| Custom MTP-12 Armored Trunk Cable, 12-144 Fibers, OS2 |
![]() For UAE project teams, the key is to match this exact configuration to the port schedule, optical budget and delivery documentation. This configured-to-order trunk cable builds 12 to 144 OS2 9/125µm G.657.A1 fibers into a double-jacketed armored unit terminated with US Conec MTP Elite connectors. It brings the backbone-class 0.35dB maximum insertion loss of elite MTP terminations to routes that need real mechanical protection: between buildings, through industrial plant, or anywhere a trunk must survive the pathway instead of being protected by it. Product Highlights
Specifications
Armored trunk cabling for backbone linksBackbone trunks cross the most hostile pathways in a facility: riser shafts shared with power, inter-building conduits, plant rooms with moving machinery. The double-jacket armored build puts a helical steel tube around the fiber core, so this trunk carries the mechanical rating itself and the path does not depend on the condition of the conduit. MTP Elite performance and the loss budgetParallel-optic links chain multiple mated pairs, so per-connector loss decides whether the link closes. MTP Elite ferrules hold insertion loss to 0.35dB maximum with 0.15dB typical, roughly half the allowance of standard MTP terminations, which buys real headroom when the design stacks a trunk, two cassettes and patch patch cords end to end. Polarity: Type A, Type B and Type CMTP links must land transmit on receive, and this trunk polarity is how that is engineered. Type An is straight-through, Type B is reversed, Type C is pair-flipped; the proper option is determined by the cassette and duplex cord plan at the two ends. State the polarity method with the inquiry and this trunk is built and labeled to match it. Fiber counts from 12 to 144Base-12 build scales the identical trunk design from a single 12-fiber tube to 144 fibers in a 14.2mm double-jacketed build. Breakout legs are 2.0mm at 0.84m as standard, with pulling eyes and alternative leg arrangements offered on specify for long or difficult pulls. Pulling and installation practicesArmored trunks pull like a cable, not like a patch cord: respect the 200N long-term limit, use the pulling eye choice on long or conduit routes, and feed this trunk rather than dragging it around bends. The 10mm minimum bend radius of the G.657.A1 core is generous, but the practical limit on site is set by this trunk OD, so plan sweeps rather than right-angle turns at each direction change. Length options and customizationTrunks are built to the path: typical orders run from 1m (3ft) hardware-room links to 30m (98ft) and well beyond for inter-building pulls. Give the measured path with allowance for vertical drops and service loops, and the factory confirms the build and packing for the stated length. Quality control and testingEach MTP termination is interferometry-checked for end-face geometry, and every finished trunk is 100% insertion loss and return loss tested on all fibers, with results shipped against the serial number. The 0.35dB maximum and 65dB return figures are verified per mated pair, and the armor and jacket are inspected over the full trunk length. Ordering and Factory SupportSend the fiber count, connector gender per end, polarity type, jacket rating, path length and any breakout or pulling-eye needs. The factory returns a setup diagram with the quotation, and production starts once the diagram is approved. Our UAE project support can review the requirement with Shenzhen production before a formal quotation is issued. |
|||||||||||||||||||||||||||||||||||||||||||
Fiber Optic UAE supplies Custom MTP-12 Armored Trunk Cable, 12-144 Fibers, OS2 to data centers, ISPs and enterprises in Dubai, Abu Dhabi, Sharjah and across the Gulf region, with project support from our UAE office and production coordination from our Shenzhen factory.
UAE office: Abu Dhabi,Al khaleej Al Arabi
Factory add: ZYT industrial area, Shiyan, Baoan district, Shenzhen, China 518000