QSFP56 to 2x QSFP56-200G-ACC-7M23FT 200G QSFP56 4 x 50G PAM4 to 2 x 100G QSFP56 2 x 50G PAM4 Active Copper Breakout Cable, 7m (23ft)

QSFP56 to 2x QSFP56-200G-ACC-7M23FT 200G QSFP56 4 x 50G PAM4 to 2 x 100G QSFP56 2 x 50G PAM4 Active Copper Breakout Cable, 7m (23ft)

The product on this page is the 7m (23ft) version of Generic QSFP56 to 2x QSFP56-200G-ACC-7M23FT, built for 200G operation with QSFP56 to 2x QSFP56. Its complete ACC construction simplifies the physical link, and the sections below cover the exact specification, rack-integration considerations and factory verification for this individual order code.

OEM Part Number: QSFP56 to 2x QSFP56-200G-ACC-7M23FTHT Part Number: QSFP56 to 2x QSFP56-200G-ACC-7M23FT

Product Highlights

  • HT-manufactured ACC assembly in 7m (23ft)
  • 200G connectivity at 200Gbps
  • Interface configuration: QSFP56 to 2x QSFP56
  • Fixed length and part number: 7m (23ft), QSFP56 to 2x QSFP56-200G-ACC-7M23FT
  • Cable construction: Active Twinax
  • Conductor specification: 26AWG
  • Maximum power consumption: ≤1.5W
  • Minimum bend radius: 36.5mm

Specifications

HT Part NumberQSFP56 to 2x QSFP56-200G-ACC-7M23FT
ManufacturerHT
Form FactorQSFP56 to 2x QSFP56
Max Data Rate200Gbps
Cable Length7m (23ft)
Wire AWG26AWG
Minimum Bend Radius36.5mm
Power Consumption≤1.5W
Cable TypeActive Twinax
Jacket MaterialPVC (OFNR)
Commercial Temperature Range0 to 70°C (32 to 158°F)
ProtocolsIEEE 802.3cd, SFF-8665, QSFP MSA, SFF-8679, SFF-8636

Power and Thermal Planning

The rated power consumption is ≤1.5W. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.

Breakout Port Mapping

The QSFP56 to 2x QSFP56 configuration divides the high-speed interface into multiple lower-speed connections. Verify the upstream lane assignment, downstream port speeds and breakout setting on the host before connecting the assembly. Each branch must attach to the correct remote interface.

Length Selection and Installation Planning

The installation review for a 7m (23ft) link should include pathway length, support points, connector access and future maintenance. Route the complete copper assembly and both connector housings before attaching both ends, and avoid dragging it across connector panels. A final inspection should confirm that no latch, boot or jacket section carries unnecessary strain. The next shorter verified assembly is QSFP56 to 2x QSFP56-200G-ACC-5M16FT at 5m (16ft), which is the better comparison when the managed route leaves substantial unused cable.

Position Within the Length Range

QSFP56 to 2x QSFP56-200G-ACC-7M23FT is the longest of 3 verified length options in this family. Compared with QSFP56 to 2x QSFP56-200G-ACC-5M16FT at 5m (16ft), it provides 2m of additional reach for a longer vertical drop, a wider rack or an adjacent-cabinet route. Confirm that the complete path requires this length, because unused slack still needs supported, bend-safe storage.

Data-Center Design and Airflow

Select the assembly by both reach and rack layout. A direct connection removes separate module-and-patch-cord interfaces, but it still needs a bend-safe pathway and clear connector access. Keep cable bundles from blocking front-panel airflow, account for the listed interface power where applicable and choose a length that supports maintenance without leaving an unmanaged coil. For this assembly, the listed conductor specification is 26AWG; the minimum bend radius is 36.5mm; the stated power consumption is ≤1.5W; the jacket material is PVC (OFNR).

Cable Construction and Routing

This assembly uses 26AWG conductors, PVC (OFNR) jacket, minimum bend radius 36.5mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.

Network and Protocol Considerations

The intended application is determined by the host interface and protocol support. Listed interface and protocol references include IEEE 802.3cd, SFF-8665, QSFP MSA, SFF-8679, SFF-8636. Confirm that the host firmware and port configuration support the same operating mode.

Quality Assurance and Packaging

Each cable receives connector inspection and a functional link check before it is coiled with bend-safe slack and packed. Protective materials shield the connector housings during transport. Rack or project labels are available to keep length, part number and installation destination aligned. Standard protective packing is used by default, with project documentation arranged when requested.

Ordering Information

Provide the OEM reference, HT part number, fixed length and quantity, together with the intended host interfaces. Rack-based quantities and packaging instructions can be included for larger deployments. Other lengths are separate products and should be entered on their own order lines. Keep QSFP56 to 2x QSFP56-200G-ACC-7M23FT associated with 7m (23ft) throughout the order and receiving record.

Generic Compatibility and Factory Testing

Compatibility confirmation combines host identification with actual link establishment and diagnostic checks. The assembly is prepared for the stated OEM reference rather than selected only by connector shape. For a new data-center deployment, the equipment model, port mode and software release provide the most useful basis for a pre-order review. The check includes link stability and diagnostic indications, followed by a final inspection of both ends.

Frequently Asked Questions

Is this an original equipment manufacturer cable?

No. It is manufactured by HT under our own manufacturer identity.

Does this order code cover multiple lengths?

No. QSFP56 to 2x QSFP56-200G-ACC-7M23FT refers here to 7m (23ft). Every other verified length has a separate part number and page in the length list.

Are separate transceivers or patch leads required?

No. This is one complete direct-attach assembly. The ends are not detachable modules and should not be separated from the cable.

Can excess cable be folded into a compact bundle?

No. Use a supported, bend-safe service loop and observe the listed minimum bend radius. Do not crease the cable or tighten ties around the connector boots.

Shipping and Lead Time

Available stock is generally dispatched within one to three working days after order confirmation, with production lead times advised for larger quantities. Delivery can be arranged by courier, air freight or sea freight, and goods may instead be handed to an appointed forwarder or shipped on the customer’s courier account.


Featured Products


UAE Fiber Optics

UAE office: Abu Dhabi,Al khaleej Al Arabi
Factory add: ZYT industrial area, Shiyan, Baoan district, Shenzhen, China 518000

Popular Products

  • Fiber Optic Patch Cord
  • Fiber Optic Pigtail
  • Fiber Optic Attenuator
  • Fiber Optic Patch Panel
  • Fiber Optic Adapter

Products Datasheet

PDF catalogues of our products to download or for general inquiry, please send an email to sales@huihongfiber.com for details.

Customer Support

For customer support, please leave email to sales@huihongfiber.com, we shall reply to you as soon as possible.