |
| Transmitter Type | VCSEL |
| Receiver Type | PIN |
| Max. Power Consumption | 2.2W |
| Modulation Format | QSFP28-4x 25G-NRZ Duplex LC-1x 25G-NRZ |
| CDR (Clock and Data Recovery) | TX & RX Built-in CDR |
| Jacket Material | OFNP |
| DDM/DOM | Supported |
| Commercial Temperature Range | 0 to 70°C (32 to 158°F) |
| Protocols | SFF-8436, SFF-8431 |
The listed modulation format is QSFP28-4x 25G-NRZ Duplex LC-1x 25G-NRZ. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.
Select the assembly by both reach and rack layout. A direct connection removes separate module-and-patch-cord interfaces, but it still needs a bend-safe pathway and clear connector access. Keep cable bundles from blocking front-panel airflow, account for the listed interface power where applicable and choose a length that supports maintenance without leaving an unmanaged coil. For this assembly, the minimum bend radius is 20mm; the stated power consumption is 2.2W; the jacket material is OFNP.
The rated power consumption is 2.2W. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.
This assembly uses OFNP jacket, minimum bend radius 20mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.
The intended application is determined by the host interface and protocol support. Listed interface and protocol references include SFF-8436, SFF-8431. Confirm that the host firmware and port configuration support the same operating mode.
The QSFP28 to 4 duplex LC configuration divides the high-speed interface into multiple lower-speed connections. Verify the upstream lane assignment, downstream port speeds and breakout setting on the host before connecting the assembly. Each branch must attach to the correct remote interface.
The optical engines and fiber are permanently integrated into this AOC. There are no detachable optical modules to clean or exchange. Handle the complete assembly by its connector housings and cable, and keep both ends matched to the same interface specification.
Choose QSFP28 to 4 duplex LC-100G-AOC-7M23FT when the measured managed path justifies 7m (23ft), not simply to leave a large spare coil. Additional reach can simplify adjacent-rack routing, yet unused cable still needs bend-safe storage and ventilation clearance. Keep identification visible so this extended version is not confused with shorter spares. Within this family, QSFP28 to 4 duplex LC-100G-AOC-5M16FT is shorter at 5m (16ft), while QSFP28 to 4 duplex LC-100G-AOC-10M33FT is the next longer choice at 10m (33ft); comparing those two boundaries helps avoid both tension and unnecessary slack.
QSFP28 to 4 duplex LC-100G-AOC-7M23FT occupies the middle of this family between QSFP28 to 4 duplex LC-100G-AOC-5M16FT at 5m (16ft) and QSFP28 to 4 duplex LC-100G-AOC-10M33FT at 10m (33ft). It adds 2m over the shorter option for extra routing clearance, while the next longer version adds another 3m. Measure the managed path and choose this version when its reach is sufficient without creating the slack associated with the longer assembly.
Each cable receives connector inspection and a functional link check before it is coiled with bend-safe slack and packed. Protective materials shield the connector housings during transport. Rack or project labels are available to keep length, part number and installation destination aligned. Standard protective packing is used by default, with project documentation arranged when requested.
Provide the OEM reference, HT part number, fixed length and quantity, together with the intended host interfaces. Rack-based quantities and packaging instructions can be included for larger deployments. Other lengths are separate products and should be entered on their own order lines. Quantity and any labeling instructions should be attached specifically to QSFP28 to 4 duplex LC-100G-AOC-7M23FT.
Compatibility confirmation combines host identification with actual link establishment and diagnostic checks. The assembly is prepared for the stated OEM reference rather than selected only by connector shape. For a new data-center deployment, the equipment model, port mode and software release provide the most useful basis for a pre-order review. Where supported by the host, receive activity and diagnostic indications are reviewed together with the established link.
No. It is manufactured by HT under our own manufacturer identity.
Only where both hosts explicitly support the complete interface and compatibility arrangement. Document each end and select the appropriate brand-specific product when required.
No. QSFP28 to 4 duplex LC-100G-AOC-7M23FT refers here to 7m (23ft). Every other verified length has a separate part number and page in the length list.
No. This is one complete direct-attach assembly. The ends are not detachable modules and should not be separated from the cable.
Standard configurations normally ship within one to three working days, while production quantities are confirmed with the order. International express, air cargo and sea freight can be selected according to destination and carton volume; customer courier accounts and nominated forwarders are also accepted.
800G TransceiversOSFP and QSFP-DD modules for AI data center networks
400G QSFP-DDSR8, DR4, FR4 and LR4 modules and cables
100G QSFP28SR4, CWDM4, LR4 and ER4 transceivers
DAC CablesDirect attach copper cables from 10G up to 800G
AOC CablesActive optical cables for rack-to-rack links
MTP/MPO Trunk Cables8F to 144F multi fiber trunk and harness cables
Fiber Patch CablesOS2, OM3, OM4, OM5 jumpers with LC, SC, FC, ST connectors
Armored Patch CablesStainless steel tube protected fiber patch cords
UAE office: Abu Dhabi,Al khaleej Al Arabi
Factory add: ZYT industrial area, Shiyan, Baoan district, Shenzhen, China 518000