The product on this page is the 1m (3ft) version of Generic SFP28 to SFP28-25G-ACC-1M3FT, built for 25G operation with SFP28 to SFP28. Its complete ACC construction simplifies the physical link, and the sections below cover the exact specification, rack-integration considerations and factory verification for this individual order code.
OEM Part Number: SFP28 to SFP28-25G-ACC-1M3FTHT Part Number: SFP28 to SFP28-25G-ACC-1M3FT
| HT Part Number | SFP28 to SFP28-25G-ACC-1M3FT |
|---|---|
| Manufacturer | HT |
| Form Factor | SFP28 to SFP28 |
| Max Data Rate | 25Gbps |
| Media | Copper |
| Cable Type | Active Twinax |
| Cable Length | 1m (3ft) |
| Wire AWG | 30AWG |
| Minimum Bend Radius | 22.5mm |
| Power Consumption | ≤0.55W |
| Jacket Material | PVC (OFNR) |
| Commercial Temperature Range | 0 to 70°C (32 to 158°F) |
| Protocols | IEEE 802.3, SFP28 MSA, SFF-8402 |
The rated power consumption is ≤0.55W. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.
This assembly uses 30AWG conductors, PVC (OFNR) jacket, minimum bend radius 22.5mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.
The intended application is determined by the host interface and protocol support. Listed interface and protocol references include IEEE 802.3, SFP28 MSA, SFF-8402. Confirm that the host firmware and port configuration support the same operating mode.
At 1m (3ft), SFP28 to SFP28-25G-ACC-1M3FT is a practical choice for direct connections within one rack. Route the cable along the intended management path rather than pulling it diagonally across adjacent connectors, and leave enough clearance for insertion, removal and front-panel airflow.
SFP28 to SFP28-25G-ACC-1M3FT is the shortest of 9 verified length options in this family. It is the preferred choice when the port positions are close and cable slack must be kept to a minimum. The next option is SFP28 to SFP28-25G-ACC-2M7FT at 2m (7ft), adding 1m for a less direct routing path; selecting it unnecessarily would leave more cable to dress.
Select the assembly by both reach and rack layout. A direct connection removes separate module-and-patch-cord interfaces, but it still needs a bend-safe pathway and clear connector access. Keep cable bundles from blocking front-panel airflow, account for the listed interface power where applicable and choose a length that supports maintenance without leaving an unmanaged coil. For this assembly, the listed conductor specification is 30AWG; the minimum bend radius is 22.5mm; the stated power consumption is ≤0.55W; the jacket material is PVC (OFNR).
Each cable receives connector inspection and a functional link check before it is coiled with bend-safe slack and packed. Protective materials shield the connector housings during transport. Rack or project labels are available to keep length, part number and installation destination aligned. Volume orders can include customer references on the labels and carton list.
Provide the OEM reference, HT part number, fixed length and quantity, together with the intended host interfaces. Rack-based quantities and packaging instructions can be included for larger deployments. Other lengths are separate products and should be entered on their own order lines. Quantity and any labeling instructions should be attached specifically to SFP28 to SFP28-25G-ACC-1M3FT.
Compatibility confirmation combines host identification with actual link establishment and diagnostic checks. The assembly is prepared for the stated OEM reference rather than selected only by connector shape. For a new data-center deployment, the equipment model, port mode and software release provide the most useful basis for a pre-order review. Both connectors are examined before the operating test, which includes link stability and diagnostic indications.
No. It is manufactured by HT under our own manufacturer identity.
No. SFP28 to SFP28-25G-ACC-1M3FT refers here to 1m (3ft). Every other verified length has a separate part number and page in the length list.
No. This is one complete direct-attach assembly. The ends are not detachable modules and should not be separated from the cable.
No. Use a supported, bend-safe service loop and observe the listed minimum bend radius. Do not crease the cable or tighten ties around the connector boots.
Standard configurations normally ship within one to three working days, while production quantities are confirmed with the order. Delivery can be arranged by courier, air freight or sea freight, and goods may instead be handed to an appointed forwarder or shipped on the customer’s courier account.
800G TransceiversOSFP and QSFP-DD modules for AI data center networks
400G QSFP-DDSR8, DR4, FR4 and LR4 modules and cables
100G QSFP28SR4, CWDM4, LR4 and ER4 transceivers
DAC CablesDirect attach copper cables from 10G up to 800G
AOC CablesActive optical cables for rack-to-rack links
MTP/MPO Trunk Cables8F to 144F multi fiber trunk and harness cables
Fiber Patch CablesOS2, OM3, OM4, OM5 jumpers with LC, SC, FC, ST connectors
Armored Patch CablesStainless steel tube protected fiber patch cords
UAE office: Abu Dhabi,Al khaleej Al Arabi
Factory add: ZYT industrial area, Shiyan, Baoan district, Shenzhen, China 518000