
The product on this page is the 1.5m (5ft) version of Generic OSFP (IHS/Finned Top) to 4x QSFP112-800G-DAC-1.5M5FT, built for 800G operation with OSFP (IHS/Finned Top) to 4x QSFP112. Its complete DAC construction simplifies the physical link, and the sections below cover the exact specification, rack-integration considerations and factory verification for this individual order code.
OEM Part Number: OSFP (IHS/Finned Top) to 4x QSFP112-800G-DAC-1.5M5FTHT Part Number: OSFP (IHS/Finned Top) to 4x QSFP112-800G-DAC-1.5M5FT
| HT Part Number | OSFP (IHS/Finned Top) to 4x QSFP112-800G-DAC-1.5M5FT |
|---|---|
| Manufacturer | HT |
| Form Factor | OSFP (IHS/Finned Top) to 4x QSFP112 |
| Max. Data Rate | 800Gbps |
| Media | Copper |
| Cable Type | Passive Breakout DAC |
| Cable Length | 1.5m (5ft) |
| Jacket Material | PVC |
| Minimum Bend Radius | 31mm |
| Wire AWG | 28AWG |
| Max. Power Consumption | 0.1W (OSFP End)0.1W (QSFP112 Per End) |
| Modulation Format | OSFP-8x 100G-PAM4QSFP112-2x 100G-PAM4 |
| Commercial Temperature Range | 0 to 70°C (32 to 158°F) |
| Application | 800G/200G Ethernet |
| Protocols | OSFP MSA, QSFP112 MSA, IEEE 802.3ck, CMIS v5.0 |
The listed modulation format is OSFP-8x 100G-PAM4QSFP112-2x 100G-PAM4. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.
Select the assembly by both reach and rack layout. A direct connection removes separate module-and-patch-cord interfaces, but it still needs a bend-safe pathway and clear connector access. Keep cable bundles from blocking front-panel airflow, account for the listed interface power where applicable and choose a length that supports maintenance without leaving an unmanaged coil. For this assembly, the listed conductor specification is 28AWG; the minimum bend radius is 31mm; the stated power consumption is 0.1W (OSFP End)0.1W (QSFP112 Per End); the jacket material is PVC.
The rated power consumption is 0.1W (OSFP End)0.1W (QSFP112 Per End). Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.
This assembly uses 28AWG conductors, PVC jacket, minimum bend radius 31mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.
The intended application is 800G/200G Ethernet. Listed interface and protocol references include OSFP MSA, QSFP112 MSA, IEEE 802.3ck, CMIS v5.0. Confirm that the host firmware and port configuration support the same operating mode.
The OSFP (IHS/Finned Top) to 4x QSFP112 configuration divides the high-speed interface into multiple lower-speed connections. Verify the upstream lane assignment, downstream port speeds and breakout setting on the host before connecting the assembly. Each branch must attach to the correct remote interface.
A passive DAC has no separate optical conversion stage. Its low-power, low-latency operation is useful for short equipment links, but the assembly must remain within the length and signaling mode accepted by both hosts.
The additional half metre beyond a one-metre assembly gives OSFP (IHS/Finned Top) to 4x QSFP112-800G-DAC-1.5M5FT useful routing flexibility when the ports are not directly aligned. It can accommodate a different rack unit or a short service loop, but excess cable should be dressed loosely rather than folded into a tight coil.
OSFP (IHS/Finned Top) to 4x QSFP112-800G-DAC-1.5M5FT occupies the middle of this family between OSFP (IHS/Finned Top) to 4x QSFP112-800G-DAC-1M3FT at 1m (3ft) and OSFP (IHS/Finned Top) to 4x QSFP112-800G-DAC-2M7FT at 2m (7ft). It adds 0.5m over the shorter option for extra routing clearance, while the next longer version adds another 0.5m. Measure the managed path and choose this version when its reach is sufficient without creating the slack associated with the longer assembly.
Each cable receives connector inspection and a functional link check before it is coiled with bend-safe slack and packed. Protective materials shield the connector housings during transport. Rack or project labels are available to keep length, part number and installation destination aligned. Volume orders can include customer references on the labels and carton list.
Provide the OEM reference, HT part number, fixed length and quantity, together with the intended host interfaces. Rack-based quantities and packaging instructions can be included for larger deployments. Other lengths are separate products and should be entered on their own order lines. Keep OSFP (IHS/Finned Top) to 4x QSFP112-800G-DAC-1.5M5FT associated with 1.5m (5ft) throughout the order and receiving record.
Compatibility confirmation combines host identification with actual link establishment and diagnostic checks. The assembly is prepared for the stated OEM reference rather than selected only by connector shape. For a new data-center deployment, the equipment model, port mode and software release provide the most useful basis for a pre-order review. Where supported by the host, link stability and diagnostic indications are reviewed together with the established link.
No. It is manufactured by HT under our own manufacturer identity.
Not necessarily. Both hosts must support the stated rate, identification, lane mapping and any required breakout configuration; mechanical compatibility alone is insufficient.
Provide the equipment manufacturer, model, port type, hardware revision and software release, together with the OEM reference, required length and quantity.
Protect both connector ends, keep the cable in a loose bend-safe coil and retain its part-number label so the length and compatibility identity remain traceable.
Standard configurations normally ship within one to three working days, while production quantities are confirmed with the order. Worldwide courier services are available, with air or sea freight for consolidated shipments; freight-collect delivery and coordination with a customer’s logistics provider can be arranged.
800G TransceiversOSFP and QSFP-DD modules for AI data center networks
400G QSFP-DDSR8, DR4, FR4 and LR4 modules and cables
100G QSFP28SR4, CWDM4, LR4 and ER4 transceivers
DAC CablesDirect attach copper cables from 10G up to 800G
AOC CablesActive optical cables for rack-to-rack links
MTP/MPO Trunk Cables8F to 144F multi fiber trunk and harness cables
Fiber Patch CablesOS2, OM3, OM4, OM5 jumpers with LC, SC, FC, ST connectors
Armored Patch CablesStainless steel tube protected fiber patch cords
UAE office: Abu Dhabi,Al khaleej Al Arabi
Factory add: ZYT industrial area, Shiyan, Baoan district, Shenzhen, China 518000