LC UPC to SC APC Duplex Armored Fiber Patch Cable, OS2, LSZH
LC UPC to SC APC Duplex Armored Fiber Patch Cable, OS2, LSZH

For UAE project teams, the key is to match this exact configuration to the port schedule, optical budget and delivery documentation. This duplex armored patch cable pairs flat-polished LC UPC connectors on one end with angled SC APC connectors on the other, on OS2 9/125µm single-mode fiber inside a helical stainless steel tube and a low smoke zero halogen jacket. It is built for carrier and access installations where LC-equipped optics must land on APC-terminated plant inside buildings that state LSZH cabling throughout.

Product Highlights

  • LC UPC to SC APC hybrid duplex, OS2 9/125µm single mode
  • LSZH jacket: low smoke, zero halogen in a fire
  • 8° APC polish on the plant end for ≥60dB-class return performance
  • Helical stainless steel armor against crush, impact and rodents
  • G.657.A1 bend-insensitive fiber, 10/5D bend radius
  • Stock lengths 1m to 30m; custom lengths and jackets on request

Specifications

Connector TypeLC to SC
Polish TypeUPC to APC
Fiber ModeOS2 9/125µm
Wavelength1310/1550nm
Fiber CountDuplex
Fiber GradeG.657.A1 (Compatible with G.652.D)
Min. Bend Radius (Fiber Cable)10/5D (Dynamic/Static)
Cable Outside Diameter (OD)3.0mm
Flame RatingLSZH (Low Smoke Zero Halogen)
Construction TypeSingle Armored, Stainless Steel Tube
Tensile Strength120/225N (Long/Short Term)
Insertion Loss≤0.3dB
Return Loss≥50dB (UPC) / ≥60dB (APC)
Operating Temperature-20 to 70°C (-4 to 158°F)
Storage Temperature-40 to 70°C (-40 to 158°F)

Duplex hybrid with APC on the plant end

PON and carrier access plant is terminated with angled APC connectors to keep reflections out of the setup, while the optics that feed it increasingly ship with LC ports. This cord bridges the two in a single tested duplex unit: LC UPC toward the active equipment, green-bodied SC APC toward the frame, with no adapter pair adding loss in the middle.

LSZH plus mixed polish for carrier access spaces

Central offices, metro PoPs and in-building access rooms increasingly fall under the identical low smoke zero halogen rules as public buildings. This cord satisfies the jacket specification and the reflection specification at once, so the compliance conversation does not force a compromise on either the jacket or the polish.

Armored for plant that gets worked on

Access frames and splitter cabinets are worked on constantly, and patch cords there are reseated, swung aside and redressed for years. The helical steel tube inside the LSZH jacket keeps the fibers safe through that service life, and the 3.0mm build still dresses through standard frame managers.

PON distribution inside buildings

In-building PON distribution concentrates at splitter cabinets on every floor or zone, and those cabinets sit in corridors and service rooms where LSZH is specified. This cord patches LC-based OLT or test ports to the APC splitter frame within the identical jacket policy as the rest of the floor. The armored build tolerates the constant re-dressing that splitter cabinets see as subscribers are added.

Length options and customization

Standard length options are stocked for fast delivery: 1m (3ft), 2m (7ft), 3m (10ft), 5m (16ft), 10m (33ft), 15m (49ft), 20m (66ft) and 30m (98ft), covering the common rack-to-rack, access and frame connections this cord is built for. Made-to-order lengths beyond this range are manufactured to order. Because in carrier rooms the frame location is fixed in the records, ordering to the documented path length keeps the slack storage inside design limits. Specifying the precise path length avoids the two the slack storage problem of an overlong cord and the strain risk of one that is too short.

Quality control and testing

Each assembly is terminated with precision zirconia ferrules; the APC end is angle-verified and the UPC end geometry-checked. Insertion loss and return loss are measured through the finished duplex cord before packing, so the 0.3dB insertion ceiling and the 50/60dB return figures are tested figures on the delivered unit.

Ordering and Factory Support

Reference against the LC UPC to SC APC OS2 LSZH armored series with the path length stated and the LSZH need referenced. Other hybrid combinations, including simplex versions, are offered in the identical jacket setup through the custom armored program. Our UAE project support can review the requirement with Shenzhen production before a formal quotation is issued.

 

Fiber Optic UAE supplies LC UPC to SC APC Duplex Armored Fiber Patch Cable, OS2, LSZH to data centers, ISPs and enterprises in Dubai, Abu Dhabi, Sharjah and across the Gulf region, with project support from our UAE office and production coordination from our Shenzhen factory.


UAE Fiber Optics

UAE office: Abu Dhabi,Al khaleej Al Arabi
Factory add: ZYT industrial area, Shiyan, Baoan district, Shenzhen, China 518000

Popular Products

  • Fiber Optic Patch Cord
  • Fiber Optic Pigtail
  • Fiber Optic Attenuator
  • Fiber Optic Patch Panel
  • Fiber Optic Adapter

Products Datasheet

PDF catalogues of our products to download or for general inquiry, please send an email to sales@huihongfiber.com for details.

Customer Support

For customer support, please leave email to sales@huihongfiber.com, we shall reply to you as soon as possible.