QSFP28 to 4x SFP28-100G-AOC-20M66FT 100G QSFP28 4 x 25G NRZ to 4 x 25G SFP28 NRZ Active Optical Breakout Cable, 20m (66ft)

QSFP28 to 4x SFP28-100G-AOC-20M66FT 100G QSFP28 4 x 25G NRZ to 4 x 25G SFP28 NRZ Active Optical Breakout Cable, 20m (66ft)

This QSFP28 to 4x SFP28-100G-AOC-20M66FT compatible AOC cable provides a 100G direct connection for Generic equipment in a fixed 20m (66ft) configuration. The QSFP28 to 4x SFP28 assembly integrates both ends and the cable, giving data-center designers one defined product to evaluate for reach, rack layout, airflow and host compatibility.

OEM Part Number: QSFP28 to 4x SFP28-100G-AOC-20M66FTHT Part Number: QSFP28 to 4x SFP28-100G-AOC-20M66FT

Product Highlights

  • HT-manufactured AOC assembly in 20m (66ft)
  • 100G connectivity at 100Gbps
  • Interface configuration: QSFP28 to 4x SFP28
  • Fixed length and part number: 20m (66ft), QSFP28 to 4x SFP28-100G-AOC-20M66FT
  • Cable construction: Breakout AOC
  • Maximum power consumption: 2.2W (QSFP28 End)0.8W (SFP28 Per End)
  • Minimum bend radius: 30mm
  • Operating temperature: 0 to 70°C (32 to 158°F)

Specifications

HT Part NumberQSFP28 to 4x SFP28-100G-AOC-20M66FT
ManufacturerHT
Form FactorQSFP28 to 4x SFP28
Max. Data Rate100Gbps
Cable Length20m (66ft)
Cable TypeBreakout AOC
Wavelength850nm
Minimum Bend Radius30mm
Transmitter TypeVCSEL
Receiver TypePIN
Max. Power Consumption2.2W (QSFP28 End)0.8W (SFP28 Per End)
Modulation FormatQSFP28-4x 25G-NRZ SFP28-1x 25G-NRZ
CDR (Clock and Data Recovery)TX & RX Built-in CDR
Jacket MaterialOFNP
DDM/DOMSupported
Commercial Temperature Range0 to 70°C (32 to 158°F)
ProtocolsQSFP28 MSA, SFP28 MSA

Signal and Lane Configuration

The listed modulation format is QSFP28-4x 25G-NRZ SFP28-1x 25G-NRZ. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.

Integrated Optical Assembly

The optical engines and fiber are permanently integrated into this AOC. There are no detachable optical modules to clean or exchange. Handle the complete assembly by its connector housings and cable, and keep both ends matched to the same interface specification.

Length Selection and Installation Planning

Measure twice before deploying this 20m (66ft) cable: once along the planned route and again after accounting for service access. The objective is adequate reach without a concealed surplus. Support the integrated optical cable and both optical engines, preserve front-panel clearance and check that nearby power cords or sharp hardware cannot damage the jacket. Within this family, QSFP28 to 4x SFP28-100G-AOC-15M49FT is shorter at 15m (49ft), while QSFP28 to 4x SFP28-100G-AOC-25M82FT is the next longer choice at 25m (82ft); comparing those two boundaries helps avoid both tension and unnecessary slack.

Position Within the Length Range

QSFP28 to 4x SFP28-100G-AOC-20M66FT occupies the middle of this family between QSFP28 to 4x SFP28-100G-AOC-15M49FT at 15m (49ft) and QSFP28 to 4x SFP28-100G-AOC-25M82FT at 25m (82ft). It adds 5m over the shorter option for extra routing clearance, while the next longer version adds another 5m. Measure the managed path and choose this version when its reach is sufficient without creating the slack associated with the longer assembly.

Data-Center Design and Airflow

Select the assembly by both reach and rack layout. A direct connection removes separate module-and-patch-cord interfaces, but it still needs a bend-safe pathway and clear connector access. Keep cable bundles from blocking front-panel airflow, account for the listed interface power where applicable and choose a length that supports maintenance without leaving an unmanaged coil. For this assembly, the minimum bend radius is 30mm; the stated power consumption is 2.2W (QSFP28 End)0.8W (SFP28 Per End); the jacket material is OFNP.

Power and Thermal Planning

The rated power consumption is 2.2W (QSFP28 End)0.8W (SFP28 Per End). Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.

Cable Construction and Routing

This assembly uses OFNP jacket, minimum bend radius 30mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.

Network and Protocol Considerations

The intended application is determined by the host interface and protocol support. Listed interface and protocol references include QSFP28 MSA, SFP28 MSA. Confirm that the host firmware and port configuration support the same operating mode.

Breakout Port Mapping

The QSFP28 to 4x SFP28 configuration divides the high-speed interface into multiple lower-speed connections. Verify the upstream lane assignment, downstream port speeds and breakout setting on the host before connecting the assembly. Each branch must attach to the correct remote interface.

Quality Assurance and Packaging

Each cable receives connector inspection and a functional link check before it is coiled with bend-safe slack and packed. Protective materials shield the connector housings during transport. Rack or project labels are available to keep length, part number and installation destination aligned. Volume orders can include customer references on the labels and carton list.

Ordering Information

Provide the OEM reference, HT part number, fixed length and quantity, together with the intended host interfaces. Rack-based quantities and packaging instructions can be included for larger deployments. Other lengths are separate products and should be entered on their own order lines. Quantity and any labeling instructions should be attached specifically to QSFP28 to 4x SFP28-100G-AOC-20M66FT.

Generic Compatibility and Factory Testing

Compatibility confirmation combines host identification with actual link establishment and diagnostic checks. The assembly is prepared for the stated OEM reference rather than selected only by connector shape. For a new data-center deployment, the equipment model, port mode and software release provide the most useful basis for a pre-order review. The check includes receive activity and diagnostic indications, followed by a final inspection of both ends.

Frequently Asked Questions

Is this an original equipment manufacturer cable?

No. It is manufactured by HT under our own manufacturer identity.

Can different brands be connected with the same assembly?

Only where both hosts explicitly support the complete interface and compatibility arrangement. Document each end and select the appropriate brand-specific product when required.

Does this order code cover multiple lengths?

No. QSFP28 to 4x SFP28-100G-AOC-20M66FT refers here to 20m (66ft). Every other verified length has a separate part number and page in the length list.

Are separate transceivers or patch leads required?

No. This is one complete direct-attach assembly. The ends are not detachable modules and should not be separated from the cable.

Shipping and Lead Time

Available stock is generally dispatched within one to three working days after order confirmation, with production lead times advised for larger quantities. Delivery can be arranged by courier, air freight or sea freight, and goods may instead be handed to an appointed forwarder or shipped on the customer’s courier account.


Featured Products


UAE Fiber Optics

UAE office: Abu Dhabi,Al khaleej Al Arabi
Factory add: ZYT industrial area, Shiyan, Baoan district, Shenzhen, China 518000

Popular Products

  • Fiber Optic Patch Cord
  • Fiber Optic Pigtail
  • Fiber Optic Attenuator
  • Fiber Optic Patch Panel
  • Fiber Optic Adapter

Products Datasheet

PDF catalogues of our products to download or for general inquiry, please send an email to sales@huihongfiber.com for details.

Customer Support

For customer support, please leave email to sales@huihongfiber.com, we shall reply to you as soon as possible.