| LC to LC Duplex Armored Fiber Patch Cable, OS2, Riser (OFCR) |
![]() For UAE project teams, the key is to match this exact configuration to the port schedule, optical budget and delivery documentation. This duplex armored patch cable pairs two LC UPC connectors on an OS2 9/125µm single-mode unit protected by a helical stainless steel tube. The 3.0mm riser-rated (OFCR) jacket keeps this cable flexible sufficient for cabinet and under-floor routing while the steel armor absorbs crushing, pulling and rodent damage that would interrupt an ordinary patch cord. G.657.A1 bend-insensitive glass keeps attenuation stable even where the pathway turns tightly around trays and rack posts. Product Highlights
Specifications
Why steel armor instead of a conduitConventional patch patch cords depend on the surrounding duct or tray for mechanical protection. Where cables cross open floors, shared ceilings or industrial spaces, that protection is not always offered. Because the helical steel tube inside the assembly wraps the buffered fibers directly, this cable itself carries the crush and rodent resistance. Technicians may path it through areas that would otherwise require metal conduit, which reduces the two material cost and deployment time while keeping the pathway smaller and easier to reconfigure later. OS2 single-mode performance in duplex linksOS2 glass at 1310/1550nm supports the long-reach single-mode optics used in campus backbones, carrier access networks and data center interconnects. The duplex LC interface is the standard interface for SFP, SFP+, SFP28, QSFP+ and QSFP28 transceivers, so one cable series covers links from 1G through 100G and beyond. G.657.A1 bend tolerance is fully compatible with legacy G.652.D plant, which means this cable may be mixed into installed single-mode infrastructure without changing loss budgets. Understanding the OFCR riser ratingOFCR stands for optical fiber conductive riser: a riser-rated cable whose metallic armor makes it conductive under building codes. The riser rating permits vertical runs between floors in shafts and riser closets. Where the pathway passes through air-handling spaces, a plenum (OFNP) model should be chosen instead; where low smoke and zero halogen are specified, the LSZH version of this identical LC-LC build is offered. Matching the jacket to the building section is part of the ordering discussion, not an afterthought. Where armored duplex cords are deployedThe typical homes for this cord are data center cross-connect fields, campus backbone handoffs, industrial control rooms and any pathway shared with power cabling or foot traffic. In every case the pattern is the identical: the path is fixed, the cord is handled during each reconfiguration, and an unprotected jumper would eventually be crushed, kinked or chewed. The armored build removes that failure mode without changing how the cord dresses or connects. Length options and customizationStandard length options are stocked for fast delivery: 1m (3ft), 2m (7ft), 3m (10ft), 5m (16ft), 10m (33ft), 15m (49ft), 20m (66ft) and 30m (98ft), covering the common rack-to-rack, access and frame connections this cord is built for. Made-to-order lengths beyond this range are manufactured to order. The identical build may additionally be supplied with black or white jackets, APC polish, or alternative connectors through the custom duplex armored cable program. Specifying the precise path length avoids the two the slack storage problem of an overlong cord and the strain risk of one that is too short. Quality control and testingEach assembly is terminated with precision zirconia ferrule connectors and measured for insertion loss and return loss before packing. The 0.3dB insertion loss ceiling and 50dB minimum return loss are verified figures, not design targets. End-face geometry is checked to keep the physical contact consistent across repeat mating, and the ferrules are rated for up to one thousand insertion cycles, which matters in patching fields that are reconfigured frequently. Ordering and Factory SupportRefer to the LC-LC OS2 duplex armored series when ordering a quotation and state the path length, jacket rating and connector polish necessary. For non-standard combinations of length, color, connector or jacket, send the need with the inquiry and the factory will verify the manufacturable specification prior to production. Our UAE project support can review the requirement with Shenzhen production before a formal quotation is issued. |
|||||||||||||||||||||||||||||||
Fiber Optic UAE supplies LC to LC Duplex Armored Fiber Patch Cable, OS2, Riser (OFCR) to data centers, ISPs and enterprises in Dubai, Abu Dhabi, Sharjah and across the Gulf region, with project support from our UAE office and production coordination from our Shenzhen factory.
UAE office: Abu Dhabi,Al khaleej Al Arabi
Factory add: ZYT industrial area, Shiyan, Baoan district, Shenzhen, China 518000