Custom Simplex Armored Fiber Patch Cable, OS2, LC/SC/FC/ST/LSH
Custom Simplex Armored Fiber Patch Cable, OS2, LC/SC/FC/ST/LSH

For UAE project teams, the key is to match this exact configuration to the port schedule, optical budget and delivery documentation. This is the configured-to-order simplex armored platform: a single OS2 9/125µm G.657.A1 fiber inside a helical stainless steel tube, terminated with any mix of LC, SC, FC, ST or LSH connectors in UPC or APC polish, under a riser (OFCR), LSZH or plenum (OFNP) jacket in blue, black or white. It is the build for BiDi links, monitoring taps, test access and each other single-fiber application that stock patch cords do not quite match.

Product Highlights

  • Simplex OS2 9/125µm, built to the stated configuration
  • LC, SC, FC, ST or LSH connectors in any end-to-end mix
  • UPC or APC polish per end, return loss to 60/65dB class
  • Riser (OFCR), LSZH or plenum (OFNP) jacket, blue/black/white
  • Helical stainless steel armor, 120/225N tensile rating
  • Any length to order; standard range 1m to 30m stocked

Specifications

Connector TypeLC / SC / FC / ST / LSH, any end-to-end combination
Polish TypeUPC or APC per end
Fiber ModeOS2 9/125µm
Wavelength1310/1550nm
Fiber CountSimplex
PolarityA (Tx) to B (Rx)
Jacket ColorBlue / Black / White
Cable Outside Diameter (OD)3.0mm
Fiber GradeG.657.A1 (Compatible with G.652.D)
Min. Bend Radius (Fiber Cable)10/5D (Dynamic/Static)
Flame RatingRiser (OFCR) / LSZH / Plenum (OFNP)
Construction TypeSingle Armored, Stainless Steel Tube
Tensile Strength120/225N (Long/Short Term)
Insertion Loss≤0.3dB
Return LossUPC ≥50dB, APC ≥60dB (LC/SC/FC/ST); LSH APC ≥65dB
Operating TemperatureOFNP: 0 to 70°C; OFCR/LSZH: -20 to 70°C
Storage Temperature-40 to 70°C (-40 to 158°F)

Simplex configurations for BiDi and monitoring

Single-fiber transmission has become the default in access and increasingly in the data center: BiDi optics, WDM systems, monitoring taps and test access ports all light exactly one strand. A customized simplex cord matches that reality precisely, including hybrid builds such as LC UPC toward the transceiver and SC APC toward the distribution plant.

Connector and polish options

LC, SC, FC, ST and LSH bodies are all in the program, with UPC or APC polish selected per end. That covers the awkward one-offs that stall projects: a FC-equipped OTDR launch lead, an ST legacy panel, an LSH carrier frame, or an APC plant that must meet UPC hardware. Every combination is terminated and tested as a single unit.

Jacket, color and pathway

The jacket rating follows the building zone: riser (OFCR) for general and vertical pathways, LSZH for occupied public spaces, plenum (OFNP) for air-handling space. Blue is the standard single-mode color; black and white serve color-coded administration schemes or discreet routing in finished interiors. For UAE procurement, record this requirement with the project documents so the supplied configuration can be checked on arrival.

Test leads and launch cords

Customized simplex armored builds are frequently ordered as OTDR launch and receive leads, reference patch cords for loss test sets, and lab jumpers that get connected and disconnected all day. The armored tube protects the reference-grade termination from the handling that destroys ordinary lab patch cords, and the polish and connector may be matched exactly to the instrument and the plant under test.

Access-network repairs and restoration

Simplex armored customs are a practical restoration kit: when a drop tail or frame jumper is damaged, a hybrid replacement may be built to the precise failed combination and shipped without waiting for a distributor to stock the oddball. Keeping the failed connector types, polish and length in the trouble report is all the factory needs to verify the build, which turns a multi-day sourcing problem into a single inquiry.

Length options and customization

Standard length options are stocked for fast delivery: 1m (3ft), 2m (7ft), 3m (10ft), 5m (16ft), 10m (33ft), 15m (49ft), 20m (66ft) and 30m (98ft). Since each cord is built to order, any length between or beyond these sizes may be produced, which is how most access tails and test leads are actually specified.

Quality control and testing

Customized simplex patch cords are verified to the identical limits as the stock range: 0.3dB insertion loss ceiling and polish-suitable return loss measured on each assembly. APC ends are angle-verified, all ferrules are geometry-checked, and the tested figures ship with the batch documentation.

Ordering and Factory Support

Send this connector types and polish per end, the jacket rating, color and length. The factory confirms the manufacturable specification and lead time with the quotation; photos or drawings of the installed interfaces help avoid polish mismatches prior to production. Our UAE project support can review the requirement with Shenzhen production before a formal quotation is issued.

 

Fiber Optic UAE supplies Custom Simplex Armored Fiber Patch Cable, OS2, LC/SC/FC/ST/LSH to data centers, ISPs and enterprises in Dubai, Abu Dhabi, Sharjah and across the Gulf region, with project support from our UAE office and production coordination from our Shenzhen factory.


UAE Fiber Optics

UAE office: Abu Dhabi,Al khaleej Al Arabi
Factory add: ZYT industrial area, Shiyan, Baoan district, Shenzhen, China 518000

Popular Products

  • Fiber Optic Patch Cord
  • Fiber Optic Pigtail
  • Fiber Optic Attenuator
  • Fiber Optic Patch Panel
  • Fiber Optic Adapter

Products Datasheet

PDF catalogues of our products to download or for general inquiry, please send an email to sales@huihongfiber.com for details.

Customer Support

For customer support, please leave email to sales@huihongfiber.com, we shall reply to you as soon as possible.