SC UPC to Unterminated Fiber Pigtail, Simplex, OS2, 0.9mm

SC UPC to Unterminated Fiber Pigtail, Simplex, OS2, 0.9mm

For UAE project teams, the key is to match this exact configuration to the port schedule, optical budget and delivery documentation. This fiber pigtail terminates outside-plant or backbone cable into a connectorized panel: SC UPC to Unterminated Fiber Pigtail, OS2 glass, with a factory-polished SC UPC connector on one end and a prepared fiber strand on the other. Fusion-spliced onto the incoming cable, it turns a raw fiber path into a documented, testable port.

Product Highlights

  • G.657.A1 Bend Insensitive Fiber & 10mm Min. Bend Radius
  • Precision Zirconia Ferrule Connectors Ensure Low Loss
  • Easy-strip 900µm Tight-buffered Coating
  • Color-Coded Cable Jacket for Easy Identification
  • Support Both Fusion and Mechanical Splicing

Specifications

Connector ASC UPC Simplex
Connector BUnterminated
Fiber Count1 Fiber
Fiber GradeG.657.A1
Fiber ModeOS2 9/125μm
Wavelength1310/1550nm
Jacket ColorYellow
Cable JacketPVC (Unrated)
Min. Bend Radius (Optical Fiber)10mm
Min. Bend Radius (Fiber Cable)10/5D (Dynamic/Static)
Connector Durability1000 Times
Attenuation at 1310nm0.36dB/km
Attenuation at 1550nm0.22dB/km
Insertion Loss≤0.3dB
Return Loss≥50dB
Operating Temperature-40 to 75°C (-40 to 167℉)
Storage Temperature-45 to 85°C (-49 to 185℉)
Connector TypeSC to Unterminated
Fiber Count1 Fiber
Fiber GradeG.657.A1

Why pigtails remain the standard termination

A pigtail is half an interface: one end is a factory-built connector, polished and tested under procedure control; the other is a bare fiber strand ready for the splice. Fusion-splicing that strand onto the existing cable brings this connector quality of the factory to a field path. The result outperforms field-polished connectors on insertion loss, return loss and long-term stability, and it outperforms pre-terminated trunks when the path length is uncertain or the pathway is difficult to pre-measure.

Fusion splicing practice that protects the budget

A good splice starts long before the splicer arcs: strip the strand cleanly, cleave square, keep the sleeve staged, and protect the completed splice in the tray with the bend radius respected. The tight-buffered 0.9mm coating on this pigtail strips in one motion and seats cleanly in standard splice sleeves. Done well, a fusion splice adds less attenuation than a connector pair and stays stable for the life of the plant. For UAE procurement, record this requirement with the project documents so the supplied configuration can be checked on arrival.

Mechanical splicing as the field fallback

Where a fusion splicer is not offered, mechanical splices get the connection up: the strand cleaves, seats in the mechanical splice body and locks against the field fiber. The loss is higher than a fusion joint and the reflectance worse, so the practice is a fallback rather than a standard - but for urgent restoration work a pigtail that supports the two methods keeps the choice open.

Choosing the fiber mode for the plant

Single-mode OS2 serves long links, PON access and any plant where distance or wavelength plans matter; the bend-insensitive glass grade keeps attenuation stable in dense trays. OM3 and OM4 multimode serve hardware rooms and data halls where transceiver cost favors short-reach optics. OM1 and OM2 remain in service in legacy plants and must be matched like-for-like. The pigtail mode must equal this cable plant mode - a mismatch splices poorly and performs worse.

Bend-insensitive glass in dense trays

Splice trays and panel rear spaces punish fiber: tight routing, crowded dressing and the occasional hurried re-entry all bend strands beyond what legacy single-mode tolerated. The bend-insensitive grade used in this pigtail holds attenuation stable at bend radii that would fog conventional glass, which keeps the connection margin intact after the tenth tray opening, not just at commissioning.

A splicing workflow that scales

Productive termination crews work to a fixed routine: mount the tray, dress this cable, splice the pigtails color by color, protect every joint, test every completed port, then close and label. With the routine fixed, a two-person crew terminates a full frame location in a predictable time, and the test record maps cleanly onto the documentation. The consistency additionally makes quality auditable - identical materials, identical sequence, identical pass criteria across each site.

Sparing and kit planning for termination work

Pigtails belong in the termination kit in counted sets with spares: strands break, connectors get contaminated beyond recovery, and a missing spare converts a ten-minute task into a second visit. Plan one spare set per frame location, keep spare strands capped and bagged, and record which set went into which tray so replacement stock may be ordered to the identical specification.

Selecting the right pigtail for the job

Five decisions define the order: this connector series must be matched to this panel, the polish must be matched to the plant, the fiber mode must be matched to this cable, the build must be matched to the path, and the count must be matched to the tray capacity. Getting all five right at order time is what turns a box of strands into a dependable termination. Where the need sits outside the standard configurations, the custom platforms cover the remaining combinations.

Quality Control and Testing

Each pigtail is optically tested before packing: insertion loss and return loss are verified on every terminated leg, and the ferrule end faces are inspected for scratches and contamination. The strands ship coiled, capped and bagged, with the test results offered on specify.

Ordering and Factory Support

Refer to this pigtail by connector, polish, fiber mode, fiber count and build when ordering a quotation. For configurations outside the listed options - mixed connector families, jacket ratings, lengths or project packing - send the need with the inquiry and the factory will verify the manufacturable specification. Our UAE project support can review the requirement with Shenzhen production before a formal quotation is issued.

 

Fiber Optic UAE supplies SC UPC to Unterminated Fiber Pigtail, Simplex, OS2, 0.9mm to data centers, ISPs and enterprises in Dubai, Abu Dhabi, Sharjah and across the Gulf region, with project support from our UAE office and production coordination from our Shenzhen factory.


UAE Fiber Optics

UAE office: Abu Dhabi,Al khaleej Al Arabi
Factory add: ZYT industrial area, Shiyan, Baoan district, Shenzhen, China 518000

Popular Products

  • Fiber Optic Patch Cord
  • Fiber Optic Pigtail
  • Fiber Optic Attenuator
  • Fiber Optic Patch Panel
  • Fiber Optic Adapter