MMC-16 to MTP-16 APC Jumper, 16 Fibers, OM4
MMC-16 to MTP-16 APC Jumper, 16 Fibers, OM4

For UAE project teams, the key is to match this exact configuration to the port schedule, optical budget and delivery documentation. This MMC-16 to MTP-16 jumper connects two distinct multi-fiber form factors over sixteen OM4 fibers. The MMC side and MTP Elite end are the two APC female, and the bend-insensitive multimode cable uses a 2.5mm plenum jacket. It offers a direct, compact patching choice between MMC infrastructure and installed MTP-16 multimode hardware.

Product Highlights

  • MMC Female to MTP® Female, 16 Fibers
  • OM4 50/125μm, bend-insensitive fiber
  • MMC insertion loss ≤0.35dB, return loss ≥40/45dB (MMC/MTP®)
  • Jumper Polarity wiring scheme
  • 2.5mm Plenum (OFNP) cable
  • Standard length options: 1m (3ft), 2m (7ft), 3m (10ft)

Specifications

Part Number16FMMCMTPOM4
ManufacturerHT
Connector AUS Conec MMC Female (Non-Pinned)
Connector BUS Conec MTP® Elite Female (Non-Pinned)
Polish TypeAPC to APC
Glass FiberBend Insensitive Fiber
Fiber ModeOM4 50/125μm
Wavelength850/1300nm
Fiber Count16 Fibers
PolarityJumper Polarity
Cable Outside Diameter (OD)2.5mm
Cable JacketPlenum (OFNP)
Min. Bend Radius (Optical Fiber)7.5mm
Min. Bend Radius (Fiber Cable)20/10D (Dynamic/Static)
Tensile Strength (Long Term)30N
Tensile Strength (Short Term)100N
Insertion Loss≤0.35dB
Return Loss≥40/45dB (MMC/MTP®)
Attenuation at 850nm≤2.3dB/km
Attenuation at 1300nm≤0.6dB/km
Operating Temperature-10 to 60°C (14 to 140℉)
Storage Temperature-10 to 70°C (14 to 158℉)

Practical role in a multimode channel

This assembly suits migrations where MMC panels are being introduced without replacing each MTP-based interface. A single factory-built jumper avoids an extra adapter pair that would otherwise be needed to convert form factors. It remains essential to review that the active hardware or cassette presents the proper pinned mates and that the link requires APC at the two ends.

Connector-specific return-loss requirements

The MMC interface is specified for at least 40dB return loss, while the MTP APC interface is specified for at least 45dB; maximum insertion loss across this assembly is 0.35dB. Keeping distinct connector figures in the documentation makes fault finding more meaningful. OM4 attenuation is 2.3dB/km at 850nm and 0.6dB/km at 1300nm, with actual setup reach set by the optics.

Installation length and cable care

Select from 1m (3ft), 2m (7ft) and 3m (10ft) standard versions, or specify a customized meter or foot length. Do not pull this assembly by either connector boot during routing. Support the 2.5mm cable through the manager, keep the 7.5mm fiber bend allowance and keep dust caps fitted until the two end faces have been inspected.

Ordering and Factory Support

Order by part number 16FMMCMTPOM4 with length and unit count. Customized identifiers may specify the MMC and MTP ends individually, which is helpful when multiple transition patch cords occupy the identical panel; specify this identification when submitting the order. Our UAE project support can review the requirement with Shenzhen production before a formal quotation is issued.

 

Fiber Optic UAE supplies MMC-16 to MTP-16 APC Jumper, 16 Fibers, OM4 to data centers, ISPs and enterprises in Dubai, Abu Dhabi, Sharjah and across the Gulf region, with project support from our UAE office and production coordination from our Shenzhen factory.


UAE Fiber Optics

UAE office: Abu Dhabi,Al khaleej Al Arabi
Factory add: ZYT industrial area, Shiyan, Baoan district, Shenzhen, China 518000

Popular Products

  • Fiber Optic Patch Cord
  • Fiber Optic Pigtail
  • Fiber Optic Attenuator
  • Fiber Optic Patch Panel
  • Fiber Optic Adapter

Products Datasheet

PDF catalogues of our products to download or for general inquiry, please send an email to sales@huihongfiber.com for details.

Customer Support

For customer support, please leave email to sales@huihongfiber.com, we shall reply to you as soon as possible.