SN UPC 4 Channels (8F) OS2 Fiber Adapter without Flange

SN UPC 4 Channels (8F) OS2 Fiber Adapter without Flange

For UAE project teams, the key is to match this exact configuration to the port schedule, optical budget and delivery documentation. %s belongs to the very-small-form-factor generation of fiber connectivity. Compared with a duplex LC location, the VSFF interface carries the identical two fibers in roughly half this panel space, which is what makes 200G, 400G and 800G breakout panels physically possible at high port counts. This adapter holds the ferrules aligned and latches these connectors positively.

Product Highlights

  • ≤0.2dB (Typical) Low Insertion Loss
  • Mates SN Standard, Junior and Compact Connectors
  • Allows Up to 4 Times Higher Density Compared to Duplex LC Adapter
  • 4 Independent Duplex Fiber Breakout at a Quad-style QSFP, QSFP-DD & OSFP Transceiver
  • Color Coded for Rapid Identification of Single Mode Fiber Patterns

Specifications

Connector TypeSenko SN-SN
Body Style4-Port
Polish TypeUPC
Fiber ModeOS2 9/125μm
Insertion Loss≤0.2dB
Durability500 times
Mounting TypeReduced Flanged
ColorBlue
Flammability RateUL 94V-0
RoHS Compliancy StatusCompliant
Operating Temperature-40 to 85℃(-40 to 185℉)
Storage Temperature-10 to 60℃(14 to 140℉)
Compliance CenterTest Center

Phosphor bronze and zirconia sleeves compared

Two sleeve materials dominate this adapter market. Zirconia ceramic sleeves give the tightest alignment and are the proper option for single-mode and high-behavior multimode work, where core geometry leaves no room for eccentricity. Phosphor bronze sleeves serve legacy multimode and metallic-ferrule connectors where the tolerance need is looser and the cost matters more. Matching the sleeve to the application keeps the two behavior and budget under control.

Very small form factor connectivity

VSFF interfaces - CS, SN, MDC and MMC among them - exist because the duplex LC became the bottleneck of panel density. A CS or SN location carries two fibers in about half the LC duplex space, and an MMC carries sixteen in the space of a small module. The adapters that mount these interfaces hold the identical optical discipline as their larger ancestors: precision sleeves or guide-pin alignment, positive latching and keyed orientation. The reward is a panel that serves 400G and 800G breakout optics at full port count.

Planning a VSFF panel position

VSFF adapters belong wherever breakout optics meet the fiber plant: a 400G-DR4 transceiver breaks to four duplex positions, and at CS or SN density those four positions fit beside their neighbors without a larger chassis. Plan this panel around the transceiver roadmap - this adapter footprint follows this connector, and this connector follows the optics. Keeping spare VSFF adapters in the site kit is cheap insurance, because the format is new sufficient that local stockists rarely carry it.

What adapter testing actually measures

An adapter contributes no signal of its own, so its test is a mating test: reference connectors mate through this adapter, and the inserted loss is recorded. A zirconia-sleeve adapter ought to add no more than 0.2 dB, and the mating must repeat that figure across cycles. Durability testing runs the mating hundreds of times and re-measures - a sleeve that wears loose announces itself as creeping loss. These figures, not the housing color, are what separates an adapter that serves for years from one that becomes the mystery fault.

Selecting the right adapter for the panel

Five decisions define this adapter order: this connector pairing must be matched to the two sides of the mating, the mounting style must fit this panel cutout, the polish color code must be matched to the plant, the sleeve material must suit the behavior grade, and the count must cover the load-out plus spares. Getting all five right at order time is what turns a bag of couplers into a dependable panel. Where the pairing crosses connector families, the hybrid range covers the common conversions.

Quality Control and Testing

Each adapter is inspected before packing: the sleeve bore is checked for alignment and surface finish, the housing latches are cycled for positive engagement, and sample matings from every production lot are measured for insertion loss. Accessories are checked for fit against the adapters they serve.

Ordering and Factory Support

Refer to this adapter by connector pairing, mounting style, polish grade and pack unit count when ordering a quotation. For configurations outside the listed options - mixed packs, panel hardware kits or project packing - send the need with the inquiry and the factory will verify the manufacturable specification. Our UAE project support can review the requirement with Shenzhen production before a formal quotation is issued.

 

Fiber Optic UAE supplies SN UPC 4 Channels (8F) OS2 Fiber Adapter without Flange to data centers, ISPs and enterprises in Dubai, Abu Dhabi, Sharjah and across the Gulf region, with project support from our UAE office and production coordination from our Shenzhen factory.


UAE Fiber Optics

UAE office: Abu Dhabi,Al khaleej Al Arabi
Factory add: ZYT industrial area, Shiyan, Baoan district, Shenzhen, China 518000

Popular Products

  • Fiber Optic Patch Cord
  • Fiber Optic Pigtail
  • Fiber Optic Attenuator
  • Fiber Optic Patch Panel
  • Fiber Optic Adapter

Products Datasheet

PDF catalogues of our products to download or for general inquiry, please send an email to sales@huihongfiber.com for details.

Customer Support

For customer support, please leave email to sales@huihongfiber.com, we shall reply to you as soon as possible.