SC to SC Duplex Armored Fiber Patch Cable, OM4, Riser (OFCR)
SC to SC Duplex Armored Fiber Patch Cable, OM4, Riser (OFCR)

For UAE project teams, the key is to match this exact configuration to the port schedule, optical budget and delivery documentation. This duplex armored patch cable fits SC UPC connectors on the two ends of an OM4 50/125µm multimode unit, with a helical stainless steel tube protecting the fibers under the aqua 3.0mm riser-rated (OFCR) jacket. It is built for installations where SC interfaces remain on the panels and hardware but the pathway demands real mechanical protection: open ceilings, industrial floors and shared risers.

Product Highlights

  • SC UPC to SC UPC duplex, OM4 50/125µm multimode
  • Helical stainless steel armor against crush, impact and rodents
  • Bend-insensitive OM4 fiber, 20/10D dynamic/static bend radius
  • Riser (OFCR) flame rating for vertical building pathways
  • Insertion loss ≤0.3dB, return loss ≥20dB
  • Stock lengths 1m to 30m; custom lengths and jackets on request

Specifications

Connector TypeSC to SC
Polish TypeUPC to UPC
Fiber ModeOM4 50/125µm
Wavelength850/1300nm
Fiber CountDuplex
Fiber GradeOM4 Bend Insensitive
Min. Bend Radius (Fiber Cable)20/10D (Dynamic/Static)
Cable Outside Diameter (OD)3.0mm
Flame RatingRiser (OFCR)
Construction TypeSingle Armored, Stainless Steel Tube
Tensile Strength120/225N (Long/Short Term)
Insertion Loss≤0.3dB
Return Loss≥20dB
Operating Temperature-20 to 70°C (-4 to 158°F)
Storage Temperature-40 to 70°C (-40 to 158°F)

SC duplex interfaces in panel and legacy environments

SC connectors remain common on wall-mounted enclosures, older fiber distribution frames, media converters and industrial Ethernet gear. The push-pull latching body tolerates frequent handling and is easy to seat with gloved hands, which is part of why SC persists in field-side cabling. This cord keeps that familiar interface while adding the steel armor those exposed environments normally demand.

OM4 bandwidth for short-reach optics

Behind the SC bodies the glass is full OM4: 10GBASE-SR to 400m, with headroom for 40G and 100G short-reach optics at row and room distances. For buildings that standardized on SC panels years ago, this makes it possible to upgrade connection speeds without re-terminating the fixed plant, as long as the link stays within the OM4 distance envelope.

Steel armor for exposed routing

SC-terminated links are frequently found exactly where cables get hurt: factory floors, campus outbuildings, temporary runs at events and build sites. The helical stainless tube inside the jacket wraps the buffered fibers directly, so the cord shrugs off crushing under floor tiles, accidental pulls and rodent damage. Technicians may cross areas that would otherwise call for conduit, keeping the path small and easy to change later.

Care of SC connectors in the field

SC ferrules are 2.5mm and easy to examine with standard tips and microscopes. clean the two end faces with a dry cassette cleaner and examine if the connection margin is tight; most "bad cord" reports in the field trace back to contamination rather than damage before connection. The push-pull housing ought to click positively; if it does not, review for dust caps left in this adapter rather than forcing the latch.

Length options and customization

Standard length options are stocked for fast delivery: 1m (3ft), 2m (7ft), 3m (10ft), 5m (16ft), 10m (33ft), 15m (49ft), 20m (66ft) and 30m (98ft), covering the common rack-to-rack, access and frame connections this cord is built for. Made-to-order lengths beyond this range are manufactured to order. Matching the cord length to the actual path keeps slack out of this panel and preserves the 850nm optical loss budget on longer multimode runs. Specifying the precise path length avoids the two the slack storage problem of an overlong cord and the strain risk of one that is too short.

Quality control and testing

Every SC-terminated unit is built with precision zirconia ferrules and tested for insertion loss and return loss before packing; the 0.3dB ceiling is verified on each cord. End-face geometry is checked for stable physical contact across repeat matings, and the SC housings are latch-tested for positive engagement.

Ordering and Factory Support

Reference against the SC-SC OM4 duplex armored series with the path length and jacket rating stated. Other connector mixes, polish types and jacket colors are offered through the custom duplex armored program once the factory confirms the requested specification. Our UAE project support can review the requirement with Shenzhen production before a formal quotation is issued.

 

Fiber Optic UAE supplies SC to SC Duplex Armored Fiber Patch Cable, OM4, Riser (OFCR) to data centers, ISPs and enterprises in Dubai, Abu Dhabi, Sharjah and across the Gulf region, with project support from our UAE office and production coordination from our Shenzhen factory.


UAE Fiber Optics

UAE office: Abu Dhabi,Al khaleej Al Arabi
Factory add: ZYT industrial area, Shiyan, Baoan district, Shenzhen, China 518000

Popular Products

  • Fiber Optic Patch Cord
  • Fiber Optic Pigtail
  • Fiber Optic Attenuator
  • Fiber Optic Patch Panel
  • Fiber Optic Adapter

Products Datasheet

PDF catalogues of our products to download or for general inquiry, please send an email to sales@huihongfiber.com for details.

Customer Support

For customer support, please leave email to sales@huihongfiber.com, we shall reply to you as soon as possible.